Background: The study assesses the feasibility of the DuoCor BiVAS, a novel biventricular assist system integrating magnetic levitation technology.
Methods: In an acute large animal model involving five sheep, each received the DuoCor BiVAS without cardiopulmonary bypass. Hemodynamic and device parameters were monitored continuously for 1-h post-implantation.
Background And Purpose: Flat-panel detector CT immediately after mechanical thrombectomy can detect complications, including early hemorrhagic transformation and subarachnoid hyperdensities. The clinical significance of subarachnoid hyperdensities in patients undergoing mechanical thrombectomy remains unclear.
Materials And Methods: We studied 223 patients who underwent mechanical thrombectomy for anterior circulation stroke who had flat-panel detector CT performed immediately after the procedure and had follow-up imaging within 24 hours.
Severe right heart failure, often overlooked and challenging to manage, has prompted a growing interest in innovative approaches to provide functional support. This study uses experimentation in large porcine models to introduce a novel prototype of a pulsatile mechanical circulatory support device and document its effects when deployed as a right ventricular assist device (RVAD). The pulsatile ventricular assist platform (pVAP), featuring a membrane pump driven by an intra-aortic balloon pump console, actively generates pulsatile flow to propel right ventricular blood into the pulmonary artery.
View Article and Find Full Text PDFBackground: Infective endocarditis (IE) poses a significant health risk, especially in patients with prosthetic heart valves. Despite advances in treatment, mortality rates remain high. This study aims to investigate the antibacterial properties of a copper titanium dioxide (4× Cu-TiO) coating on cardiovascular implants against Staphylococcus aureus, a common causative agent of IE.
View Article and Find Full Text PDFIn patients with left ventricular assist device (LVAD), infections and thrombotic events represent severe complications. We investigated device-specific local and systemic inflammation and its impact on cerebrovascular events (CVE) and mortality. In 118 LVAD patients referred for F-FDG-PET/CT, metabolic activity of LVAD components, thoracic aortic wall, lymphoid and hematopoietic organs, was quantified and correlated with clinical characteristics, laboratory findings, and outcome.
View Article and Find Full Text PDFMinimally invasive techniques have gained immense importance in cardiovascular surgery. While minimal access strategies for coronary and mitral valve surgery are already widely accepted and often used as standard approaches, the application of minimally invasive techniques is currently expanded towards more complex operations of the ascending aorta as well. In this new and developing field, various techniques have been established and reported ranging from upper hemisternotomy approaches, which allow even extensive operations of the ascending aorta to be performed through a minimally invasive access to sternal sparing thoracotomy strategies, which completely avoid sternal trauma during ascending aorta replacements.
View Article and Find Full Text PDFBackground: Transcriptomic data on bronchoalveolar lavage (BAL) from COVID-19 patients are currently scarce.
Objectives: This case series seeks to characterize the intra-alveolar immunopathology of COVID-19.
Method: BALs were performed on 14 patients (5 COVID-19, of which 3 mild and 2 largely asymptomatic, 9 controls).
We report here the first clinical use of the left atrial appendage (LAA) for epicardial micrograft transplantation during left ventricular assist device (LVAD) implantation. Previously, a sample from the right atrial appendage (RAA) has been available for processing and administering micrograft therapy in cardiac surgery. Both LAA and RAA are rich sources of various types of myocardial cells and are capable of providing both paracrine and cellular support to the failing myocardium.
View Article and Find Full Text PDFSpatial neglect is the dominant behavioral disorder after right hemisphere brain lesions. Reliabel diagnosis by formal neuropsychological testing is often achieved only later during hospitalization, leading to delays in targeted therapies. We propose a way to diagnose spatial neglect right at admission.
View Article and Find Full Text PDFThe field of quantum information processing offers secure communication protected by the laws of quantum mechanics and is on the verge of finding wider application for the information transfer of sensitive data. To improve cost-efficiency, extensive research is being carried out on the various components required for high data throughput using quantum key distribution (QKD). Aiming for an application-oriented solution, we report the realization of a multichannel QKD system for plug-and-play high-bandwidth secure communication at telecom wavelengths.
View Article and Find Full Text PDFJ Cardiovasc Surg (Torino)
February 2023
Background: Total artificial heart (TAH) implantation is a rarely performed procedure. Contrarily, left ventricular assist device (VAD) implantation is rather common in many centers. As transplantation is quantitatively limited cardiac replacement with artificial hearts is a viable alternative in the treatment of severe biventricular heart failure.
View Article and Find Full Text PDFBackground: Treatment of pertrochanteric femoral fractures is often associated with significant blood loss. It has already been demonstrated that the administration of tranexamic acid (TXA) for endoprosthetic procedures reduces blood losses and leads to a decreased frequency of postoperative complications. The aim of this study is to demonstrate whether the administration of TXA as part of osteosynthesis treatment for pertrochanteric fractures using a proximal femoral nail reduces perioperative blood losses and haemorrhage-related complications.
View Article and Find Full Text PDFBackground: Driveline (DL) damages are a common difficulty among ventricular assist devices (VAD). Repairing the electrical fibers inside the DL on a running pump is hazardous and requires technical expertise, which is not easily available on site. A new feature of the HeartMate3 (Abbott, U.
View Article and Find Full Text PDFBackground: In patients with left ventricular assist devices (LVADs), ischemic and hemorrhagic stroke are dreaded complications. Predictive markers for these events are lacking. This study aimed to investigate the prevalence and predictive value of microembolic signals (MES) for stroke, detected by Transcranial Doppler sonography (TCD) in patients with HeartMate 3 (HM 3) or HeartWare (HW).
View Article and Find Full Text PDFBackground: Peripartum cardiomyopathy (PPCM) is a rare cause of heart failure (HF), presenting with left ventricular (LV) systolic dysfunction either at the end of pregnancy or in the months following delivery. In rare cases, PPCM leads to severe impairment of LV function, refractory cardiogenic shock or advanced HF. LV assist devices (LVAD) have been shown to be a feasible treatment option in advanced HF.
View Article and Find Full Text PDFThe discovery of topological states of matter has led to a revolution in materials research. When external or intrinsic parameters break symmetries, global properties of topological materials change drastically. A paramount example is the emergence of Weyl nodes under broken inversion symmetry.
View Article and Find Full Text PDFObjectives: Historically, females were described as suffering from worse outcomes after left ventricular assist device (LVAD) implantation. However, females' preoperative conditions are unique, making direct comparisons with males challenging. This study aimed to select through propensity score (PS) matching two preoperatively comparable populations of females and males and test if any real sex-related difference exists regarding survival and adverse events after LVAD implantation.
View Article and Find Full Text PDFCardiorenal syndrome worsens outcome in patients with decompensated chronic heart failure, and complicates recompensation by medical therapy. Mechanical circulatory support has the potential to improve renal function, and likely mitigates diuretic resistance in patients with severe cardiorenal syndrome. The Reitan catheter pump (RCP) is a novel temporary percutaneous circulatory support system for reducing cardiac afterload and increasing renal preload.
View Article and Find Full Text PDFPatients undergoing explantation of left ventricular assist devices (LVADs) after improvement of myocardial function remain a minority. Nevertheless, considering the growing population of LVAD patients, increasing demand for new explantation strategies is expected. Herein, we present a retrospective review of seven patients undergoing HeartMate3 explantation with the use of a custom-made apical ring plug in four medical centers.
View Article and Find Full Text PDF