Background: Recurrent patellar dislocation is the result of anatomical alignment and imbalance of restraint of bone and soft tissue. We investigate the anatomical characteristics of the knee joint in a family of patients with recurrent patella dislocation, and to screen the possible pathogenic genes in this family by whole exome sequencing in 4 patients and 4 healthy subjects, so as to provide theoretical basis for the pathogenesis of this disease.

Methods: The data related to patella dislocation were measured by imaging data.

View Article and Find Full Text PDF

The reciprocate scanning scheme of two-dimensional galvanometers is widely used in laser confocal scanning microscopes with high speed. However, the equal interval acquisition of an analog digital acquisition card (AD) and the unequal change of the galvanometer's scanning speed will cause the dislocation of pixels and distortion of the reconstructed image. Meanwhile, the movement properties of the galvanometers in the edge of the scanning area are complex, which will increase the difficulty of segmenting the collected one-dimensional data stream the AD collected into row data of a two-dimensional reconstructed image.

View Article and Find Full Text PDF

In order to smooth the spectra automatically and reliably, a spectral smoothing algorithm with adaptive multiscale window average (AWMA) is demonstrated. In this method, different positions of the spectra are smoothed by windows of different width, and the width of the windows will directly affect smoothing. The window with inappropriate width may cause excessive denoising (peak distortion or loss) or inadequate denoising (the flat region of the spectra still contains a lot of noise).

View Article and Find Full Text PDF

The baseline correction is an, extremely important spectral preprocessing step and can significantly improve the accuracy of the subsequent spectral analysis algorithm. At present most of the baseline correction algorithms are manual and semi-automated. The manual baseline correction depends on the user experience and its accuracy is greatly affected by the subjective factor.

View Article and Find Full Text PDF

The projection algorithm used in mixture analysis to determine whether there is unknown disturbance existing in grey system can not accurately identify different samples and similar samples at the same time when it is used in the identification of drugs, because of the insufficient criteria. In the present study, one of its criteria for whether the size of measurement error of testing sample is at a limited level is improved for whether the size and distribution of measurement error is equal and similar between testing sample and standard sample. By testing 6 kinds of normal drugs (including BAYER Aspirin Enteric-coated Tablets, TYLENOL Acetaminophen Sustained Release Tablets, BAYER Compound Paracetamol Tablets(II), HUAZHONG Compound Vitamin C, HUAZHONG Vitamin B and MADINGLIN Demperidone Tablets) and 3 kinds of similar drugs of aspirin (including BAYER Aspirin Enteric-coated Tablets, Shanghai SINE Aspirin Enteric-coated Tablets and Bamyl Aspirin Effervescent Tablets), it was found that the un-improved projection algorithm directly used in discrimination of drugs shows poor performance with many problems existing, however, the improved projection algorithm can discriminate different drugs and similar drugs with accuracy up to 100%.