Background: Counseling of Implantable Cardioverter-defibrillator (ICD) patients with regard to individual risks and benefits is challenging. An evidence-based decision aid tailored to the needs of Dutch ICD patients is not yet available. The objective of this pilot project was to structurally evaluate the current clinical practice in The Netherlands and the ICD patient experience, in order to develop an online decision aid to facilitate shared decision making in ICD procedures.
View Article and Find Full Text PDFEuropace
June 2021
Aims: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation.
Methods And Results: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively.
Aims: The BRIGHT study evaluated bifocal right ventricular (RV) (apex and outflow tract) pacing in a single, blind, randomized crossover study in patients eligible for cardiac resynchronization therapy (CRT). Forty-two patients were enrolled with the following characteristics: chronic drug refractory heart failure New York Heart Association (NYHA) class III-IV; ejection fraction (EF)<35%; QRS width >or= 120 ms; and a left bundle branch block. The aim of the study was to assess an improvement in left ventricular (LV) EF, 6 min walk test, Minnesota quality-of-life score, and NYHA classification.
View Article and Find Full Text PDFAims: The characteristics of sensors to perform rate adaptive pacing are well established but whether their contribution improves health-related quality of life (QoL) remains disputable. To compare the effects on QoL with an integrated dual sensor [minute ventilation (MV) and acceleration, TT sensor] with a single MV sensor, and with no rate adaptive pacing.
Methods And Results: This Dutch multi centre, prospective, single- (patient) blind study was performed in patients after first pacemaker (PM) implant for sick sinus syndrome or AV block.
We present a case of a 55-year-old men who suffered a silent myocardial infarction four years earlier and presented with exertional dyspnoea. Cardiac magnetic resonance imaging (CMR) and Multislice computed tomography (MSCT) was performed and revealed a giant pseudoaneursym of the lateral wall of the left ventricle with the presence of a thrombus in the lateral wall of the pseudoaneursym. We present this case since excellent non-invasive evaluation of the pseudoaneursym was feasible using state-of-the-art imaging modalities.
View Article and Find Full Text PDF