Background: Thrombosis of the vascular access in patients with end-stage renal disease requiring hemodialysis are common and require timely interventional procedures to restore patency. The aim of the current study was to identify factors having a significant effect on patency rates after access thrombosis. Our hypothesis was the length of time between the initial clotting of the access and the subsequent percutaneous declotting impacts the patency rates of the vascular access.
View Article and Find Full Text PDFIntroduction: Coronavirus disease (COVID-19) is a global pandemic which continues to cause systemic inflammation, leading to multi-system organ damage including acute kidney injury (AKI) and thrombotic complications. We hypothesize that D-dimer level predicts an increased risk of AKI and thrombotic complications in COVID-19.
Methods: This was a retrospective cohort study performed at a single-center academic center.
Comput Struct Biotechnol J
October 2022
End-Stage Renal Disease (ESRD) patients require arteriovenous fistulas (AVF) that allow a mature vein to withstand hemodialysis. Unfortunately, venous thrombosis and stenosis in the cephalic vein arch after AVF placement is common and heavily influenced by hemodynamics. To better assess forces and flow behavior in the cephalic arch, we have built patient-specific millifluidic models that allow us to explore the complex interplay between patient-specific vein geometry and fluctuating hemodynamics.
View Article and Find Full Text PDFObjectives: The number of women with opioid-related diagnoses in the United States has significantly increased in recent decades, resulting in concomitantly higher rates of infants born with neonatal opioid withdrawal syndrome (NOWS). Addressing prenatal opioid exposure is a priority for Alaska health systems. The objectives of this study were to: (1) identify maternal and neonatal factors associated with receipt of Medication for opioid use disorder (MOUD) and (2) determine the impact of prenatal MOUD on discharge to parents among infants with NOWS in 3 Alaska hospitals.
View Article and Find Full Text PDFBackground: Arteriovenous fistula (AVF) creation and maturation for hemodialysis is globally a topic of importance given the poor results and high costs associated with renal care. Successful AVF (surgical or endovascular) creation requires appropriate superficial veins and quality arteries. Many procedures fail due to initial small veins with limited blood flow capacity and distensibility.
View Article and Find Full Text PDFBackground: The most common configuration for arteriovenous fistula is brachiocephalic which often develop cephalic arch stenosis leading to the need for numerous procedures to maintain access patency. The hemodynamics that contributes to the development of cephalic arch stenosis is incompletely understood given the inability to accurately determine shear stress in the cephalic arch. In the current investigation our aim was to determine pressure, velocity and wall shear stress profiles in the cephalic arch in 3D using computational modeling as tools to understand stenosis.
View Article and Find Full Text PDFBackground: Acupuncture is used to treat patients with diabetic peripheral neuropathy; however, the evidence is unclear. We present the design and methodology of the ACUDPN (ACUpuncture in Diabetic Peripheral Neuropathy) trial, which investigates the effectiveness of acupuncture for the treatment of diabetic peripheral neuropathy (DPN) symptoms. The aim of this study is to investigate whether acupuncture is effective for the treatment of DPN symptoms.
View Article and Find Full Text PDFIntegr Psychol Behav Sci
June 2021
Ten female and five male participants (age range 28-50 years) were recruited at esoteric fairs or via esoteric chatrooms. In a guided face-to-face interview, they reported origins and contents of their beliefs in e.g.
View Article and Find Full Text PDFBackground: A brachiocephalic fistula is frequently placed for hemodialysis; unfortunately, cephalic arch stenosis commonly develops, leading to failure. We hypothesized that a contribution to brachiocephalic fistula failure is low wall shear stress resulting in neointimal hyperplasia leading to venous stenosis. The objective of this investigation is to determine correspondence of low wall shear stress and the development of cephalic arch stenosis.
View Article and Find Full Text PDFPurpose: Arteriovenous fistulas and grafts, necessary for hemodialysis, may develop stenoses due to neointimal hyperplasia, which often require percutaneous transluminal angioplasty. Patient and lesion characteristics were evaluated prior to angioplasty and were correlated with 1- and 6-month outcomes.
Materials And Methods: This was an observational study of African American hemodialysis patients who presented for angioplasty of a dysfunctional fistula or graft.
J Med Eng Technol
November 2018
The surgical creation of an artery-vein connection via a Brachicephalic fistula (BCF) in patients with end stage renal disease (ESRD) provides a unique opportunity to study blood vessel response mechanisms to extreme hemodynamic conditions in relatively short timeframes. After BCF creation, the flow rate in the vein increases by an order of magnitude leading to separated flows and corresponding abnormally low, or negative, wall shear stress (WSS) in the curved arch segment of the cephalic vein. Locations of abnormally low WSS are shown to correlate with development of neointimal hyperplasia (NH) and subsequent stenosis.
View Article and Find Full Text PDFBackground: Hepatitis C virus (HCV)-infected organs are being transplanted in patients with and without HCV in the direct-acting antiviral era. Little is known about patient attitudes towards receiving an HCV-positive organ.
Objectives: The aim of this study is to determine transplant candidates' attitudes towards receiving HCV-positive organs.
Aim: Arteriovenous fistulas (AVF) are the optimal vascular access for hemodialysis although many fistulas fail. The impetus to increase hemodialyzer blood flow (QB) in order to maximize solute clearances may be counterbalanced if AVF suffer adverse hemodynamic effects from accelerated pump flows. The optimal QB to maintain adequate hemodialysis without potentially contributing to AVF dysfunction is unknown.
View Article and Find Full Text PDFHigh flow arteriovenous fistulas are a common clinical entity affecting patients with end-stage renal failure receiving hemodialysis. Given the difficulty in predicting who will develop a high flow arteriovenous fistula the exact prevalence is unclear. We present two cases of patients with high flow arteriovenous fistula that developed clinical cardiac failure at a time point after the fistula was placed with findings of significant cephalic arch stenosis.
View Article and Find Full Text PDFBackground: Vascular access for hemodialysis is best provided by an arteriovenous fistula (AVF). AVF fail primarily because of neointimal hyperplasia. Asymmetric dimethlyarginine (ADMA) is a naturally occurring analogue of L-arginine, which is elevated in renal failure and impairs endothelial cell function.
View Article and Find Full Text PDFComput Methods Appl Mech Eng
July 2017
The surgical creation of vascular accesses for renal failure patients provides an abnormally high flow rate conduit in the patient's upper arm vasculature that facilitates the hemodialysis treatment. These vascular accesses, however, are very often associated with complications that lead to access failure and thrombotic incidents, mainly due to excessive neointimal hyperplasia (NH) and subsequently stenosis. Development of a framework to monitor and predict the evolution of the venous system post access creation can greatly contribute to maintaining access patency.
View Article and Find Full Text PDFGiven the current emphasis on accurate computational fluid dynamics (CFD) modeling of cardiovascular flows, which incorporates realistic blood vessel geometries and cardiac waveforms, it is necessary to revisit the conventional wisdom regarding the influences of non-Newtonian effects. In this study, patient-specific reconstructed 3D geometries, whole blood viscosity data, and venous pulses postdialysis access surgery are used as the basis for the hemodynamic simulations of renal failure patients with native fistula access. Rheological analysis of the viscometry data initially suggested that the correct choice of constitutive relations to capture the non-Newtonian behavior of blood is important because the end-stage renal disease (ESRD) patient cohort under observation experience drastic variations in hematocrit (Hct) levels and whole blood viscosity throughout the hemodialysis treatment.
View Article and Find Full Text PDFBackground: An autogenous arteriovenous fistula is the optimal vascular access for hemodialysis. In the case of brachiocephalic fistula, cephalic arch stenosis commonly develops leading to access failure. We have hypothesized that a contribution to fistula failure is low wall shear stress resulting from post-fistula creation hemodynamic changes that occur in the cephalic arch.
View Article and Find Full Text PDF