Pneumothorax resulting from injury is a common phenomenon in both civilian and military trauma. A pneumothorax or simple pneumothorax is defined as air in the pleural space. A tension pneumothorax can evolve from a simple pneumothorax if there is a continued air leak from the lung without mechanism for egress.
View Article and Find Full Text PDFBackground: Today, with wars raging in Ukraine and the Middle East, the demand for blood is high. Despite this, few companies produce the necessary equipment to draw, store, and transfuse whole blood. This study evaluated the safety and performance of a 3D printed bottle cap in conjunction with a water bottle and some available consumables to draw and store fresh whole blood.
View Article and Find Full Text PDFIntroduction: Limb and junctional hemorrhage are leading causes of potentially preventable death among trauma casualties. Hemorrhage control for these regions could be achieved by direct or indirect pressure. The manual pressure points (MPP) involves applying manual pressure on the arterial supply to occlude distal blood flow without the need for specialized equipment.
View Article and Find Full Text PDFBased on limited published evidence, physiological principles, clinical experience, and expertise, the author group has developed a consensus statement on the potential for iatrogenic harm with rapid sequence induction (RSI) intubation and positive-pressure ventilation (PPV) on patients in hemorrhagic shock. "In hemorrhagic shock, or any low flow (central hypovolemic) state, it should be noted that RSI and PPV are likely to cause iatrogenic harm by decreasing cardiac output." The use of RSI and PPV leads to an increased burden of shock due to a decreased cardiac output (CO)2 which is one of the primary determinants of oxygen delivery (DO2).
View Article and Find Full Text PDFScand J Trauma Resusc Emerg Med
August 2020
Background: The measurement of lactate in emergency medical services has the potential for earlier detection of shock and can be performed with a point-of-care handheld device. Validation of a point-of-care handheld device is required for prehospital implementation.
Aim: The primary aim was to validate the accuracy of Lactate Pro 2 in healthy volunteers and in haemodynamically compromised intensive care patients.
Background: The success of implementing damage control resuscitation principles pre-hospital has been at the expense of several logistic burdens including the requirements for resupply, and the question of donor safety during the development of whole blood programs. Previous studies have reported effects on physical performance after blood donation; however, none have investigated the effects of blood donation on cognitive performance.
Method: We describe a prospective double-blinded, randomized, controlled study comprised of a battery of tests: three cognitive tests, and VO2max testing on a cycle ergometer.
Background: Intraosseous (IO) vascular access is increasingly used as an emergency tool for achieving access to the systemic circulation in critically ill patients. The role of IO transfusion of blood in damage control resuscitation is however questionable due to possible inadequate flow rate and hemolysis. Some experts claim that IO transfusion is contraindicated.
View Article and Find Full Text PDFHemorrhagic shock is both a local and systemic disorder. In the context of systemic effects, blood loss may lead to levels of reduced oxygen delivery (DO2 ) sufficient to cause tissue ischemia. Similar to other physiologic debts such as sleep, it is not possible to incur a significant oxygen debt and suffer no consequences for lack of timely repayment.
View Article and Find Full Text PDFBackground: To provide whole blood on the battlefield can be a challenge, but a buddy system protocol is both an elegant and the only currently available means to supply blood to a Special Forces team in far-forward locations. Our aim was to investigate donor-safety associated with such a protocol.
Methods: This study was a randomized, double-blinded, controlled trial that aimed to evaluate the immediate effects of a 450 cc blood donation on physical performance in fatigued and dehydrated Special Forces soldiers.
In planning for future contingencies, current problems often crowd out historical perspective and planners often turn to technological solutions to bridge gaps between desired outcomes and the reality of recent experience. The US Military, North Atlantic Treaty Organization, and other allies are collectively taking stock of 10-plus years of medical discovery and rediscovery of combat casualty care after the wars in Iraq and Afghanistan. There has been undeniable progress in the treatment of combat wounded during the course of the conflicts in Southwest Asia, but continued efforts are required to improve hemorrhage control and provide effective prehospital resuscitation that treats both coagulopathy and shock.
View Article and Find Full Text PDFThe optimal resuscitation fluid for uncontrolled bleeding and hemorrhagic shock in both pre- and in-hospital settings has been an ongoing controversy for decades. Hemorrhage continues to be a major cause of death in both the civilian and military trauma population, and survival depends on adequacy of hemorrhage control and resuscitation between onset of bleeding and arrival at a medical treatment facility. The terms far-forward and austere are defined, respectively, as the environment where professional health care providers normally do not operate and a setting in which basic equipment and capabilities necessary for resuscitation are often not available.
View Article and Find Full Text PDFMilitary experience and recent in vitro laboratory data provide a biological rationale for whole-blood use in the treatment of exsanguinating hemorrhage and have renewed interest in the reintroduction of fresh whole blood and cold-stored whole blood to patient care in austere environments. There is scant evidence to support, in a field environment, that a whole blood-based resuscitation strategy is superior to a crystalloid/colloid approach even when augmented by a limited number of red blood cell (RBC) and plasma units. Recent retrospective evidence suggests that, in this setting, resuscitation with a full compliment of RBCs, plasma, and platelets may offer an advantage, especially under conditions where evacuation is delayed.
View Article and Find Full Text PDFThe Blood Far Forward (BFF) research program was established to conduct blood product efficacy and safety studies, donor performance studies, and research on optimal training methods to improve the safety of blood collection and transfusion performed by Norwegian Naval Special Operation Commando soldiers. The use of intravenous fluids for volume replacement during hemorrhagic shock is controversial, but it is currently the standard of care. In the far-forward environment, large volume resuscitation for massive bleeding is a great challenge.
View Article and Find Full Text PDF