Background: Blood flow to the brain is a critical physiological function and is useful to monitor in critical care settings. Despite that, a surrogate is most likely measured instead of actual blood flow. Such surrogates include velocity measurements in the carotid artery and systemic blood pressure, even though true blood flow can actually be obtained using MRI and other modalities.
View Article and Find Full Text PDFBackground: Recent studies describe an emerging role for percutaneous left ventricular assist devices such as Impella CP® as rescue therapy for refractory cardiac arrest. We hypothesized that the addition of mechanical chest compressions to percutaneous left ventricular assist device assisted CPR would improve hemodynamics by compressing the right ventricle and augmenting pulmonary blood flow and left ventricular filling. We performed a pilot study to test this hypothesis using a swine model of prolonged cardiac arrest.
View Article and Find Full Text PDFBackground: It remains unclear if percutaneous left ventricular assist device (pLVAD) reduces post-cardiac arrest myocardial dysfunction.
Methods: This is a prespecified analysis of a subset of swine that achieved return of spontaneous circulation (ROSC) in a study comparing pLVAD, transient aortic occlusion (AO), or both during cardiopulmonary resuscitation (CPR). Devices were initiated after 24 minutes of ventricular fibrillation cardiac arrest (8 min no-flow and 16 min mechanical CPR).
Objectives: Transcranial Doppler (TCD) has been evaluated as a noninvasive intracranial pressure (ICP) assessment tool. Correction for insonation angle, a potential source of error, with transcranial color-coded sonography (TCCS) has not previously been reported while evaluating ICP with TCD. Our objective was to study the accuracy of TCCS for detection of ICP elevation, with and without the use of angle correction.
View Article and Find Full Text PDFThe status of peripheral arteries is known to be a key physiological indicator of the body's response to both acute and chronic medical conditions. In this paper, peripheral artery deformation is tracked by wearable photoplethysmograph (PPG) and piezo-electric (polyvinylidene difluoride, PVDF) sensors, under pressure-varying cuff. A simple mechanical model for the local artery and intervening tissue captures broad features present in the PPG and PVDF signals on multiple swine subjects, with respect to varying cuff pressure.
View Article and Find Full Text PDFObjective: Our objective was to analyze and compare out-of-hospital cardiac arrest (OHCA) system of care performance and outcomes at the Medical Control Authority (MCA) level in the state of Michigan. We hypothesized that clinically and statistically significant variations in treatment and outcomes of OHCA exists within a single U.S.
View Article and Find Full Text PDFIntroduction: Oxidation-reduction reactions involve electron exchanges that require optimal balance for proper cell function. This balance is measured via redox potential and reflects oxidative stress. Despite the critical role of oxidative stress in critical illness and injury, little is known regarding redox potential.
View Article and Find Full Text PDFBackground: Gaining hemostatic control of lethal vascular injuries sustained in combat using topical agents remains a challenge. Recent animal testing using a lethal arterial injury model has demonstrated that QuikClot zeolite granules (QCG) and the HemCon chitosan bandage (HC) are not capable of providing hemostasis and improving survival over the Army gauze field bandage (AFB). We have developed a new hemostatic agent consisting of a granular combination of a smectite mineral and a polymer (WoundStat) capable of producing hemostasis in the face of high-pressure arterial bleeding.
View Article and Find Full Text PDFResonance Raman spectroscopy offers a mechanism for the noninvasive measurement of in vivo and in situ hemoglobin oxygen saturation (HbO(2)Sat) in living tissue. Clinically informative signals can be provided by resonance enhancement with deep violet excitation. It is notable that fluorescence does not significantly degrade the quality of the signals.
View Article and Find Full Text PDFObjective: This pilot study tested the potential of puromycin (PUR) to inhibit protein synthesis and reduce oxygen utilization in a non-hibernating, whole animal preparation.
Methods: After anesthesia and instrumentation, male rats received a single dose of PUR or 0.9% saline (control), followed 60 min later with [(35)S] methionine/cysteine radiolabeling.
Unlabelled: Knowledge of central venous pressure (CVP) is considered valuable in the assessment and treatment of various states of critical illness and injury.
Objectives: We tested a noninvasive means of determining CVP (NICVP), by monitoring forearm volume changes in response to externally applied circumferential pressure to the upper arm veins.
Methods: Sixteen patients who were undergoing CVP monitoring as a part of their care had NICVP determined and compared with CVP.
This study describes the implantation of transit-time flow probes on the ascending aorta of rats while minimizing the risk of postoperative complications. Special emphasis is placed on our new method of rat intubation as well as the production of materials necessary for the implantation procedure such as endotracheal tubes and heparin bonded vessel catheters. The effects of these devices on the response to acute hypoxia were studied in rats following a 5-7 day recovery from the implantation procedure.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
November 2004
We tested the hypotheses that continuous total peripheral resistance (TPR) measurements are superior to intermittent data collection and that variables related to TPR can be used to distinguish between survivors and nonsurvivors (NS), respectively, of prolonged hemorrhagic hypotension (HH). One week after a transit-time ultrasound probe was implanted on their ascending aortas, 21 rats were subjected to 4 h of HH at 40 mmHg. Measurements were made before and up to 4 h after initiation of HH.
View Article and Find Full Text PDFStudies are needed to provide a rigorous examination of the relevance of monitored variables during prolonged hemorrhagic hypotension (HH). This study was designed to investigate the parameters that describe biochemical and O2 transport patterns in animals subjected to HH. Systemic parameters that could differentiate survivors from nonsurvivors were identified.
View Article and Find Full Text PDF