Publications by authors named "Haitao Liao"

Biology remains the envy of flexible soft matter fabrication because it can satisfy multiple functional needs by organizing a small set of proteins and polysaccharides into hierarchical systems with controlled heterogeneity in composition and microstructure. Here, it is reported that controlled, mild electronic inputs (<10 V; <20 min) induce a homogeneous gelatin-chitosan mixture to undergo sorting and bottom-up self-assembly into a Janus film with compositional gradient (i.e.

View Article and Find Full Text PDF

Janus porous biomaterials are gaining increasing attention and there are considerable efforts to develop simple, rapid, and scalable methods capable of tuning micro- and macro-structures. Here, a single-step electro-fabrication method to create a Janus porous film by the electrodeposition of the amino-polysaccharide chitosan is reported. Specifically, a Janus structure emerges spontaneously when electrodeposition is performed at sub-ambient temperature (0-5 °C).

View Article and Find Full Text PDF

Background: Multi-modal neuroimaging with appropriate atlas is vital for effectively differentiating mild cognitive impairment (MCI) from healthy controls (HC).

Methods: The resting-state functional magnetic resonance imaging (rs-fMRI) and structural MRI (sMRI) of 69 MCI patients and 61 HC subjects were collected. Then, the gray matter volumes obtained from the sMRI and Hurst exponent (HE) values calculated from rs-fMRI data in the Automated Anatomical Labeling (AAL-90), Brainnetome (BN-246), Harvard-Oxford (HOA-112) and AAL3-170 atlases were extracted, respectively.

View Article and Find Full Text PDF

Two dithienocyclopentafluorene-based small-molecule acceptors (SMAs) were developed that feature methylene-functionalized conjugated side chains, to study the effect of arylmethylene substitution and its number on structure, optoelectronic properties and device performance. Results showed that two SMAs have better absorption properties and planarity, lower bandgaps and higher LUMOs compared with the control SMA without conjugated side chains. The synthesized SMAs were tested in polymer solar cells for examples of their applicability.

View Article and Find Full Text PDF

Purpose: The purpose of our study was to investigate the association between cardiopulmonary bypass (CPB) duration and the incidence of pressure injuries (PIs) in patients undergoing cardiovascular surgery.

Design: Retrospective chart review.

Subjects And Setting: Two hundred and eighty-eight patients who underwent cardiovascular surgery with CPB from January 2016 through December 2016 in a 2000-bed general hospital, which integrates medical service, education, and research and in which 300 to 350 cardiovascular surgical procedures with CPB are performed each year.

View Article and Find Full Text PDF

Rational design of artificial microstructured metamaterials with advanced mechanical and physical properties that are not accessible in nature materials is very important. Making use of node rotation and ligament bending deformation features of chiral materials, two types of innovative 3D chiral metamaterials are proposed, namely chiral- chiral- antichiral and chiral- antichiral- antichiral metamaterials. In-situ compression and uniaxial tensile tests are performed for studying the mechanical properties and deformation mechanisms of these two types of 3D chiral metamaterials.

View Article and Find Full Text PDF

Accelerated degradation testing (ADT) is an efficient technique for evaluating the lifetime of a highly reliable product whose underlying failure process may be traced by the degradation of the product's performance parameters with time. However, most research on ADT mainly focuses on a single performance parameter. In reality, the performance of a modern product is usually characterized by multiple parameters, and the degradation paths are usually nonlinear.

View Article and Find Full Text PDF

Multichannel sensor systems are widely used in condition monitoring for effective failure prevention of critical equipment or processes. However, loss of sensor readings due to malfunctions of sensors and/or communication has long been a hurdle to reliable operations of such integrated systems. Moreover, asynchronous data sampling and/or limited data transmission are usually seen in multiple sensor channels.

View Article and Find Full Text PDF