Cystatin C (CysC) belongs to the cysteine protease inhibitor superfamily and is produced by all nucleated cells in the body in very stable amounts independent of age, sex, diet, and muscle mass. CysC is considered an ideal biomarker for assessing glomerular filtration rate (GFR) compared to traditional biomarkers for assessing GFR, such as creatinine. However, CysC is not sufficiently utilized for GFR assessment by clinicians, probably for various reasons such as insufficient understanding among clinicians or a lack of standardized quantitative methods.
View Article and Find Full Text PDFObjective: To investigate the diagnostic value of D-dimer, platelet-lymphocyte rate (PLR) and CT signs for intestinal ischemia in patients with bowel obstruction.
Methods: We retrospectively analyzed the clinical and imaging data of 105 patients diagnosed with bowel obstruction, and performed univariate and multivariate analyses to determine the independent risk factors for intestinal ischemia in patients with bowel obstruction. Moreover, the receiver operating characteristic curve (ROC) was plotted to examine the diagnostic value of D-dimer, PLR and CT signs in patients with bowel obstruction.
Objectives: Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients.
Methods: Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems.
Background: This study assessed the alternations of kynurenine pathway (KP) and neopterin in type 2 diabetes mellitus (T2DM) and explored possible differential metabolites.
Methods: A fresh residual sera panel was collected from 80 healthy control (HC) individuals and 72 T2DM patients. Metabolites/ratios of interest including tryptophan (TRP), kynurenine (KYN), 5-hydroxytryptamine (5HT), kynurenic acid (KA), xanthurenic acid (XA), neopterin (NEO), KA/KYN ratio and KYN/TRP ratio were determined using a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) metabolomics approach, and the difference between groups was assessed.
BACKGROUND Previous studies have shown that systemic inflammation and suboptimal nutritional status are associated with poor cancer prognosis. This study aims to investigate the prognostic value of preoperative Glasgow prognostic score (GPS) and fibrinogen-to-prealbumin ratio (FPR) in patients with CRC (colorectal cancer) after laparoscopic surgery. MATERIAL AND METHODS In this study, the clinical data of 112 patients with CRC who underwent laparoscopic surgery were retrospectively analyzed, and the 3-year and 5-year survival rates of these patients were evaluated.
View Article and Find Full Text PDFBackground: Abnormal bile acid metabolism leading to changes in placental function during pregnancy. To determine whether endoplasmic reticulum protein 29 (ERp29) can mediate the pregnancy effects of cholestasis by altering the level of trophoblast cell apoptosis.
Methods: ERp29 in serum of 66 intrahepatic cholestasis of pregnancy (ICP) pregnant women and 74 healthy were detected by ELISA.
Objective: This study aims to investigate the effect of red ginseng polysaccharide (RGP) on gastric cancer (GC) development and explore its mechanism.
Methods: GC cell lines AGS were treated with varying concentrations of RGP (50, 100, and 200 μg/mL). AGS cells treated with 200 μg/mL RGP were transfected with aquaporin 3 (AQP3) overexpression vector.
Background: Clinical chemistry tests are most widely used in clinical laboratories, and diverse measurement systems for these analyses are available in China. We evaluated the imprecision of clinical chemistry measurement systems based on internal QC (IQC) data.
Methods: IQC data for 27 general chemistry analytes were collected in February each year from 2013 to 2022.
Objectives: To find suitable external quality assessment (EQA) materials for serum C-peptide, we evaluated the commutability of five types of processed materials.
Methods: Seventy-four individual serum samples and 12 processed samples including three EQA samples currently in use, frozen human serum pools (FHSP), and three other kinds of processed samples were prepared by dissolving WHO International Standard Reagent for C-peptide (WHO ISR 13/146) in three different matrixes: 0.05 % bovine serum albumin, fetal bovine serum and human serum pools.
BACKGROUND Studies have revealed that having systemic inflammation is linked to worse survival rates across a range of malignancies. This study aimed to evaluate the predictive significance of neutrophil-to-lymphocyte ratio (NLR), platelet-to-lymphocyte ratio (PLR), and lymphocyte-to-monocyte ratio (LMR) in combination with fibrinogen-to-albumin ratio (FAR) in surgical patients with colorectal adenocarcinoma (CRC). MATERIAL AND METHODS From January 2010 to December 2016, 200 patients with CRC had their preoperative NLR, PLR, LMR, and FAR assessed.
View Article and Find Full Text PDFObjectives: Except for the large bias of some measurement systems for serum cystatin C (CysC) measurements, unacceptable imprecision has been observed for the heterogenous system. This study analyzed the external quality assessment (EQA) results in 2018-2021 to provide an insight into the imprecision of CysC assays.
Methods: Five EQA samples were sent to participating laboratories every year.
Background: Serum C-peptide results from various routine methods used in China are highly variable, warranting well-performing methods to serve as an accuracy base to improve the harmonization of C-peptide measurements in China. We developed an accurate isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method for serum C-peptide measurement and explored its use in harmonization.
Methods: After protein precipitation with ZSO solution, C-peptide was extracted from serum samples by anion-exchange solid-phase extraction and quantified by ID-LC-MS/MS in positive ion mode.
Background: Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools' commutability between insulin immunoassays, and their short- and long-term stability at different temperatures. The agreement between commonly used immunoassays was also evaluated.
View Article and Find Full Text PDFObjectives: The aim of the current study was to establish a reliable candidate reference method for serum 25-hydroxyvitamin D [25(OH)D] measurement and to assess the commutability of multiple control materials among liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods.
Methods: Serum 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] together with spiked internal standards were extracted with a one-step approach and then analyzed by LC-MS/MS. The commutability assessment for 25(OH)D was conducted according to the Clinical and Laboratory Standards Institute (CLSI) EP14-A3 protocol.
Organic acid (OA) analysis is a specific test for inherited metabolic disorders (IMDs); however, the previous detection methods are laborious and costly. This study aims to develop a rapid method for the simultaneous quantification of serum and urine OA profiles. The method was established based on the liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique.
View Article and Find Full Text PDFImmunopharmacol Immunotoxicol
April 2023
Background: Resistance to chemotherapeutic drugs limits the control of gastric cancer (GC) development. The study intended to probe into the mechanism of aquaporin 3 (AQP3) on the chemoresistance of GC.
Methods: Cisplatin CDDP)-resistant cells were constructed.
Objectives: A trueness-based EQA/PT program for high density lipoprotein cholesterol (HDL-C) was initiated. We analyzed the 4 year EQA/PT program to overview the measurement standardization for HDL-C in China.
Methods: Two levels of freshly frozen, commutable serum external quality assessment/proficiency testing (EQA/PT) materials were prepared and determined by reference measurement procedure each year.
Background: To identify candidate external quality assessment (EQA) materials for normetanephrine and metanephrine measurements, we assessed the commutability of eight processed human plasma samples. The agreement between routine assays and the candidate reference measurement procedure (cRMP) was also evaluated.
Methods: Fifty-three clinical samples and eight processed plasma samples were prepared.
BACKGROUND The purpose of this study was to determine the safety and efficacy of enteral nutrition in combination with microbial preparations for bowel preparation in elderly patients with colorectal cancer. MATERIAL AND METHODS Were divided 160 patients diagnosed with colorectal cancer into a control group (n=80) and an experimental group (n=80) by random number table method. The control group took the traditional intestinal preparation, and the experimental group took oral enteral nutrition combined with microbial preparations.
View Article and Find Full Text PDFOur study mainly reports the specific mechanisms of microRNA (miR)-874-3p on drug resistance in gastric cancer (GC). Clinical specimen was collected. The upstream long non-coding RNA (lncRNA) and the downstream gene of miR-874-3p were predicted using bioinformatic analysis with the results being ascertained with dual-luciferase reporter assay.
View Article and Find Full Text PDFBackground: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories.
Methods: Patient serum samples were pooled into five groups according to insulin and C-peptide concentrations and measured in 94 laboratories using different measurement systems.
To evaluate the consistency of six mainstream homogeneous systems for aminotransferase measurements and improve the consistency of measurements by applying uniform calibrators. 200 individual samples were grouped into four sets for assays with and without pyridoxal-5-phosphate (P-5'-P) for Alanine aminotransferase (ALT) and aspartate aminotransferase (AST). Routine assays for the P-5'-P group were compared with a reference measurement procedure (RMP).
View Article and Find Full Text PDFHuman C-peptide is secreted in equimolar amounts with insulin by pancreatic beta-cells. Measurement of C-peptide plays an important role in the diagnosis and treatment of diabetes where it is used to evaluate the function of islet cells. However, C-peptide measurement results across different laboratories vary considerably and there is an urgent need to improve comparability between laboratories.
View Article and Find Full Text PDF