Publications by authors named "H Rios"

Background And Objective: Sickle cell disease (SCD) is a vascular disease that may affect the retina. This study aimed to evaluate differences in average velocity (AV, mm/s), blood flow (BF, μL/min) and vessel diameter (VD, μm) from the temporal retinal arcades in SCD compared to healthy eyes using Doppler optical coherence tomography (DOCT).

Patients And Methods: A cross-sectional study was conducted between 2021 and 2023.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate how different artificial tears (AT) affect the thickness of tear film sublayers using a new imaging device.
  • Results showed that all tested ATs significantly increased the mucoaqueous layer thickness (MALT) at 1 minute post-instillation, with the Systane Complete PF (SYS) formulation providing the most substantial increase.
  • The findings suggest that while all ATs work quickly to enhance tear film thickness, the effectiveness and duration of these effects vary, indicating the need for personalized AT selection for patients.
View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the effects of artificial tears (AT) on the sublayers of the tear film assessed by a novel tear film imaging (TFI) device.

Methods: The mucoaqueous layer thickness (MALT) and lipid layer thickness (LLT) of 198 images from 11 healthy participants, 9 of whom had meibomian gland disease, were prospectively measured before and after exposure to 3 different AT preparations (Refresh Plus; Retaine [RTA]; Systane Complete PF [SYS]), using a novel nanometer resolution TFI device (AdOM, Israel). Participants were assessed at baseline and at 1, 5, 10, 30, and 60 minutes after instilling 1 drop of AT during 3 sessions on separate days.

View Article and Find Full Text PDF

The conformational changes of poly(maleic anhydride--styrene) (PSMA) modified with different amino acids (PSMA-Aa) were studied in an aqueous medium as a function of ionic strength and pH. The specific viscosity of PSMA-Aa decreased with increasing salt concentration due to a more compact conformation. There was a decrease in surface tension with increasing concentrations of the modified polyelectrolyte having a greater effect for the PSMA modified with l-phenylalanine at pH 7.

View Article and Find Full Text PDF

This manuscript deals with the trajectory-tracking problem for linear time-invariant systems with parameter uncertainties and time-dependent external perturbations. A robust finite-time model reference adaptive controller is proposed. In the absence of external perturbations, the proposed controller ensures finite-time convergence to zero of the tracking and parameter identification errors.

View Article and Find Full Text PDF