Objectives: To assess outcomes for patients undergoing transcatheter aortic valve implantation (TAVI) versus surgical aortic valve replacement but with less than high risk.
Background: While there is abundant data for high risk patients there is insufficient data for reduced risk.
Methods: Patients undergoing TAVI or SAVR between 2007 and 2012 in Karlsruhe were considered.
Background: Transapical transcatheter aortic valve implantation is generally perceived to be associated with increased morbidity compared with transfemoral transcatheter aortic valve implantation. We aimed to compare access-related complications and survival using propensity score matching.
Methods And Results: Prospective, single-center registry of 1000 consecutive patients undergoing transapical and transfemoral transcatheter aortic valve implantation between May 2008 and April 2012.
Background: Compared with surgical aortic valve replacement, transcatheter aortic valve implantation (TAVI) is associated with a higher risk of developing a new conduction disorder that necessitates permanent pacemaker implantation (PM). The most frequently observed conduction disorder is left bundle branch block (LBBB), which impairs left ventricular function.
Objectives: The primary objective of this study was to assess the incidence and prognostic significance of persistent new-onset LBBB following TAVI.
Background: Aortic rupture of the device landing zone is a rare complication of transcatheter aortic valve implantation (TAVI) and it is associated with significant mortality.
Methods: This study reports on the experience of a single-center in a case series of more than 1,000 implants. We explored patient and procedural characteristics aiming at identifying variables that increase the risk for aortic root rupture.
Background: This prospective study examines the impact of EuroSCORE and transfemoral (TF) or transapical (TA) delivery approach on mortality at 30 days and 1 year in patients with severe aortic stenosis implanted with either the Edwards SAPIEN Transcatheter Heart Valve (THV) or Medtronic CoreValve.
Methods And Results: TAVI was successfully performed in 293 (97.7%) of 300 patients (TF: 174, TA: 126, mean EuroSCORE 24.