Publications by authors named "H Mathisen"

A prevailing belief among researchers is that burnout is a work-specific syndrome induced by intractable job stress. The validity of this belief, however, remains unclear. This cross-sectional study compared burnout with two general conditions, nonspecific psychological distress (NSPD) and exhaustion, in terms of (a) causal attributions to work and (b) associations with 11 job variables (e.

View Article and Find Full Text PDF

In this study, concentrations of pollutants: formaldehyde, carbon dioxide (CO), and total volatile organic compounds (TVOC) and parameters: indoor room temperature and relative humidity (RH) were measured in 21 home offices for at least one week in winter in Trondheim, Norway. Eleven of these were measured again for the same duration in summer. Potentially explanatory variables of these parameters were collected, including building and renovation year, house type, building location, trickle vent status, occupancy, wood stove, floor material, pets, RH, and air temperature.

View Article and Find Full Text PDF

The purpose of this study was to reveal the exposure level of surgical staff to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from the patient's nose and wound during operations on COVID-19 patients. The tracer gas NO is used to simulate SARS-CoV-2 from the patient's nose and wound. In this study, concentration levels of tracer gas were measured in the breathing zones of these surgical staff in the operating room under three pressure difference conditions: -5 pa-15 pa and -25 pa compared to the adjunction room.

View Article and Find Full Text PDF

Fiber Bragg gratings inscribed in single crystalline multimode sapphire fibers (S-FBG) are suitable for monitoring applications in harsh environments up to 1900 °C. Despite many approaches to optimize the S-FBG sensor, a metrological investigation of the achievable temperature uncertainties is still missing. In this paper, we developed a hybrid optical temperature sensor using S-FBG and thermal radiation signals.

View Article and Find Full Text PDF

Objectives: The level of airborne microbial contamination in operating rooms (ORs) is an important indicator of indoor air quality and ensures a clean surgical environment. The main objective of this study was to clarify the possibility of achieving the requirement for an ultraclean operating room (≤ 10 CFU/m) with mixed flow ventilation based on clothing and human activity.

Methods: Experimental measurements during mock surgeries were conducted in an actual OR with mixed flow ventilation in the Emergency, Heart and Lung Centre at St.

View Article and Find Full Text PDF