Background: We investigated the pathogenic, clinical, and laboratory characteristics of children diagnosed with septic arthritis (SA) during the past 24 years and identified the risk factors for SA-related sequelae.
Methods: We retrospectively reviewed the records of patients admitted to Fukuoka University Hospital from 1997 to 2020. Causative pathogens were compared between the first (1997-2008) and second (2009-2020) periods.
Background: Invasive candidiasis (IC) is a leading cause of morbidity and mortality in preterm infants. The objective of this study was to determine the prevalence of IC infection in newborns in the neonatal intensive care unit (NICU) of a tertiary hospital in Japan, and to identify specific predisposing factors for IC.
Methods: We retrospectively collected data on demographics, clinical characteristics, and outcomes of infants with IC, who were discharged from a tertiary NICU in Japan between January 2009 and December 2020.
To examine acute effects of olprinone hydrochloride (CAS 106730-54-0, Coretec) on pulmonary hypertension, hypoxic pulmonary hypertension was produced in 6 adult Beagle dogs. Using this pulmonary hypertension model, single intravenous bolus injections of olprinone at doses of 10, 30 and 100 micrograms/kg were administered at 5-min intervals and hemodynamic parameters were evaluated. Heart rate increased at doses of 30 and 100 micrograms/kg, but did not change at a dose of 10 micrograms/kg.
View Article and Find Full Text PDFPacing Clin Electrophysiol
April 1999
His-bundle pacing gives a more physiological ventricular contraction in comparison to right ventricular apical pacing. However the problems of lead fixation and stability of long-term His-bundle pacing are yet unsolved. We used six adult beagles, in which a screw-in lead was anchored in the His-bundle region for observation of the pacing conditions and histopathologic changes of the conduction system over the course of 2 months.
View Article and Find Full Text PDFA pacemaker was implanted into a 17-year-old man with cardiac failure due to complete atrioventricular block complicated by mitochondrial encephalomyopathy (Kearns-Sayre syndrome). Due to the possible complication of latent myocardial dysfunction, it was decided to implant the dual chamber pacemaker (DDD) and the operation mode was set to DDD 70 ppm 1 year after implantation; this alleviated the cardiac failure. In this case, the necessity of preventive pacemaker implantation in the early stage of cardiac failure was recognized.
View Article and Find Full Text PDF