Publications by authors named "H Ishitobi"

High-speed atomic force microscopy (HS-AFM) is an indispensable technique in the field of biology owing to its imaging capability with high spatiotemporal resolution. Furthermore, recent developments established tip-scan stand-alone HS-AFM combined with an optical microscope, drastically improving its versatility. It has considerable potential to contribute to not only biology but also various research fields.

View Article and Find Full Text PDF

Background: Animal models of spontaneous osteoarthritis (OA) are sparse and not well characterized. The purpose of the present study is to examine OA-related changes and mechanisms in senescence-accelerated mouse prone 8 (SAMP8) that displays a phenotype of accelerated aging.  METHODS: Knees of male SAMP8 and SAM-resistant 1 (SAMR1) mice as control from 6 to 33 weeks of age were evaluated by histological grading systems for joint tissues (cartilage, meniscus, synovium, and subchondral bone), and µCT analysis.

View Article and Find Full Text PDF

The transmission of neuronal information is propagated through synapses by neurotransmitters released from presynapses to postsynapses. Neurotransmitters released from the presynaptic vesicles activate receptors on the postsynaptic membrane. Glutamate acts as a major excitatory neurotransmitter for synaptic vesicles in the central nervous system.

View Article and Find Full Text PDF

Background/aims: Unsedated transnasal esophagogastroduodenoscopy (EGD) is affected by a poor scope lens-cleaning function. We have previously reported good, albeit limited, effects of an oolong tea washing solution; here, we evaluated the effectiveness of a 5% lens cleaning solution for cleaning an EGD lens.

Methods: Five percent lens cleaning solution (C), 5% dimethicone solution (D), and distilled water (W) were prepared.

View Article and Find Full Text PDF

Objectives: The aim was to clarify the sensitivity and specificity of diffusion-weighted imaging, as well as of that in combination with magnetic resonance cholangiopancreatography for pancreatic tumor diagnosis in real-world clinical setting.

Methods: Subjects were 217 consecutive patients who underwent both magnetic resonance imaging and contrast-enhanced ultrasound sonography. Cases positive for a pancreatic tumor were confirmed based on pathological diagnosis, whereas negative cases were defined when no solid pancreatic tumor was detected by contrast-enhanced ultrasound sonography or a solid mass was detected but the diagnosis was ultimately denied based on pathological results.

View Article and Find Full Text PDF