We describe our development of a CH4 preconcentration system for use with continuous-flow gas chromatograph combustion isotope ratio mass spectrometry (GC/C/IRMS). Precision of measurement of delta13C-CH4 is 0.05/1000 (1sigma) on multiple 60-mL aliquots of the same ambient air sample.
View Article and Find Full Text PDFBackground: The [13C]urea breath test for Helicobacter pylori is nonradioactive, as well as noninvasive, but few clinical laboratories have the expensive isotope ratio mass spectrometer used for analysis.
Methods: To demonstrate the feasibility of analysing [13C]urea breath tests with a gas chromatograph-mass spectrometer routinely used for drug testing, 13CO2 standards for breath tests and breath samples from patients in a multiple-blind study were analysed. The breath samples were also analysed by isotope ratio mass spectrometry, and the diagnoses were compared with biopsy results.
Objectives: American female adolescents are at high risk of a physically inactive lifestyle that likely leads to health problems later in life. We hypothesized that a brief program of endurance exercise training in female adolescents would result in increased energy expenditure and quantifiable structural and functional adaptations.
Study Design: Forty-four high school girls (aged 15 to 17 years, none were elite athletes) enrolled in a 5-day per week anatomy class for 5 weeks and were randomly assigned to control (n = 22) and training groups.
To determine the contributions of preexisting fatty acid, de novo synthesis, and chain elongation in long-chain fatty acid (LCFA) synthesis, the synthesis of LCFAs, palmitate (16:0), stearate (18:0), arachidate (20:0), behenate (22:0), and lignocerate (24:0), in the epidermis, liver, and spinal cord was determined using deuterated water and mass isotopomer distribution analysis in hairless mice and Sprague-Dawley rats. Animals were given 4% deuterated water for 5 days or 8 wk in their drinking water. Blood was withdrawn at the end of these times for the determination of deuterium enrichment, and the animals were killed to isolate the various tissues for lipid extraction for the determination of the mass isotopomer distributions.
View Article and Find Full Text PDFRecent developments in the application of stable isotopes and mass spectrometry have permitted the estimation of precursor enrichment and fractional synthesis of the product through mass isotopomer analysis. Thus, the application of isotopomer analysis in studies with 2H- and 13C-labeled glucose may potentially overcome the limitations of traditional methods which can only estimate the fractional use of carbon and hydrogen from glucose for lipogenesis. To illustrate this approach, isotope incorporation and mass isotopomer distribution were determined in fatty acids and cholesterol from a hepatoma cell line (Hep G2) grown in media containing specific (C1 or C6) 2H- or 13C-labeled glucose.
View Article and Find Full Text PDF