Introduction: The aim of this study was to experimentally measure organ doses for computed tomography (CT) procedures using thermoluminescence dosimeters (TLDs) on a RANDO anthropomorphic phantom and verify the measured doses using CT-Expo software.
Methods: The phantom was irradiated using clinical CT scan protocols routinely used for specific procedures in the radiology department. Fifty TLD chips were used in this study.
Dose and secondary cancer risk of the breast and thyroid during high dose rate (HDR) brachytherapy for 100 gynaecological cancer patients have been estimated. The organ doses were measured using LiF thermoluminescence dosimeters LiF (TLD-100). Patient demographic data (i.
View Article and Find Full Text PDFIntroduction: to address the challenge of inadequate and non-equitable distribution of diagnostic imaging equipment, countries are encouraged to evaluate the distribution of installed systems and undertake adequate monitoring to ensure equitability. Ghana´s medical imaging resources have been analyzed in this study and evaluated against the status in other countries.
Methods: data on registered medical imaging equipment were retrieved from the database of the Nuclear Regulatory Authority and analyzed.
Preliminary studies on effective and eye lens doses of six Radiologists, four Cardiologists have been conducted for a period of 3 months. Electronic dosemeters positioned under and over lead apron of staff were used for the dosimetry. The estimated effective dose per month to Cardiologist and Radiologist were 0.
View Article and Find Full Text PDFRadiat Prot Dosimetry
September 2016
Studies have shown that there is high radiation exposure to medical staff during computed tomography fluoroscopy (CTF)-guided procedures. This study aims to investigate staff dose reduction techniques considering the CTF gantry positioning in the room and room dimensions in addition to the conventional use of thyroid collars, aprons and eye goggles. A Toshiba Aquilion One 640 slice CT scanner and CTF room were modelled using SimpleGeo.
View Article and Find Full Text PDFRadiation dose to organs of 100 adult patients undergoing lumbar spine (LS) radiography at a University Hospital have been assessed. Free in air kerma measurement using an ionization chamber was used for the patient dosimetry. Organ and effective dose to the patients were estimated using PCXMC (version 1.
View Article and Find Full Text PDFThe log file generated in the flat panel detector of a direct digital x-ray machine (General Electric, Haulun Medical Systems, Serial Number 8M0392) after x-ray exposure was used to acquire data regarding the entrance surface air kerma (ESAK) for some routine x-ray examinations. The data were collected for a minimum of 10 standard adult patients undergoing each examination considered. The mean ESAK were found to be 0.
View Article and Find Full Text PDFCancer incidence estimates and dosimetry of 120 patients undergoing hysterosalpingography (HSG) without screening at five rural hospitals and with screening using image intensifier-TV at an urban hospital have been studied. Free in air kerma measurements were taken for patient dosimetry. Using PCXMC version 1.
View Article and Find Full Text PDFThe status of radiation protection and safety of diagnostic medical x-ray facilities in the Greater Accra region in Ghana have been evaluated. In all, 62 medical facilities with 86 diagnostic x-ray units were considered for the survey. Out of the 86 diagnostic units, there were 56 general radiograph, 13 dental radiography, 9 fluoroscopy, 5 computed tomography, and 3 mammography machines.
View Article and Find Full Text PDFThe International Basic Safety Standards requires that all personnel on whom protection and safety depends be trained and qualified. The Radiation Protection Institute of the Ghana Atomic Energy Commission has adopted a systematic approach to training those occupationally exposed to ionizing radiation in the course of their work. In collaboration with the International Atomic Energy Agency several training courses have been implemented at the national level and in the African region.
View Article and Find Full Text PDFA (60)Co radiotherapy source with an initial activity of 185 TBq has exhausted its useful half-life and has been replaced with a 222 TBq (60)Co source at the Korle-Bu Teaching Hospital; a radiological assessment was performed to ascertain the shielding integrity of the facility. Dose rate at selected critical positions were calculated for the old and new sources. Dose rate measurements were also performed at these critical locations for the new source.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2010
The safety culture of selected practices and facilities in Ghana utilising radiation sources or radiation emitting devices has been assessed using a performance indicator, which provided status information on management and operating staff commitment to safety. The questionnaire was based on the following broad areas: general safety considerations, safety policy at the facility level, safety practices at the facility level, definition of responsibility, staff training, safety of the physical structure of the facility and the emergency plans. The analysis showed that the percentage levels of commitment to safety for the respective practices are as follows: conventional radiography, 23.
View Article and Find Full Text PDFRadiat Prot Dosimetry
September 2009
Organ and effective doses to 90 patients undergoing some selected fluoroscopic examinations at the Korle-Bu Teaching Hospital were estimated using the Monte Carlo-based program (PCXMC version 1.5). Radiation dose was estimated from free-in-air measurements.
View Article and Find Full Text PDF