Objective: Evaluation of the accuracy of direct digitization of maxillary scans depending on the scanning strategy.
Materials And Methods: A maxillary model with a metal bar as a reference structure fixed between the second molars was digitized using the CEREC Primescan AC scanner (N = 225 scans). Nine scanning strategies were selected (n = 25 scans per strategy), differing in scan area segmentation (F = full jaw, H = half jaw, S = sextant) and scan movement pattern (L = linear, Z = zig-zag, C = combined).
Objectives: To assess the clinical performance of tooth-supported 3-unit fixed dental prostheses (FDPs) made from shade-graded monolithic 5Y-PSZ (partly stabilized zirconia) zirconia in terms of survival rate and the quality of restorations based on modified FDI criteria over three-years.
Materials And Methods: High-translucent shade-graded monolithic zirconia (Lava Esthetic, Solventum Dental Solutions) was used to manufacture maxillary or mandibular three-unit FDPs in the posterior region (N = 22) employing subtractive milling system (Amann Girrbach). All FDPs were bonded with a universal resin cement (Rely X Universal, Solventum Dental Solutions) and evaluated 4 weeks after cementation (baseline) and after 1, 2, and 3 years.
Purpose: Customized healing abutments are utilized to enhance aesthetics and peri-implant soft and hard tissue health, and play a crucial role in the implant-prosthetic workflow. This systematic review was performed to assess and compare the clinical outcomes of customized healing abutments with conventional ones.
Methods: The review was registered with PROSPERO (ID: CRD42024532449) and followed the PRISMA-guidelines.
Clin Implant Dent Relat Res
October 2024
Background: The determination of the maxillary occlusal plane presents a significant clinical challenge in the treatment of edentulous patients as well as it is critical for complex full-mouth reconstructions in dentate patients, including those with implant-supported rehabilitations. While the use of a Fox plane plate is standard in edentulous cases, its application in dentate patients lacks thorough documentation in existing literature.
Purpose: This clinical study assessed the sagittal position of the maxillary dentition in relation to facial landmarks using a digital three-dimensional analysis and evaluated the suitability and reliability of applying a simulated Fox plane plate, also known as an occlusal plane guide, in dentate patients.
Objectives: Clinical data on all-ceramic screw-retained implant crowns (SICs) luted on titanium base abutments (TBAs) over more than 3 years are sparse. This study aimed to evaluate the clinical performance and potential risk factors for these restorations.
Materials And Methods: Analysis took place based on the medical patient-records of three dental offices.
The nuclear receptors hepatocyte nuclear factor 4α (HNF4α) and retinoic acid receptor-related orphan receptor-β (RORβ) are ligand-regulated transcription factors and potential drug targets for metabolic disorders. However, there is a lack of small molecular, selective ligands to explore the therapeutic potential in further detail. Here, we report the discovery of greater celandine (Chelidonium majus) isoquinoline alkaloids as nuclear receptor modulators: Berberine is a selective RORβ inverse agonist and modulated target genes involved in the circadian clock, photoreceptor cell development, and neuronal function.
View Article and Find Full Text PDFPurpose: This in vitro study investigated the influence of material selection, crown morphology, and vertical crown height on the biomechanical behavior of screw-retained monolithic hybrid abutment crowns (HACs).
Methods: Ninety implants were embedded in accordance with ISO standard 14801; ninety HACs were mounted (N=90). Monolithic crowns with varying group-specific designs were luted using titanium bases.
Objectives: Different approaches to prosthodontic consultation, all involving a strong focus on shared decision-making, were analyzed from the perspective of patients by inter-group comparisons. No patient decision aid (PDA) was used in the control group, a paper-based PDA in test group 1, and a software-based PDA in test group 2.
Materials And Methods: Seventy-five patients were prospectively randomized to the control group or a test group.
Purpose: To evaluate the behavior of hybrid abutment crowns fabricated from monolithic lithium disilicate ceramic (LDC) and to compare the influence of different in vitro artificial aging protocols.
Materials And Methods: A total of 32 monolithic hybrid abutment crowns of monolithic LDC were fabricated. Of these, 24 were artificially aged using three different protocols up to a 20 year simulation (1.
Objectives: Bone resorption around implants could influence the resistance of the implant abutment complex (IAC). The present in vitro study aimed to assess the stability to static fatigue of implants presenting different levels of bone losses and diameters.
Materials And Methods: Ninety implants with an internal conical connection with 3 different implant diameters (3.
Purpose: Hybrid abutment crowns (HACs) made from monolithic ceramics represent an efficient option for single restorations on implants. However, long-term data are scarce. The purpose of this clinical trial was to evaluate the survival and complication rates of CAD-CAM fabricated HACs over a time period of at least 3.
View Article and Find Full Text PDFBackground: Airway management with supraglottic airway devices (SGA) in life-threatening emergencies in children is increasingly being used. Different specifications of laryngeal masks (LM) and the laryngeal tube (LT) are commonly used devices for this purpose. We present a literature review and interdisciplinary consensus statement of different societies on the use of SGA in pediatric emergency medicine.
View Article and Find Full Text PDFObjective: Several extrusion techniques have been described to restore teeth with insufficient coronal tooth structure and to avoid their extraction. Still, there is little evidence for a treatment concept combining surgical extrusion using an atraumatic axial extraction system.
Materials And Methods: A total of nine patients, each with an iso- or subgingival fractured tooth, were retrospectively examined.
Pronounced defects of the dental hard tissue can be caused by different etiologic factors. Most frequently, they are associated with changes in the vertical dimension of occlusion (VDO), which may also influence the condylar positions. These defects can lead to irreversible loss of tooth structure and have dramatic functional and esthetic consequences, often requiring complex rehabilitation.
View Article and Find Full Text PDFThe thickness of a material has a significant impact on its fracture load. The aim of the study was to find and describe a mathematical relationship between the material thickness and the fracture load for dental all-ceramics. In total, 180 specimens were prepared from a leucite silicate ceramic (ESS), a lithium disilicate ceramic (EMX), and a 3Y-TZP zirconia ceramic (LP) in five thicknesses (0.
View Article and Find Full Text PDF(1) Background: New intraoral (IOS) and laboratory scanners appear in the market and their trueness and precision have not been compared. (2) Methods: Seven IOS and two laboratory scanners were used to scan a mandibular edentulous model with four parallel internal hexagon implant analogues and PEEK scan bodies. Digital models in Standard Tessellation Language (STL) were created.
View Article and Find Full Text PDFAim: The CAM of esthetically pleasing monolithic dental restorations presents with specific challenges. One vital parameter to consider is the translucency of the materials. Previous studies have proven a correlation between translucency and material thickness for various all-ceramic materials.
View Article and Find Full Text PDFBackground: Digital teaching and learning tools, such as computer/mobile apps, are becoming an important factor in modern university education. The objective of our study was to introduce, analyze, and assess an organization and dual assessment app for clinical courses in dental medicine.
Methods: This was a survey-based study of dental students from the clinical study phase (4th/5th year; 8th/10th semester) of a department of prosthetic dentistry at a German university hospital about the benefits of a novel web-based and mobile app for organization and dual assessment of dental clinical courses.
Purpose This in vitro study aimed to investigate the long-term performance, stability, and fracture mode of monolithic hybrid abutment crowns, and the effect of different materials on the implant-abutment interface (IAI).Methods Eighty monolithic hybrid abutment crowns luted on titanium bases were manufactured from 3Y-TZP zirconia (ZY3), "Gradient Technology" zirconia (ZY35), 5Y-TZP zirconia (ZY5), lithium disilicate ceramic (LDS), zirconia-reinforced lithium silicate ceramic (ZLS), polymer-infiltrated ceramic network (MHY), polymethylmethacrylate (PMA), and 3D-printed hybrid composite (PHC) (n = 10 for each material). Eighty implants (Camlog Progressive-Line, diameter: 3.
View Article and Find Full Text PDFPurpose: To perform a systematic review of posterior tibial stress radiography techniques and radiographic measurement methods to compare their accuracy and efficacy to aid clinicians in quantifying posterior cruciate ligament laxity.
Methods: Electronic databases, including PubMed, MEDLINE, Embase.com 1947- , Ovid Medline 1946- , Scopus 1823- , Cochrane Central Register of Controlled Trials (CENTRAL), and Clinicaltrials.
Purpose: To analyze the clinical performance of two-wing–retained resin-bonded fixed dental prostheses (RBFDPs) after 5 years of clinical use with respect to technical and biologic complications, as well as survival and success rates.
Materials And Methods: RBFDPs were fabricated from 3Y-TZP zirconia layered by hand (Lava Frame veneered with Lava Ceram; 3M ESPE) or metal (Remanium Star, Dentaurum; layered with Reflex, Wieland). The primary endpoints were debonding and fracture.
The aim of this in vitro study is to investigate the bonding properties of a 3D-printable permanent composite material in comparison to milled composite materials. The tested materials are 3D-printed BEGO VarseoSmile Crown plus (VA1_ab, VA1_nt, VA2_ab, VA2_nt), Vita Enamic (EN1, EN2), and 3M Lava Ultimate (UL1, UL2) (N = 64; n = 8). For this purpose, all crowns are luted to polymer tooth stumps #46 (FDI) using dual-curing luting composite, strictly according to the manufacturer’s instructions.
View Article and Find Full Text PDFPurpose: To evaluate the shear bond strength (SBS) of different digital veneering techniques for zirconia and to critically discuss its suitability for application in single-implant prosthetics.
Materials And Methods: A total of 112 square-shaped zirconia specimens were provided with four different veneering materials (n = 28 per group): a glass-ceramic (group GLA), a feldspathic ceramic (group FEL), a polymer-infiltrated ceramic network (group PIC), and a resin nanoceramic (group RNC). Discs in group GLA were sintered onto the core material, whereas all other specimens were adhesively connected.
Water quality surveillance can help to reduce waterborne diseases. Despite better access to safe drinking water in Sierra Leone, about a third of the population (3 million people) drink water from unimproved sources. In this cross-sectional study, we collected water samples from 15 standpipes and 5 wells and measured the physicochemical and bacteriological water quality, and the antimicrobial sensitivity of Escherichia coli (E.
View Article and Find Full Text PDFImplementing and monitoring infection prevention and control (IPC) measures at immigration points of entry (PoEs) is key to preventing infections, reducing excessive use of antimicrobials, and tackling antimicrobial resistance (AMR). Sierra Leone has been implementing IPC measures at four PoEs (Queen Elizabeth II Quay port, Lungi International Airport, and the Jendema and Gbalamuya ground crossings) since the last Ebola outbreak in 2014-2015. We adapted the World Health Organization IPC Assessment Framework tool to assess these measures and identify any gaps in their components at each PoE through a cross-sectional study in May 2021.
View Article and Find Full Text PDF