This study aimed to evaluate the scanning time and marginal fit of CAD/CAM crowns fabricated using different intraoral scanning systems (IOS) (O1-Omnicam 1.0, O2-Omnicam 2.0, PS-Primescan).
View Article and Find Full Text PDFThis research analyzed the effect of the manufacturing method on the flexural strength and color stability of 3D-printed resins used for producing indirect restorations. For this, two dental restorative biocompatible resin materials, OnX (OnX, SprintRay) and CB (Crown and Bridge, Dentca), were divided into 2 groups according with manufacturing method (printed with a Pro95 3D printer - SprintRay; and not printed, with samples obtained with the fluid resin being poured on PVS molds for further light activation in the post-curing process), and subdivided into 2 groups according to the post-curing method: VG (Valo Grand, Ultradent Products) for 120 s and PC (Procure 2, SprintRay). Bar-shaped samples were used to evaluate the flexural strength 24 h after storage in distilled water at 37 °C using a universal testing machine.
View Article and Find Full Text PDFComputer-aided manufacturing (CAM) technology allows the use of different manufacturing techniques. This in vitro study aimed to evaluate the marginal fit of temporary restorations manufactured using conventional chairside methods, milling, and three-dimensional printing. Fifteen 3-element temporary restorations specimens were produced and categorized into three groups: non-digital, obtained using the conventional chairside method (GC); milled (GM); and three-dimensionally printed (GP).
View Article and Find Full Text PDFOsong Public Health Res Perspect
June 2024
Background: The objective of this study was to examine the hypothesis that periodontal disease is associated with chronic non-communicable diseases.
Methods: In this cross-sectional study, we evaluated the periodontal health condition of the population, based on the community periodontal index, as well as the number of missing teeth and the presence of systemic health conditions. We quantified the association between oral health and the presence of chronic diseases using simple logistic regression, adjusting for confounding factors including age, smoking, and overweight.
Objectives: Ultrasound (US) reveals details for diagnosing soft- and hard-tissue dimensions around teeth, implants, and the edentulous ridge, not seen in 2D radiographs. Co-registering free-hand US scans with other 3D modalities presents reliability challenges. This study first aims to develop and validate a registration method to longitudinally reproduce US images of the jawbone on a simulator.
View Article and Find Full Text PDFObjectives: The objective of this study is (1) to compare the accuracy of an open-sleeved static computer-assisted implant system (sCAIS) with a closed-sleeve sCAIS and free-hand approach in immediate implant placement (IIP) of maxillary molar sites and (2) to investigate the influence of socket morphology on these approaches.
Materials And Methods: Ninety partially edentulous duplicated maxillary models simulating three different molar sockets (type A, B, and C based on Smith and Tarnow's classification) were investigated. Three modalities, including sCAIS with open-sleeves, sCAIS with closed-sleeves, and free-hand approach, were applied separately to 30 models with 120 sockets.
The goal of this clinical report was to present an alternative to traditional flat bone reduction guides, using a custom-designed 3-dimensional (3D)-printed guide according to the future gingival margin of the planned dentition. A 61-year-old woman with concerns regarding her smile appearance was presented. The initial examination revealed excessive gingival show accompanied by excessive overjet.
View Article and Find Full Text PDFPurpose: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers.
Materials And Methods: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner.
This study aimed to compare the accuracy of full-arch digital implant impressions using seven different scanbodies and four intraoral scanners. A 3D-printed maxillary model with six implants and their respective multi-unit abutments was used for this study. Seven scanbodies (SB1, SB2, SB3, SB4, SB5, SB6, and SB7) and four intraoral scanners (Primescan®, Omnican®, Trios 3®, and Trios 4®) were assessed.
View Article and Find Full Text PDFA sinus floor elevation via lateral window (LSFE) is one of the most widely used bone augmentation procedures for implant therapy in the posterior area of the maxilla. Locating and preparing a correct opening window on the lateral sinus wall is a key step of this procedure. Conventionally, the surgeon designs and locates the window after the flap is reflected based on the information obtained from cone-beam computed tomography (CBCT) images or other diagnostic aids.
View Article and Find Full Text PDFPerforming soft tissue augmentation (STA) at implant sites to improve esthetics, patient satisfaction, and peri-implant health is common. Several soft tissue grafting materials can be used to increase soft tissue thickness at the second-stage surgery, including human dermal matrices and xenogeneic collagen scaffolds. This study assessed and compared the volumetric outcomes, from second-stage surgery to crown delivery, around implants that received STA with a xenogeneic cross-linked collagen scaffold (XCCS) vs nonaugmented implant sites.
View Article and Find Full Text PDFBackground: The objective was to compare physic-mechanical properties of different materials used for temporary restorations.
Material And Methods: Protemp 4/bisacrylic resin, Jet/acrylic resin, and Nexdent C&B/3D-printed resin samples (10mm diameter x 2mm thickness) were analyzed for surface roughness and color stability tests (baseline, after 5 thousand brushing cycles; and after artificial aging in water at 60oC for 24 hours) and Knoop microhardness. All data were checked for normality using Shapiro-Wilk test.
Objectives: This in vitro comparative study aimed to evaluate the physical and mechanical properties of four 3D-printed resins with two different thickness layers.
Methods: Four printed resins (VarseoSmile Crown Plus, VSC; NexDent C&B MFH, MFH; Nanolab 3D, NNL; and Resilab 3D Temp, RSL) were printed with 50 µm and 100 µm layer thickness, resulting in 80 bars measuring 25 × 2×2 mm. The specimens underwent a Raman spectroscopy for degree of conversion, confocal laser scanning microscopy for surface roughness (Sa), three-point bending test for flexural strength and elastic modulus, and a Vickers hardness test (VHN).
Objectives: To evaluate the efficacy of various interdental cleaning aids for artificial biofilm removal on different implant-supported crown designs.
Methods: Mandibular models with missing first molar were fabricated and installed with single implant analogs and loaded with crowns of different designs (concave, straight, and convex). Artificial biofilm was made with occlusion spray.
Purpose: To investigate the accuracy of a novel sleeveless implant surgical guide by comparing it with a conventional closed-sleeve guide and a freehand approach.
Materials And Methods: Custom resin maxillary casts with corticocancellous compartments were used (n = 30). Seven implant sites were present per maxillary cast, corresponding to healed (right and left first premolars, left second premolar and first molar) and extraction sites (right canine and central incisors).
Am J Orthod Dentofacial Orthop
May 2023
Introduction: Orthodontic treatment using clear aligners has experienced exponential growth since its introduction in the late 1990s. Three-dimensional (3D) printing has also grown in popularity among orthodontists, and companies have begun to produce resins to directly print clear aligners. This study aimed to examine the mechanical properties of commercially available thermoformed aligners and direct 3D-printed aligners under laboratory conditions and a simulated oral environment.
View Article and Find Full Text PDFInt J Oral Maxillofac Implants
April 2023
The objective of this in vitro study was to evaluate the activity of local gel containing metronidazole (MN) in the leakage area, which was analyzed by the DNA-DNA checkerboard hybridization method. Thirty-six sets of Morse taper/mini-pillar implants were used in this study. These implants were equally divided into the following three groups: MN gel (test group), no MN gel (negative test group), and no gel (control).
View Article and Find Full Text PDFThe two-implant-supported mandibular overdenture is considered a reliable treatment option to restore masticatory function. Digital planning has been shown to improve the precision and accuracy of the surgical procedure. The outcomes are indeed pertinent to the ideal three-dimentional positioning of the implant placement.
View Article and Find Full Text PDFStatement Of Problem: Optimal implant positioning is essential to achieving predictable results. Computer-guided surgery has been reported to be an accurate technique for implant placement in healed sites, but the accuracy of guided techniques for immediate implant placement into fresh sockets is still unclear.
Purpose: The purpose of this experimental randomized split-mouth study in pig jaws was to determine the accuracy of partially and fully guided surgical techniques for immediate implant placement into fresh sockets and to compare 2 different methods of implant position deviations analysis.
J Prosthet Dent
December 2024
Statement Of Problem: Monolithic ceramic implant-supported restorations have been used to rehabilitate partially edentulous patients. However, knowledge of the survival and prosthetic complications of single crowns (SCs) and fixed partial dentures (FPDs) is limited.
Purpose: The purpose of this systematic review with meta-analysis was to evaluate the clinical performance of monolithic ceramic implant-supported SCs and FPDs in terms of survival and prosthetic complication rates.
Statement Of Problem: Postpolymerization methods influence the properties of 3-dimensionally (3D) printed materials. Nevertheless, it is a time-consuming step that could lead dentists to avoid the chairside use of 3D printing. Information assessing the impact of different postpolymerization workflows on flexural strength and color stability is sparse.
View Article and Find Full Text PDFIn the digital dentistry era, new tools, algorithms, data science approaches, and computer applications are available to researchers and clinicians. However, there is also a strong need for better knowledge and understanding of multisource data applications, including three-dimensional imaging information such as cone-beam computed tomography images and digital dental models for multidisciplinary cases. In addition, artificial intelligence models and automated clinical decision systems are rising.
View Article and Find Full Text PDFObjective: The study aimed to assess the angular and linear deviations of implants installed in mannequins aided by surgical guides produced with the techniques of dual tomography (DT), model-based tomography (MT), and nonprototyped guide.
Materials And Methods: Implants were installed in mannequins of a partially edentulous maxilla and divided into three groups: Group C ( = 20), implants installed using the conventional technique with flap opening and conventional guide; Group DT ( = 20), implants installed using guided surgery with the dual tomography technique; and Group MT ( = 20), implants installed using the model-based tomography technique. After implant installation, the mannequin was subjected to a computed tomography (CT) to measure the linear and angular deviations of implant positioning relative to the initial planning on both sides.