Biology (Basel)
October 2020
Translational Boron Neutron Capture Therapy (BNCT) studies performed by our group and clinical BNCT studies worldwide have shown the therapeutic efficacy of BNCT for head and neck cancer. The present BNCT studies in veterinary patients with head and neck cancer were performed to optimize the therapeutic efficacy of BNCT, contribute towards exploring the role of BNCT in veterinary medicine, put in place technical aspects for an upcoming clinical trial of BNCT for head and neck cancer at the RA-6 Nuclear Reactor, and assess the feasibility of employing the existing B2 beam to treat large, deep-seated tumors. Five dogs with head and neck cancer with no other therapeutic option were treated with two applications of BNCT mediated by boronophenyl-alanine (BPA) separated by 3-5 weeks.
View Article and Find Full Text PDFThe analysis of the distribution and density of nuclear tracks forming an autoradiography in a nuclear track detector (NTD) allows the determination of B atoms concentration and location in tissue samples from Boron Neutron Capture Therapy (BNCT) protocols. This knowledge is of great importance for BNCT dosimetry and treatment planning. Tissue sections studied with this technique are obtained by cryosectioning frozen tissue specimens.
View Article and Find Full Text PDFThe aim of the present study was to evaluate, for the first time, the abscopal effect of boron neutron capture therapy (BNCT). Twenty-six BDIX rats were inoculated subcutaneously with 1 × 10 DHD/K12/TRb syngeneic colon cancer cells in the right hind flank. Three weeks post-inoculation, the right leg of 12 rats bearing the tumor nodule was treated with BPA-BNCT (BPA-Boronophenylalanine) at the RA-3 nuclear reactor located in Buenos Aires, Argentina, at an absorbed dose of 7.
View Article and Find Full Text PDFAim: to present the most important aspects of Microdosimetry, a research field in radiation biophysics.
Background: microdosimetry is the branch of radiation biophysics that systematically studies the spatial, temporal and spectral aspects of the stochastic nature of the energy deposition processes in microscopic structures.
Materials And Methods: we briefly review its history, the people, the formalism and the theories and devices that allowed researchers to begin to understand the true nature of radiation action on living matter.
Purpose: Patients with the same histopathologic diagnosis of cutaneous melanoma treated with identical protocols of boron neutron capture therapy (BNCT) have shown different clinical outcomes. The objective of the present studies was to evaluate the biodistribution of boronophenilalanina ((10)BPA) for the potential application of BNCT for the treatment of melanoma on an individual basis.
Methods And Materials: The boronophenilalanine (BPA) uptake was evaluated in 3 human melanoma cell lines: MEL-J, A375, and M8.
From 2008 to 2011, several planned modifications were implemented at the RA-6 reactor in Argentina, leading to significant benefits for future BNCT treatments. New capabilities have been implemented in NCTPlan treatment planning system. To assess the performance of the new BNCT facility, a dosimetric reevaluation of previous clinical cases was performed, taking into account the modifications carried out in the new facility and compared the results of the original treatment plans with optimized plans that are considered as feasible patient setups.
View Article and Find Full Text PDFWith the aim to relate the effects observed in a clinical boron neutron capture therapy protocol to the corresponding outcomes in a standard photon radiation therapy, "RBE-weighted" doses are customarily calculated by adding the contributions of the different radiations, each one weighted by a fixed (dose and dose rate independent) relative biological effectiveness factor. In this study, the use of fixed factors is shown to have a formal inconsistency, which in practice leads to unrealistically high tumor doses. We then introduce a more realistic approach that essentially exploits all the experimental information available from survival experiments.
View Article and Find Full Text PDFIn the present study the therapeutic effect and potential toxicity of the novel "Sequential" boron neutron capture therapy (Seq-BNCT) for the treatment of oral cancer was evaluated in the hamster cheek pouch model at the RA-3 Nuclear Reactor. Two groups of animals were treated with "Sequential" BNCT, i.e.
View Article and Find Full Text PDFPurpose: DNA lesions produced by boron neutron capture therapy (BNCT) and those produced by gamma radiation in a colon carcinoma cell line were analyzed. We have also derived the relative biologic effectiveness factor (RBE) of the neutron beam of the RA-3- Argentine nuclear reactor, and the compound biologic effectiveness (CBE) values for p-boronophenylalanine ((10)BPA) and for 2,4-bis (α,β-dihydroxyethyl)-deutero-porphyrin IX ((10)BOPP).
Methods And Materials: Exponentially growing human colon carcinoma cells (ARO81-1) were distributed into the following groups: (1) BPA (10 ppm (10)B) + neutrons, (2) BOPP (10 ppm (10)B) + neutrons, (3) neutrons alone, and (4) gamma rays ((60)Co source at 1 Gy/min dose-rate).
In recent years, many efforts have been made to study the performance of treatment planning systems in deriving an accurate dosimetry of the complex radiation fields involved in boron neutron capture therapy (BNCT). The computational model of the patient's anatomy is one of the main factors involved in this subject. This work presents a detailed analysis of the performance of the 1 cm based voxel reconstruction approach.
View Article and Find Full Text PDFThe microdosimetry of (10)B thermal neutron capture reactions should be considered as an essential step to be followed before studying the radiobiological aspects of boron neutron capture therapy. The boron dose itself is insufficient as the only quantity used to describe the biological effectiveness of the (10)B reaction for two important reasons: the specific microdistribution that the (10)B carrier compound exhibits at the cellular level and the primarily stochastic nature of the energy deposition process, which influences the biological response to the particulate radiation. In this work, these two aspects are analyzed in detail and an innovative rigorous analytical framework is developed in the microdosimetry domain.
View Article and Find Full Text PDFA phase I trial was designed to evaluate normal tissue tolerance to neutron capture therapy (NCT); tumor response was also followed as a secondary endpoint. Between July 1996 and May 1999, 24 subjects were entered into a phase I trial evaluating cranial NCT in subjects with primary or metastatic brain tumors. Two subjects were excluded due to a decline in their performance status and 22 subjects were irradiated at the MIT Nuclear Reactor Laboratory.
View Article and Find Full Text PDF