Publications by authors named "Guobao Wang"

Background: Particulate matter (PM2.5) has been implicated in the development of membranous nephropathy (MN), but the underlying mechanism has yet to be fully understood. Oxidative stress is an essential factor of PM2.

View Article and Find Full Text PDF

Purpose: Dual-energy (DE) CT enables material decomposition by using two different x-ray energies and may be combined with PET for improved multimodality imaging. However, this increases radiation dose and may require a hardware upgrade due to the added second x-ray CT scan. The recently proposed PET-enabled DECT method allows dual-energy imaging using a conventional PET/CT scanner without the need to change scanner hardware or increase radiation exposure.

View Article and Find Full Text PDF
Article Synopsis
  • - Metabolic dysfunction-associated steatohepatitis (MASH) is an increasing global health issue that emphasizes the need for non-invasive testing methods.
  • - Dynamic F-fluorodeoxyglucose (FDG) PET/CT imaging has been shown to effectively identify MASH by assessing liver glucose transport rates and CT image characteristics.
  • - Combining FDG-PET with the serum fibrosis-4 (FIB-4) test enhances the ability to differentiate between types of MASH, providing insights into its key features: steatosis, inflammation, and fibrosis, while future research may help predict MASH severity and related health issues.
View Article and Find Full Text PDF

Unlabelled: Quantitative total-body PET imaging of blood flow can be performed with freely diffusible flow radiotracers such as O-water and C-butanol, but their short half-lives necessitate close access to a cyclotron. Past efforts to measure blood flow with the widely available radiotracer F-fluorodeoxyglucose (FDG) were limited to tissues with high F-FDG extraction fraction. In this study, we developed an early-dynamic F-FDG PET method with high temporal resolution kinetic modeling to assess total-body blood flow based on deriving the vascular transit time of F-FDG and conducted a pilot comparison study against a C-butanol reference.

View Article and Find Full Text PDF

The interpretation of clinical oncologic PET studies has historically used static reconstructions based on SUVs. SUVs and SUV-based images have important limitations, including dependence on uptake times and reduced conspicuity of tracer-avid lesions in organs with high background uptake. The acquisition of dynamic PET images enables additional PET reconstructions via Patlak modeling, which assumes that a tracer is irreversibly trapped by tissues of interest.

View Article and Find Full Text PDF

Brown adipose tissue (BAT) in rodents appears to be an important tissue for the clearance of plasma branched-chain amino acids (BCAAs) contributing to improved metabolic health. However, the role of human BAT in plasma BCAA clearance is poorly understood. Here, we evaluate patients with prostate cancer who underwent positron emission tomography-computed tomography imaging after an injection of F-fluciclovine (L-leucine analog).

View Article and Find Full Text PDF

Blood-brain barrier (BBB) disruption is involved in the pathogenesis and progression of many neurological and systemic diseases. Non-invasive assessment of BBB permeability in humans has mainly been performed with dynamic contrast-enhanced magnetic resonance imaging, evaluating the BBB as a structural barrier. Here, we developed a novel non-invasive positron emission tomography (PET) method in humans to measure the BBB permeability of molecular radiotracers that cross the BBB through different transport mechanisms.

View Article and Find Full Text PDF

Standard Patlak plot is widely used to describe FDG kinetics for dynamic PET imaging. Whole-body Patlak parametric imaging remains constrained due to the need for a full-time input function. Here, we demonstrate the Relative Patlak (RP) plot, which eliminates the need for the early-time input function, for total-body parametric imaging and its application to clinical 20-min scan acquired in list-mode.

View Article and Find Full Text PDF

A major challenge in prevention and early treatment of organ fibrosis is the lack of valuable tools to assess the evolving profibrotic maladaptive repair after injury in vivo in a non-invasive way. Here, using acute kidney injury (AKI) as an example, we tested the utility of fibroblast activation protein (FAP) imaging for dynamic assessment of maladaptive repair after injury. The temporospatial pattern of kidney FAP expression after injury was first characterized.

View Article and Find Full Text PDF

Immunotherapies, especially checkpoint inhibitors such as anti-programmed cell death protein 1 (anti-PD-1) antibodies, have transformed cancer treatment by enhancing the immune system's capability to target and kill cancer cells. However, predicting immunotherapy response remains challenging. F-arabinosyl guanine ([F]F-AraG) is a molecular imaging tracer targeting activated T cells, which may facilitate therapy response assessment by noninvasive quantification of immune cell activity within the tumor microenvironment and elsewhere in the body.

View Article and Find Full Text PDF

Accurate quantification of tau binding from F-PI-2620 PET requires kinetic modeling and an input function. Here, we implemented a non-invasive Image-derived input function (IDIF) derived using the state-of-the-art total-body uEXPLORER PET/CT scanner to quantify tau binding and tracer delivery rate from F-PI-2620 in the brain. Additionally, we explored the impact of scan duration on the quantification of kinetic parameters.

View Article and Find Full Text PDF

Combining dual-energy computed tomography (DECT) with positron emission tomography (PET) offers many potential clinical applications but typically requires expensive hardware upgrades or increases radiation doses on PET/CT scanners due to an extra X-ray CT scan. The recent PET-enabled DECT method allows DECT imaging on PET/CT without requiring a second X-ray CT scan. It combines the already existing X-ray CT image with a 511 keV γ -ray CT (gCT) image reconstructed from time-of-flight PET emission data.

View Article and Find Full Text PDF

Unlabelled: Dynamic PET allows quantification of physiological parameters through tracer kinetic modeling. For dynamic imaging of brain or head and neck cancer on conventional PET scanners with a short axial field of view, the image-derived input function (ID-IF) from intracranial blood vessels such as the carotid artery (CA) suffers from severe partial volume effects. Alternatively, optimization-derived input function (OD-IF) by the simultaneous estimation (SIME) method does not rely on an ID-IF but derives the input function directly from the data.

View Article and Find Full Text PDF
Article Synopsis
  • A study involving 1,915 peritoneal dialysis patients in China aimed to examine the link between time spent within the target range of serum phosphorus levels and mortality risk.
  • The research found that longer durations with serum phosphorus levels between 1.13-1.78 mmol/L were associated with lower rates of all-cause and cardiovascular mortality, as well as decreased withdrawal from dialysis treatment.
  • These results emphasize the importance of maintaining appropriate serum phosphorus levels to potentially improve survival outcomes for patients on peritoneal dialysis.
View Article and Find Full Text PDF

The lungs are supplied by both the pulmonary arteries carrying deoxygenated blood originating from the right ventricle and the bronchial arteries carrying oxygenated blood downstream from the left ventricle. However, this effect of dual blood supply has never been investigated using PET, partially because the temporal resolution of conventional dynamic PET scans is limited. The advent of PET scanners with a long axial field of view, such as the uEXPLORER total-body PET/CT system, permits dynamic imaging with high temporal resolution (HTR).

View Article and Find Full Text PDF

Dual-energy computed tomography (DECT) enables material decomposition for tissues and produces additional information for PET/CT imaging to potentially improve the characterization of diseases. PET-enabled DECT (PDECT) allows the generation of PET and DECT images simultaneously with a conventional PET/CT scanner without the need for a second x-ray CT scan. In PDECT, high-energy -ray CT (GCT) images at 511 keV are obtained from time-of-flight (TOF) PET data and are combined with the existing x-ray CT images to form DECT imaging.

View Article and Find Full Text PDF
Article Synopsis
  • Spectral computed tomography (CT) is an advanced version of conventional CT that enhances imaging capabilities through dual-energy and photon-counting methods.
  • These methods offer benefits like improved image quality, better material analysis, and enhanced feature measurement compared to traditional CT.
  • Despite these advancements, spectral CT faces challenges like data and image artifacts, leading to a growing use of machine learning techniques to resolve these issues in clinical settings.
View Article and Find Full Text PDF

Biological aqua crust (biogenic aqua crust-BAC) is a potentially sustainable solution for metal(loid) bioremediation in global water using solar energy. However, the key geochemical factors and underlying mechanisms shaping microbial communities in BAC remain poorly understood. The current study aimed at determining the in situ metal(loid) distribution and the key geochemical factors related to microbial community structure and metal(loid)-related genes in BAC of a representative Pb/Zn tailing pond.

View Article and Find Full Text PDF

X-ray computed tomography (CT) in PET/CT is commonly operated with a single energy, resulting in a limitation of lacking tissue composition information. Dual-energy (DE) spectral CT enables material decomposition by using two different x-ray energies and may be combined with PET for improved multimodality imaging, but would either require hardware upgrade or increase radiation dose due to the added second x-ray CT scan. Recently proposed PET-enabled DECT method allows dual-energy spectral imaging using a conventional PET/CT scanner without the need for a second x-ray CT scan.

View Article and Find Full Text PDF

Background: Hyaluronic acid (HA) dermal fillers injection is a common procedure in patients with cosmetic needs. Concomitant pain is a major complaint among patients undergoing HA filler injections. Relevant research is limited and there is no consensus on pain management of dermal filler injection.

View Article and Find Full Text PDF

Objective: The present study aimed to evaluate the effectiveness of minimally invasive 980 nm laser-assisted lipolysis and skin tightening in lower eyelid blepharoplasty of Asian patients.

Methods: Patients with mild and moderate degree of eyebags underwent 980 nm laser-assisted lipolysis via lower eyelid stab incision between December 2017 and December 2019. Evaluation criteria was reviewed by photographs taken preoperatively and 6 months postoperatively in accordance with guidelines of Global Aesthetic Improvement Scale, the patient's perspective from the questionnaire with the perception of reduction in eyebags size, the average perception of improvement in skin tightening, and the patient overall satisfaction, all with a score of 1 to 5 (5 being the most noticeable and very satisfied) and complications such as dyspigmentation, hematoma, prolonged edema, skin bump and thermal burn were documented as well.

View Article and Find Full Text PDF

Background And Aim: To date, few studies have investigated the association between dietary manganese intake and the risk of hypertension, so the prospective relationship of dietary manganese intake and new-onset hypertension remains uncertain. We aimed to investigate the association between dietary manganese intake and the risk of new-onset hypertension in the general Chinese population.

Methods And Results: This prospective cohort study included 12,177 participants who were free of hypertension at baseline from China Health and Nutrition Survey (CHNS).

View Article and Find Full Text PDF

Background: There are challenges for beginners to identify standard biliopancreatic system anatomical sites on endoscopic ultrasonography (EUS) images. Therefore, the authors aimed to develop a convolutional neural network (CNN)-based model to identify standard biliopancreatic system anatomical sites on EUS images.

Methods: The standard anatomical structures of the gastric and duodenal regions observed by EUS was divided into 14 sites.

View Article and Find Full Text PDF

Rubidium laser optically pumped magnetometers (OPMs) are widely used magnetic sensors based on the Zeeman effect, laser pumping, and magnetic resonance principles. They measure the magnetic field by measuring the magnetic resonance signal passing through a rubidium atomic gas cell. The quality of the magnetic resonance signal is a necessary condition for a magnetometer to achieve high sensitivity.

View Article and Find Full Text PDF