Publications by authors named "Gunnarsen L"

Objectives: To examine changes and socioeconomic patterns in indicators of a poor indoor environment in 2000 and 2021.

Study Design: Cross-sectional data from the Danish Health and Morbidity Survey in 2000 and 2021.

Methods: The study included 27,068 participants.

View Article and Find Full Text PDF

Background: More knowledge is needed on the risk of developing chronic obstructive pulmonary disease (COPD) associated with housing conditions and indoor environment based on cohort studies with a long follow-up time.

Objective: To examine the association between housing conditions and indoor environment and the risk of developing COPD.

Methods: In this cohort study, we followed 11,590 individuals aged ≥ 30 years free of COPD at baseline.

View Article and Find Full Text PDF

Buildings are constructed and operated to satisfy human needs and improve quality of life. Good indoor air quality (IAQ) and thermal comfort are prerequisites for human health and well-being. For their provision, buildings often rely on heating, ventilation, and air conditioning (HVAC) systems, which may lead to higher energy consumption.

View Article and Find Full Text PDF

The increasing prevalence of reported annoyances in the indoor environment threatens public health. This study aimed to investigate the association between perceived annoyances from the home environment and respiratory infections among individuals with and without asthma or chronic obstructive pulmonary disease (COPD). A total of 16,688 individuals from the Danish Health and Morbidity Survey initiated in 2000 were grouped according to their patterns of perceived annoyances.

View Article and Find Full Text PDF

Background: Polychlorinated biphenyls (PCBs) are biopersistent chemicals classified as human carcinogens. This classification is primarily based on evidence on higher-chlorinated PCBs found in food. The carcinogenic potential of airborne lower-chlorinated PCBs remains largely unexplored.

View Article and Find Full Text PDF

The indoor environment is composed of several exposures existing simultaneously. Therefore, it might be useful to combine exposures into common combined measures when used to assess the association with health. The aim of our study was to identify patterns of the perceived indoor environment.

View Article and Find Full Text PDF

Work-related stress and certain lifestyles have been associated with sickness absence among employees. We analysed relations between stress and lifestyles (as risk factors) and short-term sickness absence among employees of a large Danish industrial company. Moreover, we analysed the impact of risk factors on short-term sickness absence.

View Article and Find Full Text PDF

As part of an investigation of the total indoor exposure of residents in PCB contaminated apartments in a building estate in Denmark, 73 homes were visited. Samples of air, vacuum cleaner dust and surface wipes were taken and analysed for 15 PCB congeners. The 53 apartments located in high-rise buildings with indoor PCB containing sealants showed significant elevated total concentrations of PCB in air, dust and surface wipes compared to 20 reference homes.

View Article and Find Full Text PDF

Exposure to polychlorinated biphenyls (PCB) in buildings constructed with PCB-containing materials can lead to increased body burden of PCB for building users. Exposure to PCB from building related sources was assessed by measuring PCB in serum and hand wipes in two groups of tenants living in the same building estate in apartments constructed with and without PCB. The median serum levels of the sum of 19 PCB congeners was 777 ng/g lw (5-95th percentile: 219-2576 ng/g lw) for the exposed group and 282 ng/g lw (5-95th percentile: 49.

View Article and Find Full Text PDF

Polychlorinated biphenyl (PCB) contamination of buildings continues to pose an exposure threat, even decades after their application in the form of calks and other building materials. In this research, we investigate the ability of clothing to sorb PCBs from contaminated air and thereby influence exposure. The equilibrium concentration of PCB-28 and PCB-52 was quantified for nine used clothing fabrics exposed for 56 days to air in a Danish apartment contaminated with PCBs.

View Article and Find Full Text PDF

Polychlorinated biphenyls (PCBs) have been used in flexible construction products from the 1950s to the 1970s. Despite a relatively low vapour pressure, PCBs have over the years emitted to the indoor air and adsorbed to other surfaces, creating tertiary sources. While necessary to protect the environment and health of building occupants, remediation of the contaminated buildings is an expensive and difficult process.

View Article and Find Full Text PDF

Polychlorinated biphenyls (PCBs) have been found to be persistent in the environment and possibly harmful. Many buildings are characterized with high PCB concentrations. Knowledge about partitioning between primary sources and building materials is critical for exposure assessment and practical remediation of PCB contamination.

View Article and Find Full Text PDF

To explore associations of exposure to ambient and indoor air particulate and bio-aerosol pollutants with cardiovascular and respiratory disease markers, we utilized seven repeated measurements from 48 elderly subjects participating in a 4-week home air filtration study. Microvascular function (MVF), lung function, blood leukocyte counts, monocyte adhesion molecule expression, C-reactive protein, Clara cell protein (CC16) and surfactant protein-D (SPD) were examined in relation to exposure preceding each measurement. Exposure assessment included 48-h urban background monitoring of PM10, PM2.

View Article and Find Full Text PDF

The isothiazolinone preservatives methylisothiazolinone (MI), methylchloroisothiazolinone (MCI), and benzisothiazolinone (BIT) are used in a wide variety of products including paint and cosmetics, and they are known to cause allergic contact dermatitis. Among painters they are one of the most common causes of contact dermatitis. Furthermore, they are all volatile, and severe reactions caused by emissions of especially MI from paint have been reported recently.

View Article and Find Full Text PDF

Background: Exposure to particulate air pollution increases respiratory and cardiovascular morbidity and mortality, especially in elderly, possibly through inflammation and vascular dysfunction.

Methods: We examined potential beneficial effects of indoor air filtration in the homes of elderly, including people taking vasoactive drugs.Forty-eight nonsmoking subjects (51 to 81 years) in 27 homes were included in this randomized, double-blind, crossover intervention study with consecutive two-week periods with or without the inclusion of a high-efficiency particle air filter in re-circulating custom built units in their living room and bedroom.

View Article and Find Full Text PDF

Background: In the1950s-1970s polychlorinated biphenyls (PCBs) were used in several countries as plasticizers in elastic sealants in buildings.

Objective: The primary objective was to study whether residents of PCB-contaminated dwellings had higher plasma levels of PCBs than their neighbours in non-contaminated dwellings. The secondary objective was to study possible associations between concentrations of PCBs in the indoor air and in the plasma of residents.

View Article and Find Full Text PDF

Radon-222 gas arises from the radioactive decay of radium-226 and has a half-life of 3.8 days. This gas percolates up through soil into buildings, and if it is not evacuated, there can be much higher exposure levels indoors than outdoors, which is where human exposure occurs.

View Article and Find Full Text PDF

Selection of sampling device, sampling location and period are important first steps in the measurement of exposure to bioaerosols in indoor air. The steps following the sampling include treatment of samples and laboratory analysis. In this study, settling bacteria, endotoxin, fungi and serine protease have been measured in Danish homes using Electrostatic Dust Fall Collectors (EDCs).

View Article and Find Full Text PDF

Twenty-four congeners of polychlorinated biphenyls (PCBs) were measured in 83 air samples and 20 elastic sealants samples of apartments with PCB-containing sealants. In addition, PCBs were measured in 21 air samples from reference apartments located in an uncontaminated section of the same estate. The PCB(tot) levels in the air of the contaminated section were 168-3843 ng m(-3) (mean: 1030 ng m(-3)), while the mean levels in the reference apartments were 6.

View Article and Find Full Text PDF

Organochlorine pesticides are present in the environment and suspected of causing serious health effects. Diet has been the main exposure source, but indoor source release is gaining focus. Within a monitoring study of polychlorinated biphenyls of Danish buildings built during the 1960s and 1970s, we coincidently determined extreme levels of dichlorodiphenyltrichloroethane (DDT) levels in two of ten random samples.

View Article and Find Full Text PDF

Unlabelled: More than 30 years after the First International Indoor Climate Symposium, ten researchers from the USA, Slovakia, Sweden, and Denmark gathered to review the current status of indoor environmental research. We initiated our review with discussions during the 1-day meeting and followed that with parallel research and writing efforts culminating with internal review and revision cycles. In this paper, we present our choices for the most important research findings on indoor environmental quality from the past three decades followed by a discussion of the most important research questions in our field today.

View Article and Find Full Text PDF

Unlabelled: The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings received a retrospective questionnaire about BRS (2301 respondents).

View Article and Find Full Text PDF

Rationale: Exposure to particulate matter is associated with risk of cardiovascular events, possibly through endothelial dysfunction, and indoor air may be most important.

Objectives: We investigated effects of controlled exposure to indoor air particles on microvascular function (MVF) as the primary endpoint and biomarkers of inflammation and oxidative stress as secondary endpoints in a healthy elderly population.

Methods: A total of 21 nonsmoking couples participated in a randomized, double-blind, crossover study with two consecutive 48-hour exposures to either particle-filtered or nonfiltered air (2,533-4,058 and 7,718-12,988 particles/cm(3), respectively) in their homes.

View Article and Find Full Text PDF

The emission of di-2-ethylhexyl phthalate (DEHP) from a PVC flooring was studied for up to 472 days in both the FLEC (Field and Laboratory Emission Cell) and the CLIMPAQ (Chamberfor Laboratory Investigations of Materials, Pollution, and Air Quality). The loading of the CLIMPAQs was varied but was constant in the FLECs. The sorption properties of FLEC and CLIMPAQ were investigated using different methods.

View Article and Find Full Text PDF

The main objective of this study was to generate quantitative and qualitative emission data on phthalates from different materials. To achieve this the existing (Chamber for Laboratory Investigations of Materials, Pollution and Air Quality) Climpaq-based procedure for simplified measurements of emissions of plasticizer from PVC and other plasticized materials was modified. It was applied to a range of products.

View Article and Find Full Text PDF