Publications by authors named "Gulam Musharaf"

Background: Prior experience with the Cook (Cook Inc, Bloomington, IN) Teflon rigid catheter (CTC) showed it to be a suboptimal access for acute peritoneal dialysis (PD) treatment in infants and children because of the frequency of catheter-related complications associated with its use. The objective of this study is to report our experience with the bedside-placed flexible Cook Mac-Loc Multipurpose Drainage catheter (CMMDC) for acute PD in critically ill infants, comparing it with the historic Tenckhoff catheter (TC) and CTC use.

Study Design: Retrospective cohort study.

View Article and Find Full Text PDF

Peritonitis and catheter-related (exit-site/tunnel) infections are major causes of morbidity in children receiving peritoneal dialysis (PD). Our objective was to evaluate the impact of a combination of prophylactic measures on the rate of peritonitis and catheter-related infections subsequent to their implementation in 2001. This is a single center review of incident patients who received automated peritoneal dialysis (APD) from 1997 to 2004.