Publications by authors named "Guiseppi-Elie A"

Article Synopsis
  • Physical vapor deposition creates organic glasses with high kinetic stability, which can slowly transition to supercooled liquids when heated.
  • The study investigates the rejuvenation of vapor-deposited methyl-m-toluate glasses after 6 hours of annealing at a temperature close to their glass transition temperature (Tg), finding moderate glasses show rejuvenation, while highly stable glasses do not show expected changes.
  • Surprisingly, annealing lead to increased storage component of dielectric susceptibility in stable glasses without increases in the loss component, indicating short-term rejuvenation affects high-frequency relaxation processes; simulations showed no rejuvenation in similarly stable glasses within the same time frame.
View Article and Find Full Text PDF

In 2014, as the Founding Editor-in-Chief, I welcomed you to the first issue of a new open access MDPI journal, [...

View Article and Find Full Text PDF

The emergence of remote health monitoring and increased at-home care emphasizes the importance of patient adherence outside the clinical setting. This is particularly pertinent in the treatment of Attention Deficit Hyperactivity Disorder (ADHD) in pediatric patients, as the population inherently has difficulty remembering and initiating treatment tasks. Neurostimulation is an emerging treatment modality for pediatric ADHD and requires strict adherence to a treatment regimen to be followed in an at-home setting.

View Article and Find Full Text PDF

Glassy films of methyl-m-toluate have been vapor deposited onto a substrate equipped with interdigitated electrodes, facilitating in situ dielectric relaxation measurements during and after deposition. Samples of 200 nm thickness have been deposited at rates of 0.1 nm/s at a variety of deposition temperatures between 40 K and Tg = 170 K.

View Article and Find Full Text PDF

Vascularized composite allotransplantation can improve quality of life and restore functionality. However, the complex tissue composition of vascularized composite allografts (VCAs) presents unique clinical challenges that increase the likelihood of transplant rejection. Under prolonged static cold storage, highly damage-susceptible tissues such as muscle and nerve undergo irreversible degradation that may render allografts non-functional.

View Article and Find Full Text PDF

Dielectric relaxation was used to characterize the ability of vapor-deposited mixtures of - and decahydroisoquinoline (DHIQ) to form glasses with a high kinetic stability. Vapor-deposited mixtures are technologically relevant, and the effect of mixing on glass stability is a relatively unexplored area. Mixed isomers and pure -DHIQ form highly stable glasses that isothermally transform in approximately 10 τ (where τ is the structural relaxation time of the supercooled liquid).

View Article and Find Full Text PDF

Electrical stimulation, the application of an electric field to cells and tissues grown in culture to accelerate growth and tight junction formation among endothelial cells, could be impactful in cardiovascular tissue engineering, allotransplantation, and wound healing. Using Electrical Cell Stimulation And Recording Apparatus (ECSARA), the exploration of the stimulatory influences of electric fields of different magnitude and frequencies on growth and proliferation, trans endothelial electrical resistance (TEER) and gene expression of human endothelia cells (HUVECs) were explored. Within the range of endogenous electrical pulses studied, frequency was found to be more significant ( = 0.

View Article and Find Full Text PDF

Vascularized composite allotransplantation addresses injuries to complex anatomical structures such as the face, hand, and abdominal wall. Prolonged static cold storage of vascularized composite allografts (VCA) incurs damage and imposes transportation limits to their viability and availability. Tissue ischemia, the major clinical indication, is strongly correlated with negative transplantation outcomes.

View Article and Find Full Text PDF

Bioelectrical impedance analysis and bioelectrical impedance spectroscopy (BIA/BIS) of tissues reveal important information on molecular composition and physical structure that is useful in diagnostics and prognostics. The heterogeneity in structural elements of cells, tissues, organs, and the whole human body, the variability in molecular composition arising from the dynamics of biochemical reactions, and the contributions of inherently electroresponsive components, such as ions, proteins, and polarized membranes, have rendered bioimpedance challenging to interpret but also a powerful evaluation and monitoring technique in biomedicine. BIA/BIS has thus become the basis for a wide range of diagnostic and monitoring systems such as plethysmography and tomography.

View Article and Find Full Text PDF

Flexible electronics require elastomeric and conductive biointerfaces with native tissue-like mechanical properties. The conventional approaches to engineer such a biointerface often utilize conductive nanomaterials in combination with polymeric hydrogels that are cross-linked using toxic photoinitiators. Moreover, these systems frequently demonstrate poor biocompatibility and face trade-offs between conductivity and mechanical stiffness under physiological conditions.

View Article and Find Full Text PDF

Myocardial infarction remains the leading cause of death in the western world. Since the heart has limited regenerative capabilities, several cardiac tissue engineering (CTE) strategies have been proposed to repair the damaged myocardium. A novel electrospun construct with aligned and electroconductive fibers combining gelatin, poly(lactic-co-glycolic) acid and polypyrrole that may serve as a cardiac patch is presented.

View Article and Find Full Text PDF

A number of investigators have explored the use of value of information (VOI) analysis to evaluate alternative information collection procedures in diverse decision-making contexts. This paper presents an analytic framework for determining the value of toxicity information used in risk-based decision making. The framework is specifically designed to explore the trade-offs between cost, timeliness, and uncertainty reduction associated with different toxicity-testing methodologies.

View Article and Find Full Text PDF

The dielectric relaxation behavior of the molecular glass former butyronitrile is revisited by measuring both bulk samples cooled from the melt and samples obtained by physical vapor deposition. We find that the dielectric constant in the viscous regime of the bulk liquid is much higher than reported previously, reaching ε = 63 at T = 103 K, i.e.

View Article and Find Full Text PDF

Regulatory agencies are required to evaluate the impacts of thousands of chemicals. Toxicological tests currently used in such evaluations are time-consuming and resource intensive; however, advances in toxicology and related fields are providing new testing methodologies that reduce the cost and time required for testing. The selection of a preferred methodology is challenging because the new methodologies vary in duration and cost, and the data they generate vary in the level of uncertainty.

View Article and Find Full Text PDF

Attention deficit hyperactivity disorder (ADHD) is a pervasive condition affecting persons across all age groups, although it is primarily diagnosed in children. This neurological condition affects behavior, learning, and social adjustment and requires specific symptomatic criteria to be fulfilled for diagnosis. ADHD may be treated with a combination of psychological or psychiatric therapeutic interventions, but it often goes unattended.

View Article and Find Full Text PDF

Endothelial mechanobiology is a key consideration in the progression of vascular dysfunction, including atherosclerosis. However mechanistic connections between the clinically associated physical stimuli, vessel stiffness and shear stress, and how they interact to modulate plaque progression remain incompletely characterized. Vessel-chip systems are excellent candidates for modeling vascular mechanobiology as they may be engineered from the ground up, guided by the mechanical parameters present in human arteries and veins, to recapitulate key features of the vasculature.

View Article and Find Full Text PDF

Depositing a simple organic molecular glass-former 2-methyltetrahydrofuran (MTHF) onto an interdigitated electrode device via physical vapor deposition gives rise to an unexpected variety of states, as revealed by dielectric spectroscopy. Different preparation parameters, such as deposition temperature, deposition rate, and annealing conditions, lead, on the one hand, to an ultrastable glass and, on the other hand, to a continuum of newfound further states. Deposition below the glass transition temperature of MTHF leads to loss profiles with shape parameters and peak frequencies that differ from those of the known bulk MTHF.

View Article and Find Full Text PDF

Formed in 2000 at Virginia Commonwealth University, the Center for Bioelectronics, Biosensors and Biochips (C3B®) has subsequently been located at Clemson University and at Texas A&M University. Established as an industry-university collaborative center of excellence, the C3B has contributed new knowledge and technology in the areas of i) molecular bioelectronics, ii) responsive polymers, iii) multiplexed biosensor systems, and iv) bioelectronic biosensors. Noteworthy contributions in these areas include i) being the first to report direct electron transfer of oxidoreductase enzymes enabled by single walled carbon nanotubes and colloidal clays, ii) the molecular level integration of inherently conductive polymers with bioactive hydrogels using bi-functional monomers such as poly(pyrrole-co-3-pyrrolylbutyrate-conj-aminoethylmethacrylate) [PyBA-conj-AEMA] and 3-(1-ethyl methacryloylate)aniline to yield hetero-ladder electroconductive hydrogels, iii) the development of a multi-analyte physiological status monitoring biochip, and iv) the development of a bioanalytical Wien-bridge oscillator for the fused measurement to lactate and glucose.

View Article and Find Full Text PDF

By measuring the increments of dielectric capacitance (ΔC) and dissipation (Δtan δ) during physical vapor deposition of a 110 nm film of a molecular glass former, we provide direct evidence of the mobile surface layer that is made responsible for the extraordinary properties of vapor deposited glasses. Depositing at a rate of 0.1 nm s onto a substrate at T = 75 K = 0.

View Article and Find Full Text PDF

In situ AC nanocalorimetry and dielectric spectroscopy were used to analyze films of vapor-deposited triphenyl phosphite. The goal of this work was to investigate the properties of vapor-deposited glasses of this known polyamorphic system and to determine which liquid is formed when the glass is heated. We find that triphenyl phosphite forms a kinetically stable glass when prepared at substrate temperatures of 0.

View Article and Find Full Text PDF
Article Synopsis
  • GQDs and CQDs are advanced nanomaterials known for their unique quantum properties and biocompatibility, making them valuable in fields like biosensing and analyte detection.
  • This review focuses on the recent advancements in biotransducers and biosensors utilizing these materials, highlighting their interactions with biomolecules to enhance detection efficiency.
  • It also provides insights into biosensor designs, discusses key properties of GQDs and CQDs, and offers suggestions to drive future research in the development of quality and safety-focused biosensors.
View Article and Find Full Text PDF

Background: To introduce the Hemorrhage Intensive Severity and Survivability (HISS) score, based on the fusion of multi-biomarker data; glucose, lactate, pH, potassium, and oxygen tension, to serve as a patient-specific attribute in hemorrhagic trauma.

Materials And Methods: One hundred instances of Sensible Fictitious Rationalized Patient (SFRP) data were synthetically generated and the HISS score assigned by five clinically active physician experts (100 [5]). The HISS score stratifies the criticality of the trauma patient as; low(0), guarded(1), elevated(2), high(3) and severe(4).

View Article and Find Full Text PDF

Biofabrication techniques such as microlithography and 3-D bioprinting have emerged in recent years as technologies capable of rendering complex, biocompatible constructs for biosensors, tissue and regenerative engineering and bioelectronics. While instruments and processes have been the subject of immense advancement, multifunctional bioinks have received less attention. A novel photocrosslinkable, hybrid bioactive and inherently conductive bioink formed from poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) nanomaterials within poly(2-hydroxyethyl methacrylate-co-polyethyleneglycol methacrylate) p(HEMA-co-EGMA) was used to render complex hydrogel constructs through microlithographic fabrication and 3-D printing.

View Article and Find Full Text PDF

A pH-responsive, poly(2-hydroxyethyl methacrylate) [poly(HEMA)]-based hydrogel has been fashioned into an impedimetric pH sensor for the continual measurement and monitoring of tissue acidosis that can arise due to hemorrhaging trauma. Four hydrogel systems molecularly engineered to influence water distribution and ionic abundance were studied: a cationogenic primary amine, -(2-aminoethyl) methacrylate (AEMA), a tertiary amine moiety, ,-(2-dimethylamino)ethyl methacrylate (DMAEMA), and a combined AEMA-DMAEMA formulation. Electrochemical impedance spectroscopy (EIS) of hydrogel discs held between platinized Type 304 stainless steel mesh electrodes in pH-adjusted 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid sodium salt (HEPES) buffer and equivalent circuit modeling indicated that the AEMA hydrogel had the highest sensitivity containing the relevant pathophysiological range (pH 7.

View Article and Find Full Text PDF