Computer-aided manufacturing (CAM) technology allows the use of different manufacturing techniques. This in vitro study aimed to evaluate the marginal fit of temporary restorations manufactured using conventional chairside methods, milling, and three-dimensional printing. Fifteen 3-element temporary restorations specimens were produced and categorized into three groups: non-digital, obtained using the conventional chairside method (GC); milled (GM); and three-dimensionally printed (GP).
View Article and Find Full Text PDFPurpose: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers.
Materials And Methods: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner.
Mist nets are one of the most widely used techniques in the study of birds and bats worldwide. However, a number of risks are involved, including opportunistic predation. Given this potential cost, here we: (1) review the global literature to understand the factors that might contribute to predation risk for birds and bats captured in mist nets; (2) review existing guidelines for best practice use of mist nets; and (3) based on our reviews, recommend new guidelines for the use of mist nets to minimize the risk of opportunistic predation.
View Article and Find Full Text PDFBackground: The objective was to compare physic-mechanical properties of different materials used for temporary restorations.
Material And Methods: Protemp 4/bisacrylic resin, Jet/acrylic resin, and Nexdent C&B/3D-printed resin samples (10mm diameter x 2mm thickness) were analyzed for surface roughness and color stability tests (baseline, after 5 thousand brushing cycles; and after artificial aging in water at 60oC for 24 hours) and Knoop microhardness. All data were checked for normality using Shapiro-Wilk test.
Objectives: This in vitro comparative study aimed to evaluate the physical and mechanical properties of four 3D-printed resins with two different thickness layers.
Methods: Four printed resins (VarseoSmile Crown Plus, VSC; NexDent C&B MFH, MFH; Nanolab 3D, NNL; and Resilab 3D Temp, RSL) were printed with 50 µm and 100 µm layer thickness, resulting in 80 bars measuring 25 × 2×2 mm. The specimens underwent a Raman spectroscopy for degree of conversion, confocal laser scanning microscopy for surface roughness (Sa), three-point bending test for flexural strength and elastic modulus, and a Vickers hardness test (VHN).
The discovery and tracking of antimicrobial resistance genes are essential for understanding the evolution of bacterial resistance and restraining its dispersion. Mammaliicoccus sciuri (formerly Staphylococcus sciuri) is the most probable evolutionary repository of the mecA gene, that later disseminated to S. aureus.
View Article and Find Full Text PDFStatement Of Problem: Postpolymerization methods influence the properties of 3-dimensionally (3D) printed materials. Nevertheless, it is a time-consuming step that could lead dentists to avoid the chairside use of 3D printing. Information assessing the impact of different postpolymerization workflows on flexural strength and color stability is sparse.
View Article and Find Full Text PDFStatement Of Problem: When 3-dimensional printing casts, the operator can change the type of resin and the printing layer thickness, reducing the fabrication time. However, how these parameters affect the accuracy of 3-dimensionally printed casts is unknown.
Purpose: The purpose of this in vitro study was to evaluate the accuracy of 3-dimensionally printed casts by using a stereolithography (SLA) 3-dimensional printer (Forms2) with 3 different layer thickness (25, 50, and 100 μm) and 2 different resins (Gray and Cast) and by comparing the time to obtain each cast.
J Esthet Restor Dent
December 2021
Introductions: Intraoral scanner has been widely used for implant impression in partially edentulous cases; however, its accuracy in the impression of full-arch implant is still questionable.
Clinical Report: This clinical report presents a technique to check the accuracy of intraoral scanning for complete-arch implant restorations using an implant index cast (The Glossary of Prosthodontic Terms 9th Edition) and a three-dimensional printed cast. A clinical case of immediate loading on a maxillary edentulous patient illustrates the application of an implant index cast in implant fixed complete dentures (IFCDs).
The effect of the phosphorus (P) and glyphosate interactions on the growth and nutrition of Arabica coffee cultivars (Coffea arabica), as well as on the control of Ipomoea grandifolia and Urochloa decumbens, was evaluated. Catuaí-Amarelo/IAC-62 and Catuaí-Vermelho/IAC-144 cultivars did not show glyphosate poisoning, regardless of the soil P content. However, glyphosate reduced the growth of Catuaí-Vermelho/IAC-144.
View Article and Find Full Text PDFIntroduction: A disharmonious smile results from excessive gingival exposure or gingival margin misalignment is a frequent finding in patients. The most common cause is altered passive eruption; however, in the case presented here, the esthetics of the smile is compromised also due to an inadequate implant placement and crown fabrication.
Case Presentation: This case presented a combination of altered passive eruption and a buccally as well as deeply placed implant crown (#10) that led to disproportionate dimensions of an upper lateral incisor.
Objective: Using a mouse osteoporotic model, this study aimed to determine the influence of hydrophilic titanium surfaces on gene expression and bone formation during the osseointegration process.
Background: Based on the previous evidence, it is plausible to assume that osteoporotic bone has a different potential of bone healing. Therefore, implant surface modification study that aims at enhancing bone formation to further improve short- and long-term clinical outcomes in osteoporosis is necessary.
J Dairy Res
August 2020
The study described in this Research Communication investigated the genotypic and phenotypic profiles of resistance to beta-lactams and other antimicrobials in non-aureus Staphylococci (NAS) isolated from buffalo, goat and sheep mastitis in the Northeast region of Brazil. A total of 190 isolates were analyzed and 42.3, 43.
View Article and Find Full Text PDFThe traditional protocol for guided surgery in a completely edentulous patient is time-consuming, requiring the fabrication of a radiographic guide and a dual cone beam computed tomography (CBCT) scan. Using intraoral scanners to scan the edentulous ridge and the existing denture has been advocated to simplify the process. This technique offers a versatile, precise, and predictable method for the digital planning workflow in edentulous patients for either a fixed or removable restoration.
View Article and Find Full Text PDFStatement Of Problem: Intraoral scanners (IOSs) have some inherent distortions caused by optical and/or software imperfections. However, how other factors such as operator experience, scan time, scanner type, and scan size influence scan accuracy is not clear.
Purpose: The purpose of this in vitro study was to evaluate the trueness and precision of scans performed by 3 professionals with different levels of experience by using 2 IOSs.
Objective: The aim of this split-mouth, triple-blind, randomized clinical trial was to evaluate the long-term clinical efficacy of experimental potassium oxalate concentration (10%) in relieving dentin hypersensitivity (DH), after a four-session application protocol.
Methods: Potassium oxalate gels with different concentrations (5 and 10%) were randomly assigned to half of the 31 patients from the sample in a split-mouth design. The desensitizers were applied following a four-session protocol, one session every 48 h.
A single-blind randomized clinical trial was conducted to evaluate the effectiveness of desensitizing agents with different action mechanisms in reducing cervical dentin hypersensitivity (CDH) after four application sessions, with 24-week follow-up. Sixty patients with CDH were selected in the study and were allocated in three groups of treatment: Desensibilize KF 2%, Clinpro XT Varnish, and Photon Lase III (100 mW, 4 J/cm-1 J/cm each point, 10 sec per point with wavelength of 808 nm). There were four application sessions performed, with a 48-h interval between each one.
View Article and Find Full Text PDFPurpose: To evaluate the visual function and architecture of the central and peripapillary retina in patients with inactive toxoplasmic retinochoroiditis outside the macular and peripapillary regions (zones 2 and 3).
Methods: Cross-sectional study of 20 eyes (18 patients) with zone 2 and 3 toxoplasmic scars and visual acuity ≥20/25. Patients underwent Humphrey 10-2 perimetry, contrast sensitivity (Mars test), and color vision testing (L'Anthony desaturated D-15).
Purpose: To analyze the clinical and epidemiological characteristics of patients with uveitis in an emergency eye care center.
Methods: We conducted a prospective, observational study of patients with active uveitis admitted between May 2012 and July 2012 to an emergency eye care center.
Results: The majority of patients were male (63.