Publications by authors named "Guilherme E P Henriques"

Objective: The present study compared three models of induction of osteoarthritis (OA) and rheumatoid arthritis (RA) in the temporomandibular joint (TMJ) of rats.

Design: The induction method was by injection of complete Freund's adjuvant (CFA) + type II bovine collagen (CII). Twenty-four adult male rats were divided into four groups (n = 6): G1: Sham, 50 μL of 0.

View Article and Find Full Text PDF

The aim of this study was to evaluate 3 transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing 2 implant analogs simulating a clinical situation of 3-unit implant-supported fixed prostheses according to the following transfer impression techniques: group A, squared transfers splinted with dental floss and acrylic resin, sectioned, and re-splinted; group B, squared transfers splinted with dental floss and bis-acrylic resin; and group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast.

View Article and Find Full Text PDF

This study evaluated the effects of axial and oblique occlusal loading on implant-supported partial dentures with different connection systems (external hexagon, internal hexagon, and Morse taper). Upon axial loading, all systems presented similar stress values. Stress values increased under oblique loading.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the effects of adhesive primer applications on the bond strength of resin cements to cast titanium. Four adhesive primers - Metaltite, Metal Primer II, Alloy Primer and Ceramic Primer - and their respective resin cements - Bistite II DC, Link Max, Panavia F 2.0, RelyX Unicem and RelyX ARC - were tested.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the influence of the casting procedure and cyclic loading of prosthetic frameworks on detorque of prosthetic screws and marginal misfit of single unit implant-supported prostheses.

Materials And Methods: Twenty specimens were obtained, each one consisting of a set of an implant (external hexagon 3.75 × 13 mm - Branemark type), a prosthetic abutment (entirely calcinable or overcasted UCLA) and a prosthetic screw.

View Article and Find Full Text PDF

The aim of this study was to evaluate the precision of three different mold filling techniques in order to obtain a cast simulating a three-unit, implant-retained, fixed prosthesis. Thirty casts (n = 10) were obtained using three different mold filling techniques. Group 1 used a unique fulfillment technique, Group 2 used a two-step fulfillment technique, and Group 3 used a latex cylinder technique.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate the distribution of generated stress around implants and adjacent bone tissue using different implant-retained overdenture designs through photoelastic analysis.

Methods: Over an edentulous human mandible, achieved from a human model, 2 or 4 microunit analog abutments were embedded (Master; Conexao Systems Prosthodontics, São Paulo, Brazil), settled in the interforaminal region. Three models of photoelastic resin (Araltec Chemicals Ltda, Hunstman, Guarulhos, São Paulo, Brazil), with 2 or 4 incorporated implants and microunit abutments, were obtained from molds using silicone for duplication.

View Article and Find Full Text PDF

Objective: This study verified the surface microroughness of denture acrylic resins submitted to toothbrushing, chemical disinfection and thermocycling procedures.

Material And Methods: Samples were prepared according to conventional, microwaved and boiled resins and submitted to microroughness measurements before and after procedures using a profilometer (Ra). Data were subjected to anova and Tukey's test (5%).

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the effect of different accelerated aging times on permanent deformation and tensile bond strength of two soft chairside liners, acrylic resin (T) and silicone (MS) based.

Materials And Methods: Different specimens were made for each test of each reliner. The specimens (n = 10) were submitted to accelerated aging for 2, 4, 8, 16, 32, and 64 cycles.

View Article and Find Full Text PDF

Background:   Titanium frameworks are frequently indicated for implant supported prostheses; however, voids are usually encountered inside cast titanium.

Objective:   This study aimed to confirm the efficacy of a radiographic technique for inspection of porosity in commercially pure titanium castings with different diameter.

Materials And Methods:   Sixty dumbbell rods (n=20) with a central 1.

View Article and Find Full Text PDF

Objectives: This study evaluated the influence of prosthetic screw material on joint stability in implantsupported dentures at two levels of fit.

Methods: Ten mandibular implant-supported dentures were fabricated. Twenty cast models were fabricated using these dentures.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate the effect of flask-closure methods, post-pressing times and acrylic resins on denture base adaptation.

Materials And Methods: The resins were flasked using a hydraulic press and closed with the traditional clamp or RS system. Conventional heat-cure resin was polymerised immediately or at 6 h post-pressing at 74 degrees C for 9 h.

View Article and Find Full Text PDF

Statement Of Problem: Implant-retained overdentures are a treatment option for patients who are not satisfied with conventional complete dentures. Although implant-retained overdentures are widely used, little data are available or provided by implant manufacturers about retentive strength and wear of attachments.

Purpose: The purpose of this study was to evaluate retentive strength and fatigue resistance of 4 overdenture bar-and-clip attachment systems.

View Article and Find Full Text PDF

Purpose: This study investigated the effect of in vitro accelerated aging reproduced with thermocycling on the bond strength of three commercially available permanent denture soft liners (PermaSoft, Dentuflex, Ufi-gel) with one heat-polymerized polymethyl methacrylate resin denture base (QC-20) by tensile test.

Material And Methods: Ten specimens were prepared for control and test groups of each material for a total of 60 specimens. All controls were stored in water (37 degrees C) for 24 hours before testing.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the effects of aging on resilient denture liners. The aging effects were produced by using thermal cycling and mechanical brushing and were quantified as changes to surface hardness and roughness of resilient denture liners.

Material And Methods: A plasticized acrylic resin (Dentuflex) and two silicone-based (Molloplast-B, Sofreliner MS) resilient denture liners were examined.

View Article and Find Full Text PDF

Purpose: This study evaluated the abrasion resistance of acrylic resin to routine dental brushing procedures using different dentifrices after the resin surface had been chemically or mechanically polished.

Materials And Methods: Eighty specimens were prepared using heat-polymerizing (HP) and autopolymerizing (AP) acrylic resin, and immediately submitted to grinding with abrasive stones and disks. The specimens were divided into two groups: the first group was mechanically polished (MP) using pumice slurry, and the second group was chemically polished (CP) using heated monomer.

View Article and Find Full Text PDF

Purpose: To evaluate the Knoop hardness (KHN) of the resin cement Enforce activated by chemical/physical mode or physical mode solely; light-cured directly or through a 1.5 mm thick ceramic disc (HeraCeram) on shade DD2.

Materials And Methods: Light-curing was carried out using a conventional quartz tungsten halogen light (QTH) (XL2500) for 40 seconds at 700 mW/cm(2); light-emitting diodes (LED) (Ultrablue Is) for 40 seconds at 440 mW/cm(2); and Xenon plasma arc (PAC) (Apollo 95E) for 3 seconds at 1600 mW/cm(2).

View Article and Find Full Text PDF

Purpose: The purpose of this study was to test the effect of brushing on surface roughness of two resilient liners (Luci Sof and Sofreliner) compared with an acrylic resin (QC 20).

Materials And Methods: Twenty specimens of each material were prepared (25 mm x 14 mm x 3 mm). Ten specimens served as controls and were stored in distilled water and not brushed.

View Article and Find Full Text PDF

Statement Of Problem: Denture microwave disinfection may result in dimensional changes that may distort the acrylic resin base, causing discomfort to the patient.

Purpose: The purpose of this study was to determine the effect of simulated microwave disinfection on maxillary denture base adaptation using 2 different flask closure methods.

Material And Methods: Forty stone cast-wax base sets were prepared for flasking by the traditional flask closure (TFC) and Restriction System flask closure (RSFC) methods (n=20).

View Article and Find Full Text PDF

Objectives: Titanium-ceramic restorations are currently used, despite the pending problem of titanium-ceramic bonding, which has only been partially solved. The surface treatment of the metal proposed by the manufacturer promotes lower bond strength between titanium and porcelain when compared to the conventional metal-ceramic systems. The objective of this study was to evaluate the influence of acid and caustic baths on the bonding characteristics of specific titanium porcelain bonded to cast commercially pure titanium (CP Ti).

View Article and Find Full Text PDF

The purpose of this study was to evaluate the effect of heat treatments on the Vickers hardness of commercially pure titanium and Ti-6Al-4V cast alloys. Six-millimeter-diameter cylindrical specimens were cast in a Rematitan System. Commercially pure titanium and Ti-6Al-4V alloy specimens were randomly assigned to 3 groups (n=10) that received the following heat treatments: control (no heat treatment); treatment 1 (T1): heating at 750 degrees C for 2 h; and treatment 2 (T2): annealing at 955 degrees C for 1 h and aging at 620 degrees C for 2 h.

View Article and Find Full Text PDF

Purpose: Difficulty in cleaning resilient denture liners remains a material disadvantage. The purpose of the present study was to evaluate the effect of denture cleansers on hardness of resilient liner materials.

Materials And Methods: Three resilient liners, Luci Sof (Dentsply), Molloplast-B (Dentax), and Sofreliner (Tokuyama), and two denture cleansers, Efferdent (Warner-Lamber), and 0.

View Article and Find Full Text PDF

Statement Of Problem: Soldering has been suggested to achieve acceptable fit of multi-unit fixed partial denture (FPD) frameworks of 3 or more elements. However, distortion of the entire framework may occur.

Purpose: The purpose of this study was to evaluate marginal fit in 1-piece-casting FPD frameworks comparing 2 casting techniques: the conventional technique (CT) and the over-refractory technique (ORT).

View Article and Find Full Text PDF

Objectives: The aim of this study was to evaluate the tensile bond strength of dual curing luting resin cements to commercially pure titanium at 10 min and 24h after removal of the oxide layer.

Methods: One hundred and twenty titanium discs were obtained by casting and polishing with silicon carbide papers. The titanium discs were sandblasted with 50 microm aluminum oxide, ultrasonic cleaned and bonded in pairs with the resin-based cements Panavia F and Rely X ARC at 10 min and 24h after the sandblasting.

View Article and Find Full Text PDF

Commercially pure titanium (CP Ti) has been widely applied to fabricate cast devices because of its favorable properties. However, the mold temperature recommended for the manufacture of casts has been considered relatively low, causing inadequate castability and poor marginal fit of cast crowns. This study evaluated and compared the influence of mold temperature (430 degrees C--as control, 550 degrees C, 670 degrees C) on the marginal discrepancies of cast CP Ti crowns.

View Article and Find Full Text PDF