Publications by authors named "Guilhem Collier"

Article Synopsis
  • The study aimed to evaluate the regional amplitude and phase of dissolved Xe red blood cell signal oscillations in lung blood vessels using a new imaging technique and contrast it with older methods that ignore phase differences.
  • Researchers used a 3D imaging method on 37 participants (including healthy individuals and patients with pulmonary issues) to analyze these oscillations, applying a novel keyhole reconstruction technique to correct for phase differences.
  • Results indicated varying degrees of phase differences among different groups, with improved consistency in oscillation amplitude measurements when adjusted for phase, suggesting potential insights into blood flow dynamics in the lungs.*
View Article and Find Full Text PDF

Purpose: Three-dimensional hyperpolarized Xe gas exchange imaging suffers from low SNR and long breath-holds, which could be improved using compressed sensing (CS). The purpose of this work was to assess whether gas exchange ratio maps are quantitatively preserved in CS-accelerated dissolved-phase Xe imaging and to investigate the feasibility of CS-dissolved Xe imaging with reduced-cost natural abundance (NA) xenon.

Methods: Xe gas exchange imaging was performed at 1.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility and utility of a deep learning (DL)-based reconstruction for improving the SNR of hyperpolarized Xe lung ventilation MRI.

Methods: Xe lung ventilation MRI data acquired from patients with asthma and/or chronic obstructive pulmonary disease (COPD) were retrospectively reconstructed with a commercial DL reconstruction pipeline at five different denoising levels. Quantitative imaging metrics of lung ventilation including ventilation defect percentage (VDP) and ventilation heterogeneity index (VH) were compared between each set of DL-reconstructed images and alternative denoising strategies including: filtering, total variation denoising and higher-order singular value decomposition.

View Article and Find Full Text PDF

Purpose: To characterize the dependence of Xe-MRI gas transfer metrics upon age, sex, and lung volume in a group of healthy volunteers.

Methods: Sixty-five subjects with no history of chronic lung disease were assessed with Xe-MRI using a four-echo 3D radial spectroscopic imaging sequence and a dose of xenon titrated according to subject height that was inhaled from a lung volume of functional residual capacity (FRC). Imaging was repeated in 34 subjects at total lung capacity (TLC).

View Article and Find Full Text PDF

Commercial human MR scanners are optimised for proton imaging, containing sophisticated prescan algorithms with setting parameters such as RF transmit gain and power. These are not optimal for X-nuclear application and are challenging to apply to hyperpolarised experiments, where the non-renewable magnetisation signal changes during the experiment. We hypothesised that, despite the complex and inherently nonlinear electrodynamic physics underlying coil loading and spatial variation, simple linear regression would be sufficient to accurately predict X-nuclear transmit gain based on concomitantly acquired data from the proton body coil.

View Article and Find Full Text PDF

Background: Hyperpolarised 129-xenon (Xe) magnetic resonance imaging (MRI) shows promise in monitoring the progression of idiopathic pulmonary fibrosis (IPF) due to the lack of ionising radiation and the ability to quantify functional impairment. Diffusion-weighted (DW)-MRI with hyperpolarised gases can provide information about lung microstructure. The aims were to compare Xe DW-MRI measurements with pulmonary function tests (PFTs), and to assess whether they can detect early signs of disease progression in patients with newly diagnosed IPF.

View Article and Find Full Text PDF

The respiratory consequences of acute COVID-19 infection and related symptoms tend to resolve 4 weeks post-infection. However, for some patients, new, recurrent, or persisting symptoms remain beyond the acute phase and persist for months, post-infection. The symptoms that remain have been referred to as long-COVID.

View Article and Find Full Text PDF

Functional lung imaging modalities such as hyperpolarized gas MRI ventilation enable visualization and quantification of regional lung ventilation; however, these techniques require specialized equipment and exogenous contrast, limiting clinical adoption. Physiologically-informed techniques to map proton (H)-MRI ventilation have been proposed. These approaches have demonstrated moderate correlation with hyperpolarized gas MRI.

View Article and Find Full Text PDF

Background: Microvascular abnormalities and impaired gas transfer have been observed in patients with COVID-19. The progression of pulmonary changes in these patients remains unclear.

Research Question: Do patients hospitalized with COVID-19 without evidence of architectural distortion on structural imaging exhibit longitudinal improvements in lung function measured by using H and Xe MRI between 6 and 52 weeks following hospitalization?

Study Design And Methods: Patients who were hospitalized with COVID-19 pneumonia underwent a pulmonary H and Xe MRI protocol at 6, 12, 25, and 51 weeks following hospital admission in a prospective cohort study between November 2020 and February 2022.

View Article and Find Full Text PDF

Background: Hyperpolarized gas MRI is a functional lung imaging modality capable of visualizing regional lung ventilation with exceptional detail within a single breath. However, this modality requires specialized equipment and exogenous contrast, which limits widespread clinical adoption. CT ventilation imaging employs various metrics to model regional ventilation from non-contrast CT scans acquired at multiple inflation levels and has demonstrated moderate spatial correlation with hyperpolarized gas MRI.

View Article and Find Full Text PDF

Background: Recently, deep learning via convolutional neural networks (CNNs) has largely superseded conventional methods for proton ( H)-MRI lung segmentation. However, previous deep learning studies have utilized single-center data and limited acquisition parameters.

Purpose: Develop a generalizable CNN for lung segmentation in H-MRI, robust to pathology, acquisition protocol, vendor, and center.

View Article and Find Full Text PDF

Purpose: Imaging of the different resonances of hyperpolarized Xe in the brain and lungs was performed using a 3D sampling density-weighted MRSI technique in healthy volunteers.

Methods: Four volunteers underwent dissolved-phase hyperpolarized Xe imaging in the lung with the MRSI technique, which was designed to improve the point-spread function while preserving SNR (1799 phase-encoding steps, 14-s breath hold, 2.1-cm isotropic resolution).

View Article and Find Full Text PDF

Shared symptoms and genetic architecture between coronavirus disease (COVID-19) and lung fibrosis suggest severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection may lead to progressive lung damage. The UK Interstitial Lung Disease Consortium (UKILD) post-COVID-19 study interim analysis was planned to estimate the prevalence of residual lung abnormalities in people hospitalized with COVID-19 on the basis of risk strata. The PHOSP-COVID-19 (Post-Hospitalization COVID-19) study was used to capture routine and research follow-up within 240 days from discharge.

View Article and Find Full Text PDF

Background: Hyperpolarized gas MRI can quantify regional lung ventilation via biomarkers, including the ventilation defect percentage (VDP). VDP is computed from segmentations derived from spatially co-registered functional hyperpolarized gas and structural proton ( H)-MRI. Although acquired at similar lung inflation levels, they are frequently misaligned, requiring a lung cavity estimation (LCE).

View Article and Find Full Text PDF

Background: Free-breathing H ventilation MRI shows promise but only single-center validation has yet been performed against methods which directly image lung ventilation in patients with cystic fibrosis (CF).

Purpose: To investigate the relationship between Xe and H ventilation images using data acquired at two centers.

Study Type: Sequence comparison.

View Article and Find Full Text PDF

Preterm birth is associated with low lung function in childhood, but little is known about the lung microstructure in childhood. We assessed the differential associations between the historical diagnosis of bronchopulmonary dysplasia (BPD) and current lung function phenotypes on lung ventilation and microstructure in preterm-born children using hyperpolarized Xe ventilation and diffusion-weighted magnetic resonance imaging (MRI) and multiple-breath washout (MBW). Data were available from 63 children (aged 9-13 yr), including 44 born preterm (⩽34 weeks' gestation) and 19 term-born control subjects (⩾37 weeks' gestation).

View Article and Find Full Text PDF

Respiratory diseases are leading causes of mortality and morbidity worldwide. Pulmonary imaging is an essential component of the diagnosis, treatment planning, monitoring, and treatment assessment of respiratory diseases. Insights into numerous pulmonary pathologies can be gleaned from functional lung MRI techniques.

View Article and Find Full Text PDF

Background Post-COVID-19 condition encompasses symptoms following COVID-19 infection that linger at least 4 weeks after the end of active infection. Symptoms are wide ranging, but breathlessness is common. Purpose To determine if the previously described lung abnormalities seen on hyperpolarized (HP) pulmonary xenon 129 (Xe) MRI scans in participants with post-COVID-19 condition who were hospitalized are also present in participants with post-COVID-19 condition who were not hospitalized.

View Article and Find Full Text PDF

Background: Indices of ventilation heterogeneity (VH) from multiple breath washout (MBW) have been shown to correlate well with VH indices derived from hyperpolarised gas ventilation MRI. Here we report the prediction of ventilation distributions from MBW data using a mathematical model, and the comparison of these predictions with imaging data.

Methods: We developed computer simulations of the ventilation distribution in the lungs to model MBW measurement with 3 parameters: σ determining the extent of VH; V, the lung volume; and V, the dead-space volume.

View Article and Find Full Text PDF

Objectives: Design and build a portable xenon-129 (Xe) hyperpolariser for clinically accessible Xe lung MRI.

Methods: The polariser system consists of six main functional components: (i) a laser diode array and optics; (ii) a B coil assembly; (iii) an oven containing an optical cell; (iv) NMR and optical spectrometers; (v) a gas-handling manifold; and (vi) a cryostat within a permanent magnet. All components run without external utilities such as compressed air or three-phase electricity, and require just three mains sockets for operation.

View Article and Find Full Text PDF

Background: Hyperpolarised gas magnetic resonance imaging (MRI) can be used to assess ventilation patterns. Previous studies have shown the image-derived metric of ventilation defect per cent (VDP) to correlate with forced expiratory volume in 1 s (FEV)/forced vital capacity (FVC) and FEV in asthma.

Objectives: The aim of this study was to explore the utility of hyperpolarised xenon-129 (Xe) ventilation MRI in clinical care and examine its relationship with spirometry and other clinical metrics in people seen in a severe asthma service.

View Article and Find Full Text PDF

Introduction: The COVID-19 pandemic has led to over 100 million cases worldwide. The UK has had over 4 million cases, 400 000 hospital admissions and 100 000 deaths. Many patients with COVID-19 suffer long-term symptoms, predominantly breathlessness and fatigue whether hospitalised or not.

View Article and Find Full Text PDF

Hyperpolarized (HP) Xe MRI uniquely images pulmonary ventilation, gas exchange, and terminal airway morphology rapidly and safely, providing novel information not possible using conventional imaging modalities or pulmonary function tests. As such, there is mounting interest in expanding the use of biomarkers derived from HP Xe MRI as outcome measures in multi-site clinical trials across a range of pulmonary disorders. Until recently, HP Xe MRI techniques have been developed largely independently at a limited number of academic centers, without harmonizing acquisition strategies.

View Article and Find Full Text PDF