Publications by authors named "Guijie Zhu"

The nanoparticle (NP) protein corona significantly influences the outcome of nanomedicine. We present the first example of top-down proteomics (TDP) measurement of the protein corona using capillary isoelectric focusing-mass spectrometry, identifying seventy proteoforms of 16 cancer-related genes. This technique has the potential to revolutionize our understanding of the protein corona and advance nanomedicine.

View Article and Find Full Text PDF

Conventional mass spectrometry (MS)-based bottom-up proteomics (BUP) analysis of the protein corona [i.e., an evolving layer of biomolecules, mostly proteins, formed on the surface of nanoparticles (NPs) during their interactions with biomolecular fluids] enabled the nanomedicine community to partly identify the biological identity of NPs.

View Article and Find Full Text PDF

The wide Mg alloy sheets produced by hot extrusion usually can easily form an inhomogeneous texture, resulting in anisotropic mechanical properties and poor formability. However, few studies have been carried out on the bulk texture investigation at different areas of as-extruded Mg alloy sheets, especially the Mg alloys with different alloying elements. In this work, the effect of Al on the bulk texture and mechanical properties at different areas for three wide Mg-Al-Zn alloy sheets with different Al contents (Mg-3Al-0.

View Article and Find Full Text PDF

Recently, many methods based on hand-designed convolutional neural networks (CNNs) have achieved promising results in automatic retinal vessel segmentation. However, these CNNs remain constrained in capturing retinal vessels in complex fundus images. To improve their segmentation performance, these CNNs tend to have many parameters, which may lead to overfitting and high computational complexity.

View Article and Find Full Text PDF

Glycoproteomic analysis requires efficient separation and sensitive detection to enable the comprehensive characterization of glycan heterogeneity. Here, we report the use of capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) with an electrokinetically-pumped nanospray interface for the study of protein glycosylation microheterogeneity. A fast separation was developed that resolved intact glycopeptides generated from standard proteins within ~9min.

View Article and Find Full Text PDF

Vertically aligned CdTe nanorods (NRs) arrays are successfully grown by a simple one-step and template-free electrodeposition method, and then embedded in the CdS window layer to form a novel three-dimensional (3D) heterostructure on flexible substrates. The parameters of electrodeposition such as deposition potential and pH of the solution are varied to analyze their important role in the formation of high quality CdTe NRs arrays. The photovoltaic conversion efficiency of the solar cell based on the 3D heterojunction structure is studied in detail.

View Article and Find Full Text PDF

High-density CdTe nanorod arrays are successfully embedded in a uniform and compact CdS layer, forming a novel three-dimensional (3D) CdTe NRs/CdS heterojunction structure. The CdS layer is prepared by homogeneous precipitation (HP) method using decomposition of urea. The effects of temperature and concentration of reactants on the growth and composition of CdS film are investigated in detail.

View Article and Find Full Text PDF

We report a capillary isoelectric focusing system based on a sequential injection method for simplified chemical mobilization. This system was coupled to an ion trap mass spectrometer with an electrokinetically pumped nanoelectrospray interface. The nanoelectrospray emitter employed an acidic sheath electrolyte.

View Article and Find Full Text PDF

A tryptic digest generated from Xenopus laevis fertilized embryos was fractionated by RPLC. One set of 30 fractions was analyzed by 100-min CZE-ESI-MS/MS separations (50 h total instrument time), and a second set of 15 fractions was analyzed by 3-h UPLC-ESI-MS/MS separations (45 h total instrument time). CZE-MS/MS produced 70% as many protein IDs (4134 versus 5787) and 60% as many peptide IDs (22 535 versus 36 848) as UPLC-MS/MS with similar instrument time (50 h versus 45 h) but with 50 times smaller total consumed sample amount (1.

View Article and Find Full Text PDF

We used reversed-phase liquid chromatography to separate the yeast proteome into 23 fractions. These fractions were then analyzed using capillary zone electrophoresis (CZE) coupled to a Q-Exactive HF mass spectrometer using an electrokinetically pumped sheath flow interface. The parameters of the mass spectrometer were first optimized for top-down proteomics using a mixture of seven model proteins; we observed that intact protein mode with a trapping pressure of 0.

View Article and Find Full Text PDF

Capillary zone electrophoresis (CZE)-electrospray ionization (ESI)-mass spectrometry (MS) is an interesting complimentary technique to reversed phase liquid chromatography (RPLC)-ESI-MS for proteomics research. However, the low sample loading capacity of CZE (typically a few nL) can limit its application for large-scale proteomics. A number of on-line sample preconcentration methods have been developed to increase sample loading volumes.

View Article and Find Full Text PDF

Single cell analysis is required to understand cellular heterogeneity in biological systems. We propose that single cells (blastomeres) isolated from early stage invertebrate, amphibian, or fish embryos are ideal model systems for the development of technologies for single cell analysis. For these embryos, although cell cleavage is not exactly symmetric, the content per blastomere decreases roughly by half with each cell division, creating a geometric progression in cellular content.

View Article and Find Full Text PDF

We employed UPLC-MS/MS with iTRAQ 8-plex labeling to quantitatively analyze the supernatant produced by two Chinese hamster ovary (CHO) cell lines (CHO K1SV and CHO CAT-S). In each case, the supernatant from the host and three transfected clones were analyzed at days 5, 7, and 10 of culture. A total of eight iTRAQ 8-plex experiments were performed.

View Article and Find Full Text PDF

Proteomic analysis using capillary zone electrophoresis (CZE) typically is performed with linear polyacrylamide (LPA) coated capillaries. These capillaries both minimize the adsorption of peptides and proteins to the inner wall of the capillary and decrease electroosmosis, which increases the separation capacity. LPA coating protocols were first reported by Hjerten in 1985.

View Article and Find Full Text PDF

A sulfonate-silica hybrid strong cation exchange monolith microreactor was synthesized and coupled to a linear polyacrylamide coated capillary for online sample preparation and capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) bottom-up proteomic analysis. The protein sample was loaded onto the microreactor in an acidic buffer. After online reduction, alkylation, and digestion with trypsin, the digests were eluted with 200 mM ammonium bicarbonate at pH 8.

View Article and Find Full Text PDF

We have evaluated CZE-ESI-MS/MS for detection of trace amounts of host cell protein impurities in recombinant therapeutics. Compared to previously published procedures, we have optimized the buffer pH used in the formation of a pH junction to increase injection volume. We also prepared a 5-point calibration curve by spiking 12 standard proteins into a solution of a human mAb.

View Article and Find Full Text PDF

Capillary zone electrophoresis (CZE) is emerging as a useful tool in proteomic analysis. Interest arises from dramatic improvements in performance that result from improvements in the background electrolyte used for the separation, the incorporation of advanced sample injection methods, the development of robust and sensitive electrospray interfaces, and the coupling with Orbitrap mass spectrometers with high resolution and sensitivity. The combination of these technologies produces performance that is rapidly approaching the performance of UPLC-based methods for microgram samples and exceeds the performance of UPLC-based methods for mid- to low nanogram samples.

View Article and Find Full Text PDF

Ultraperformance liquid chromatography (UPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) is typically employed for phosphoproteome analysis. Alternatively, capillary zone electrophoresis (CZE)-ESI-MS/MS has great potential for phosphoproteome analysis due to the significantly different migration times of phosphorylated and unphosphorylated forms of peptides. In this work, we systematically compared UPLC-MS/MS and CZE-MS/MS for phosphorylated peptide identifications (IDs) using an enriched phosphoproteome from the MCF-10A cell line.

View Article and Find Full Text PDF

Top-down proteomics offers the potential for full protein characterization, but many challenges remain for this approach, including efficient protein separations and effective fragmentation of intact proteins. Capillary zone electrophoresis (CZE) has shown great potential for separation of intact proteins, especially for differentially modified proteoforms of the same gene product. To date, however, CZE has been used only with collision-based fragmentation methods.

View Article and Find Full Text PDF

A sulfonate-silica hybrid strong cation-exchange (SCX) monolith was synthesized at the proximal end of a capillary zone electrophoresis column and used for on-line solid-phase extraction (SPE) sample preconcentration. Sample was prepared in an acidic buffer and deposited onto the SCX-SPE monolith and eluted using a basic buffer. Electrophoresis was performed in an acidic buffer.

View Article and Find Full Text PDF

A detachable sulfonate-silica hybrid strong cation-exchange monolith was synthesized in a fused silica capillary, and used for solid phase extraction with online pH gradient elution during capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) proteomic analysis. Tryptic digests were prepared in 50 mM formic acid and loaded onto the strong cation-exchange monolith. Fractions were eluted using a series of buffers with lower concentration but higher pH values than the 50 mM formic acid background electrolyte.

View Article and Find Full Text PDF

We have reported a set of electrokinetically pumped sheath flow nanoelectrospray interfaces to couple capillary zone electrophoresis with mass spectrometry. A separation capillary is threaded through a cross into a glass emitter. A side arm provides fluidic contact with a sheath buffer reservoir that is connected to a power supply.

View Article and Find Full Text PDF

Capillary zone electrophoresis (CZE)-tandem mass spectrometry (MS/MS) has recently attracted attention as a tool for shotgun proteomics. However, its performance for this analysis has so far fallen far below that of reversed-phase liquid chromatography (RPLC)-MS/MS. The use of a CZE method with a wide separation window (up to 90 min) and high peak capacity (ca.

View Article and Find Full Text PDF

We coupled capillary zone electrophoresis (CZE) with an ultrasensitive electrokinetically pumped nanospray ionization source for tandem mass spectrometry (MS/MS) analysis of complex proteomes. We first used the system for the parallel reaction monitoring (PRM) analysis of angiotensin II spiked in 0.45mg/mL of bovine serum albumin (BSA) digest.

View Article and Find Full Text PDF