Despite the progressive course of atrial fibrillation (AF), the optimal timing of radiofrequency catheter ablation (RFCA) during disease course is still unknown. We aimed to investigate the impact of early RFCA within a year after AF diagnosis on procedural outcomes. A single-center retrospective study was conducted on symptomatic AF patients ( = 130) referred for RFCA with a 16-month median follow-up.

View Article and Find Full Text PDF

Despite progress in implantation technology and prophylactic measures, infection complications related to cardiac implantable electronic devices (CIED) are still a major concern with negative impacts on patient outcomes and the health system's resources. Infective endocarditis (IE) represents one of the most threatening CIED-related infections associated with high mortality rates and requires prompt diagnosis and management. Transvenous lead extraction (TLE), combined with prolonged antibiotic therapy, has been validated as an effective approach to treat patients with CIED-related IE.

View Article and Find Full Text PDF

The right bundle branch (RBB), due to its endocardial course, is susceptible to traumatic block caused by "bumping" during right-heart catheterization. In the era of cardiac electrophysiology, catheter-induced RBB block (CI-RBBB) has become a common phenomenon observed during electrophysiological studies and catheter ablation procedures. While typically transient, it may persist for the entire procedure time.

View Article and Find Full Text PDF

Catheter ablation (CA) of left atrial tachycardia adjacent to implanted septal closure devices represents a multifaceted challenge. We describe the case of a 57-year-old patient with remote percutaneous closure of atrial septal defect who underwent successful CA of left atrial tachycardia adjacent to the septal device using a transaortic approach and RF energy. Besides the technical difficulties and associated risks, interference between the device and applied RF parameters may limit ablation efficiency.

View Article and Find Full Text PDF

Introduction: Despite numerous ECG algorithms being developed to localize the site of manifest accessory pathways (AP), they often require stepwise multiple-lead analysis with variable accuracy, limitations, and reproducibility. The study aimed to develop a single-lead ECG algorithm incorporating the P-Delta interval (PDI) as an adjunct criterion to discriminate between right and left manifest AP.

Methods: Consecutive WPW patients undergoing electrophysiological study (EPS) were retrospectively recruited and split into a derivation and validation group (1:1 ratio).

View Article and Find Full Text PDF

Background: This study aimed to collect and analyze the literature data regarding Chiari network (CN) and other right atrium (RA) remnants comprising the Eustachian and Thebesian valves (EV, ThV) as a potential entrapment site during different percutaneous cardiac procedures (PCP).

Methods And Results: A systematic search was conducted using Pubmed and Embase databases following the PRISMA guidelines to obtain available data concerning PCP associated with entrapment of inserted materials within CN-EV-ThV. The final analysis included 41 patients who underwent PCP with reported material entrapment within these RA remnants.

View Article and Find Full Text PDF

Introduction: To evaluate the clinical outcomes of oral mexiletine (oMXT) to treat ventricular tachyarrhythmias (VTAs) in the era of implantable cardioverter-defibrillator (ICD) technology.

Evidence Acquisition: A systematic search was conducted using PubMed, Embase and Cochrane databases following the PRISMA guidelines to collect literature data reporting oMXT efficacy and safety outcomes in treating VTAs in ICD recipients.

Evidence Synthesis: Final analysis included four studies accounting for a total of 91 patients with recurrent VTAs treated with oMXT.

View Article and Find Full Text PDF

Aims: Air entrapment (AE) has been reported as a potential cause of early inappropriate shocks (ISs) following subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, but a cause-effect relationship is not always evident. This systematic review aims to analyse this phenomenon concerning implantation techniques, electrogram (EGM) features, radiologic findings, and patient management.

Methods And Results: A systematic search was conducted using PubMed, Embase, and Google Scholar databases following the PRISMA guidelines to obtain all available literature data since 2010 on S-ICD malfunctions possibly due to AE.

View Article and Find Full Text PDF

Purpose: In patients with cancer, the safety of catheter ablation for non-valvular atrial fibrillation (AF) has not been evaluated, yet. The aim of this study was to assess the safety of AF ablation in cancer survivors.

Methods: Consecutively recruited patients undergoing catheter ablation of non-valvular AF at our center between March 2015 and March 2017 were evaluated.

View Article and Find Full Text PDF

More than 2 decades ago, para-Hisian pacing was introduced to assess the pattern of retrograde conduction during electrophysiological studies. Although there is no ideal maneuver for every patient and condition, para-Hisian pacing is a valuable and handy strategy to differentiate between retrograde conduction over the atrioventricular node and the accessory pathways. The dynamic behavior of para-Hisian pacing, in a region with unique anatomical features, can produce various activation patterns and intriguing electrophysiological phenomena.

View Article and Find Full Text PDF

This case concerns a 24-year-old female who developed malignant ventricular tachyarrhythmia a few weeks after pacemaker implantation for complete heart block. Apparently, right ventricular pacing caused significant repolarization abnormalities in both native and paced rhythms with marked QT prolongation and substantial electrical instability. This case highlights other intriguing phenomena in the puzzle of cardiac repolarization and how pacing therapy may alter this complex process providing arrhythmic substrate in vulnerable subjects.

View Article and Find Full Text PDF

Aim: Ectopic atrial tachycardia (EAT) is a common arrhythmia in children, adolescents, and young adults. Radiofrequency (RF) ablation is often considered the treatment of choice in this population. We sought to evaluate the long-term follow-up after RF ablation.

View Article and Find Full Text PDF

The subcutaneous implantable cardioverter defibrillator (S-ICD) is a valuable alternative to the conventional trans-venous ICD (TV-ICD) for the prevention of sudden cardiac death (SCD). Prospective registries showed that the S-ICD is safe and effective in treating ventricular tachyarrhythmias in high-risk patients without pacing indications. While in earlier studies patients implanted with S-ICDs were young and mostly affected by channelopathies, contemporary S-ICD cohorts include patients with severely impaired left ventricular function and significant comorbidities.

View Article and Find Full Text PDF

Junctional and AV nodal reentrant tachycardia share common electrocardiographic features, but they differ in their management and outcomes after catheter ablation. This case concerns a 60-year-old female who presented with recurrent episodes of a relatively slow, regular supraventricular arrhythmia. Electrocardiographic features of the arrhythmia were discordant regarding its underlying mechanism.

View Article and Find Full Text PDF

Objectives: To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD).

Methods: We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted <6 weeks before enrolment or prior to 01/01/2000, with cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG).

View Article and Find Full Text PDF