In a recent field campaign focused on air quality study, aerosol optical properties, particle number concentration, and PM components were monitored in Changzhou, Jiangsu Province, from May 27 to June 27, 2019. An array of instruments were deployed that included scanning mobility particle size spectrometer (SMPS), aethalometer (AE33), cavity attenuation phase shift single albedo monitor (CAPS-ALB), monitor for aerosols and gases in ambient air (MARGA) and RT-4 organic carbon/elemental carbon (OC/EC) carbon analyzer to study the ① changes in chemical composition and optical parameters of the new particles generated during the campaign period. ② comparison of the aerosol extinction coefficient recorded by these instruments and measured value in the reconstruction of IMPROVE (interagency monitoring of protected visual environment) and the calculated coefficient using MIE theory model were carried out.