A wavelet transform assisted laser-induced fluorescence detector with high sensitivity was developed and evaluated. An unconventional microscope objective with a numerical aperture (NA) of 0.5 and a working distance (WD) of 4.
View Article and Find Full Text PDFActa Otolaryngol
October 2024
Intratympanic steroid injection (ISI) for sudden sensorineural hearing loss (SSNHL) is a relatively popular and effective method, but there is no standardized method for intratympanic steroids for the treatment of SSNHL and no consensus on how to deliver steroids to the middle ear. The purpose of this study was to compare 2 means of intratympanic steroid delivery as therapy for SSNHL. A retrospective chart review was performed for the period from November 2018 to October 2022 at our Department of Otorhinolaryngology-Head and Neck Surgery.
View Article and Find Full Text PDFA novel "windmill" three-channel light-emitting diode induced fluorescence detector (LED-IF) was proposed to maximize the excitation efficiency and fluorescence collection efficiency. Compared with the typical collinear arrangement, the fluorescence intensity of the three channels was increased by 7.85, 3.
View Article and Find Full Text PDFObjective: This study aims to analyze the onset of otitis media secretory, the peak period of infection with the Omicron strain of SARS-CoV-2 virus, and the time of transmigration during a pandemic of the Omicron strain. Additionally, the study aims to investigate to study the presence of SARS-CoV-2 virus in the middle ear cavity of patients with otitis media secretory and the survival time through a new method for detecting SARS-CoV-2 virus antigen in middle ear effusion.
Methods: Retrospective comparison of the incidence of otitis media secretory during infection with SARS-CoV-2 virus Omicron strain from December 15, 2022, to January 15, 2023, versus the noninfection period from December 15, 2021, to January 15, 2022.
To study the heterogeneity of target membrane proteins in single cells with cellular integrity, we proposed a simple and low-cost method to obtain the copy number of the membrane proteins. HeLa cells were labeled by FITC affinity bodies specifically targeting HER2 membrane proteins. The immunolabeled HeLa cells were quantified by a laboratory-built laser induced fluorescence detector.
View Article and Find Full Text PDFA 96-well plate UV fluorometer was developed and evaluated. Eight micro fluorescence detectors close to each other were used as detector array for 8 channels. Each detector employed an UV light emitting diode (LED) as light source and a photodiode (PD) with an amplifier circuit as optoelectronic detector.
View Article and Find Full Text PDFA modified miniaturized hydrogen flame ionization detector (m-FID) was developed and evaluated. An integrated nozzle assembly was constructed to solve the gas leakage caused by adhesive crack during repeated high-low temperature processes or vibration. An embedded sealing structure was designed to realize the face sealing, thus improving the sealing stability and reliability of the m-FID.
View Article and Find Full Text PDFObjective: Ulva linza (L.) is a species of green algae widely distributed in China. We aimed to establish a sensitive online analytical method for quantification of endogenous phytohormones in fresh minute seaweed samples.
View Article and Find Full Text PDFHead and neck squamous cell carcinoma (HNSC) is a prevalent and heterogeneous malignancy with poor prognosis and high mortality rates. There is significant evidence of alternative splicing (AS) contributing to tumor development, suggesting its potential in predicting prognosis and therapeutic efficacy. This study aims to establish an AS-based prognostic signature in HNSC patients.
View Article and Find Full Text PDFHigh-power LED induced fluorescence detector (HP-LED-IF) suffers from problems of large noise and poor baseline stability. In this study, a Peltier thermoelectric cooler (PTC) was utilized to stabilize the HP-LED junction temperature of a HP-LED-IF to reduce the baseline noise for the first time. Compared with traditional fan cooling, the signal-to-noise ratio was improved to 3.
View Article and Find Full Text PDFTo study the success of intratympanic gentamicin (ITG) treatment in reducing vertigo attacks in Meniere's disease (MD) and the value of the Halmagyi head thrust test (HTT) in predicting treatment durability. Retrospective cohort study. Tertiary care vestibular clinic.
View Article and Find Full Text PDFA transparent quartz rod (q) placed vertically on top of a non-premixed hydrogen microjet flame in a flame photometric detector (qFPD) was developed and evaluated for sulfur detection. The microjet flame burned around the quartz rod because of Coanda effect, forming an extended downstream flame zone with a relatively low temperature between 550 and 650 °C, which is favorable to the formation of S*. The emission intensity of S* and the signal-to-noise ratio (SNR) of sulfur response were enhanced 2.
View Article and Find Full Text PDFA miniature laser-induced fluorescence (mLIF) detector utilizing a novel spherical dichroic reflector (SDR), an unconventional long working distance high magnification objective, an uncommon broadband emission-matched excitation filter pair, and a silicon-based photodiode detector assembly instead of a photomultiplier tube was developed and evaluated. The detection cell was placed at the spherical center of the SDR instead of the regular focus, yielding a 1.8× signal-to-noise ratio (SNR) improvement.
View Article and Find Full Text PDFMetal-organic frameworks (MOFs) material with high surface area, good chemical stability and multi-functionality, has become an emerging adsorbent for water treatment. A novel kind of quaternary amine anionic-exchange MOFs UiO-66 namely UiO-66-NMe was firstly synthesized for adsorptive removal of a widely used toxic herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) from aqueous solutions. The well-prepared UiO-66-NMe MOFs were fully characterized, and then the main parameters affecting the adsorption process including solution pH, adsorbent dosage and coexisting anions were systematically investigated.
View Article and Find Full Text PDFA novel kind of cationic metal-organic framework(MOF) based mixed-matrix membrane(MMM) namely cationic MOF-MMM was firstly designed and used for simultaneous dispersive membrane extraction(DME) of six phenoxy carboxylic acid(PCA) herbicides from water samples followed by determination using ultrahigh-performance liquid chromatography tandem mass spectrometry. The cationic MOF-MMM was synthesized by soaking the zirconium-based MOFs in a polyvinylidene fluoride(PVDF) solution and further functionalization with quaternary amine groups, viz., UiO-66-NMe MMM.
View Article and Find Full Text PDFA miniaturized and high sensitive dual channel fluorimeter was developed and evaluated. It employed collinear optical arrangement, a 365 nm and a 470 nm light emitting diodes (LEDs) as light sources, two photodiodes (PDs) integrated with pre-amplifiers as optoelectronic detectors, and a 12.5 mm × 12.
View Article and Find Full Text PDFA green sample preparation method based on aqueous extraction followed by dispersive solid phase extraction (d-SPE) with in situ derivatization (ISD) was developed for the determination of aflatoxins (AFs) in traditional Chinese medicines (TCMs). AFs in TCMs were extracted by alkaline aqueous solution and converted to substituted coumaric acids. Then, mixed-mode anion exchange (MAX) sorbent was used to isolate and enrich the substituted coumaric acids.
View Article and Find Full Text PDFIn this work, multilayer zirconia-coated silica (ZrO/SiO-n) microspheres were successfully produced by a straightforward hydrothermal procedure with a low concentration of Zr (5 mM) under low potential of hydrogen (pH) conditions (pH = =2). The obtained ZrO/SiO-n materials exhibited favorable characteristics for high-performance liquid chromatography (HPLC) separation, including high surface area and pore volume, good pore structure, narrow particle size, and pore size distribution. In addition, the zirconia coverage in the mesopores was confirmed by soaking the material in 1 M NaOH solution, with the particles showing strong resistance to the basic solution.
View Article and Find Full Text PDFA flame photometric detector with a silicon photodiode assembly instead of a photomultiplier tube for sulfur detection was developed and evaluated. The photosensitive area of photodiode, the optical design, and band-pass filters, were optimized. It was found that the optimal photosensitive area of the photodiode was 100 (mm), and three focus lenses combined with a broad band-pass filter of 378/52 nm and a QB21 glass yielded the best result.
View Article and Find Full Text PDFWe have developed an ultrasensitive and highly selective method to quantify low copy number intracellular proteins in a single cell using a low-cost laser-induced fluorescence (LIF) detector and a BV605 fluorescent probe. Active caspase3 proteins in cells were labeled by corresponding antibody-BV605 fluorescent binding, and a cell was injected into a 20 cm × 50 μm i.d.
View Article and Find Full Text PDFA rapid dispersive liquid-liquid micro-extraction (DLLME) with in-situ derivatization method for extraction and purification of aflatoxins (AFs) in vegetable oils was developed and evaluated. Oil extract, dichloromethane and trifluoroacetic acid were mixed and injected into water to form a cloudy solution. AFs in the oil were extracted into the numerous liquid droplets (with diameters from a few microns to dozens of microns) of extractant, where derivatization was carried out in situ.
View Article and Find Full Text PDFAn ultrasensitive analysis method for quantification of endogenous brassinosteroids in fresh minute plants was developed based on dispersive matrix solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry. During the dispersive matrix solid-phase extraction, plant samples were first ground with solid sorbent (dispersant) in one microcentrifuge tube and then centrifuged after adding extraction solvent and cleanup materials (another type of sorbent). Three protocols based on dispersive matrix solid-phase extraction were compared and discussed for plant samples with different matrix complexity.
View Article and Find Full Text PDFA novel UV light emitting diode induced fluorescence detector (LED-IF) with HPLC flow cell was designed and evaluated for determination of aflatoxins. Ray tracing method was employed to optimize the design of the optical components (such as reshaping thin lens for light source and fluorescence collection), and optical structure, and the geometry of flow cell. An ordinary UV LED with wavelength of 370 nm and radiant power of 5 mW was used as excitation light source.
View Article and Find Full Text PDF