Publications by authors named "Gualtieri E"

Background: Data on high-flow nasal oxygen after thoracic surgery are limited and confined to the comparison with low-flow oxygen. Different from low-flow oxygen, Venturi masks provide higher gas flow at a predetermined fraction of inspired oxygen (FiO). We conducted a randomized trial to determine whether preemptive high-flow nasal oxygen reduces the incidence of postoperative hypoxemia after lung resection, as compared to Venturi mask oxygen therapy.

View Article and Find Full Text PDF

Background: Uniportal video-assisted thoracoscopic (U-VATS) lobectomy has been becoming the technique of choice in an increasing number of centers. The aim of our study was to review our experience, evaluating the learning curve of U-VATS for lung lobectomy and outcomes.

Methods: The prospectively collected clinical data of 43 consecutive patients, undergone U-VATS lobectomy from June 2016 to September 2017, were reviewed.

View Article and Find Full Text PDF

The low limits of detection afforded by second harmonic generation (SHG) microscopy coupled with image analysis algorithms enabled quantitative modeling of the temperature-dependent crystallization of active pharmaceutical ingredients (APIs) within amorphous solid dispersions (ASDs). ASDs, in which an API is maintained in an amorphous state within a polymer matrix, are finding increasing use to address solubility limitations of small-molecule APIs. Extensive stability testing is typically performed for ASD characterization, the time frame for which is often dictated by the earliest detectable onset of crystal formation.

View Article and Find Full Text PDF

Second harmonic generation (SHG) was integrated with Raman spectroscopy for the analysis of pharmaceutical materials. Particulate formulations of clopidogrel bisulfate were prepared in two crystal forms (Form I and Form II). Image analysis approaches enable automated identification of particles by bright field imaging, followed by classification by SHG.

View Article and Find Full Text PDF

Airways management in thoracic surgery is usually more difficult than in other surgery. We reported a case of a patient who underwent surgery of evacuation of empyema where after a correct insertion of a left double-lumen tube 37 Fr (DLT), one-lung ventilation was not permitted by the high airways pressure. In fact, the hole of bronchial tip was just against the left bronchial wall retracted probably from inflammatory process.

View Article and Find Full Text PDF

Identifying and then optimizing initial crystallization conditions is a prerequisite for macromolecular structure determination by crystallography. Improved technologies enable data collection on crystals that are difficult if not impossible to detect using visible imaging. The application of second-order nonlinear imaging of chiral crystals and ultraviolet two-photon excited fluorescence detection is shown to be applicable in a high-throughput manner to rapidly verify the presence of nanocrystals in crystallization screening conditions.

View Article and Find Full Text PDF

Studies were undertaken to assess the merits and limitations of second-harmonic generation (SHG) for the selective detection of protein and polypeptide crystal formation, focusing on the potential for false positives from SHG-active salts present in crystallization media. The SHG activities of salts commonly used in protein crystallization were measured and quantitatively compared with reference samples. Out of 19 salts investigated, six produced significant background SHG and 15 of the 96 wells of a sparse-matrix screen produced SHG upon solvent evaporation.

View Article and Find Full Text PDF

CrN-Ag nanocomposite coatings are deposited on Si(100) wafers and 20MnCr5 steel disks in a mixed Ar+N2 atmosphere by reactive magnetron sputtering. Structure, composition and morphology were investigated by Scanning Electron Microscopy (SEM), Auger Electron Spectroscopy (AES), X-ray Photoemission Spectroscopy (XPS), X-ray Diffraction (XRD) and Focused Ion Beam (FIB) cross sectional analysis. The as deposited film matrix is mainly composed by CrN phase (78%), but a relevant part (28%) is composed by Cr2N.

View Article and Find Full Text PDF

This experimental work is oriented to give a contribution to the knowledge of the relationship among surface roughness parameters and tribological properties of lubricated surfaces; it is well known that these surface properties are strictly related, but a complete comprehension of such correlations is still far to be reached. For this purpose, a mechanical polishing procedure was optimized in order to induce different, but well controlled, morphologies on Si(100) surfaces. The use of different abrasive papers and slurries enabled the formation of a wide spectrum of topographical irregularities (from the submicro- to the nano-scale) and a broad range of surface profiles.

View Article and Find Full Text PDF

The present paper reports the purification and biochemical characterization of an albumin identified in mature lentil seeds with high sequence similarity to pea PA2. These proteins are found in many edible seeds and are considered potentially detrimental for human health due to the potential allergenicity and lectin-like activity. Thus, the description of their possible presence in food and the assessment of the molecular properties are relevant.

View Article and Find Full Text PDF

It is notoriously difficult to grow membrane protein crystals and solve membrane protein structures. Improved detection and screening of membrane protein crystals are needed. We have shown here that second-order nonlinear optical imaging of chiral crystals based on second harmonic generation can provide sensitive and selective detection of two-dimensional protein crystalline arrays with sufficiently low background to enable crystal detection within the membranes of live cells.

View Article and Find Full Text PDF

Second-order nonlinear optical imaging of chiral crystals (SONICC) is explored for selective detection of integral membrane protein crystals grown in opaque and turbid environments. High turbidity is a hallmark of membrane protein crystallization due to the extensive use of detergent and/or lipids that often form various mesophases. Detection of crystals in such media by conventional optical methods (e.

View Article and Find Full Text PDF

Post-thoracotomy pain is one of the most severe types of postoperative pain. It can last up to 2 months and can become chronic in 30% of patients. Pain relief after thoracic surgery is of particular significance, not only for ethical considerations but also for reduction of postoperative pulmonary and cardiac complications.

View Article and Find Full Text PDF

The unique symmetry properties of second harmonic generation (SHG) microscopy enabled sensitive and selective imaging of protein microcrystals with negligible contributions from solvated proteins or amorphous protein aggregates. In studies of microcrystallites of green fluorescent protein (GFP) prepared in 500 pL droplets, the SHG intensities rivaled those of fluorescence, but with superb selectivity for crystalline regions. GFP in amorphous aggregates and in solution produced substantial background fluorescence, but no detectable SHG.

View Article and Find Full Text PDF

It is unclear whether shorter wave latencies of middle-latency-auditory-evoked-potentials may be associated to cognitive function other than nondeclarative memory. We investigated the presence of declarative, nondeclarative and dreaming memory in propofol-anaesthetized patients and any relationship to intraoperatively registered middle-latency-auditory-evoked-potentials. An audiotape containing one of two stories was presented to patients during anaesthesia.

View Article and Find Full Text PDF

Esophagectomy for carcinoma of the esophagus is associated with significant mortality and morbidity. Patients with esophageal cancer have frequently obstruction with dysphagia and they often develop malnutrition. In addition, patients can suffer from chronic aspiration leading to a poor preoperative respiratory status.

View Article and Find Full Text PDF

Purpose: To develop a novel pulse sequence called spin-locked echo planar imaging (EPI), or (SLEPI), to perform rapid T1rho-weighted MRI.

Materials And Methods: SLEPI images were used to calculate T1rho maps in two healthy volunteers imaged on a 1.5-T Sonata Siemens MRI scanner.

View Article and Find Full Text PDF

Rationale And Objectives: Physiological noise in blood oxygen level-dependent functional magnetic resonance imaging (BOLD fMRI) has been shown to have characteristics similar to the BOLD signal itself, suggesting that it may have a vascular dependence. In this study, we evaluated the influence of physiological noise in fMRI as revealed by the differences in vasculature sensitivity of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI).

Materials And Methods: The contribution of physiological noise to the fMRI signal during activation of the visual cortex was assessed by comparing its temporal characteristics with respect to echo time (TE), using both GE-EPI and SE-EPI.

View Article and Find Full Text PDF

The application of T1 in the rotating frame (T1rho) to functional MRI in humans was studied at 3 T. Increases in neural activity increased parenchymal T1rho. Modeling suggested that cerebral blood volume mediated this increase.

View Article and Find Full Text PDF

The temporal resolving power of blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) at 3T was investigated in the visual and auditory cortices of the human brain. By using controlled temporal delays and selective visual hemifield stimulation, regions with similar (left vs. right occipital cortex) and different (occipital cortex vs.

View Article and Find Full Text PDF

Recent theoretical and experimental work has suggested that spin echo (SE) functional MRI (fMRI) has improved localization of neural activity compared to gradient echo (GE) fMRI at high field strengths, albeit with a decrease in blood oxygenation level-dependent (BOLD) contrast. The present study investigated spatial and temporal variations in GE and SE fMRI at 3 T in response to a brief visual stimulus. The results demonstrate that SE BOLD contrast reaches its maximum amplitude more quickly than does GE contrast at long echo times.

View Article and Find Full Text PDF

Rationale And Objectives: Subject motion is well recognized as a significant impediment to resolution and sensitivity in functional magnetic resonance imaging (fMRI). A parallel confounder to fMRI data quality is geometric image distortion, particularly at high field strengths, due to susceptibility-induced magnetic field inhomogeneity. Consequently, many high-field echo-planar imaging methods incorporate a post-processing distortion correction by acquiring a field map of the sample prior to the fMRI measurement.

View Article and Find Full Text PDF