The US and European guidelines for the diagnosis and management of hypertension recommend the introduction of systematic home and night Blood Pressure (BP) monitoring. Fully-automated wearable devices can address the needs of patients and clinicians by improving comfort while achieving measurement accuracy. Often located at the wrist and based on indirect BP measurements, these devices must address the challenges of ambulatory scenarios.
View Article and Find Full Text PDFObjective: The objective of this study was to compare the systolic (S) and diastolic (D) blood pressure (BP) estimations from a new optical device at the wrist with invasive measurements performed on patients scheduled for radial arterial catheterization in the ICU. Optical signals were automatically processed by a library of algorithms from Aktiia SA (OBPM - optical blood pressure monitoring algorithms).
Methods: A total of 31 participants from both sexes, aged 32-87 years, were enrolled in the study (NCT03837769).
Annu Int Conf IEEE Eng Med Biol Soc
July 2018
The measurement of peripheral oxygen saturation (SpO2) in neonatal intensive care units (NICUs) poses a significant challenge. Motion artifacts due to the patient's limb motion induce many false alarms, which in turn cause an additional workload for the medical staff and anxiety for the parents. We developed a reflectance pulse oximeter dedicated to be placed at the patient's forehead, which is less prone to such artifacts.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2015
In this work, we present an accelerometry-based device for robust running speed estimation integrated into a watch-like device. The estimation is based on inertial data processing, which consists in applying a leg-and-arm dynamic motion model to 3D accelerometer signals. This motion model requires a calibration procedure that can be done either on a known distance or on a constant speed period.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
October 2016
Cooperative sensors is a novel measurement architecture that allows the acquiring of biopotential signals on patients in a comfortable and easy-to-integrate manner. The novel sensors are defined as cooperative in the sense that at least two of them work in concert to measure a target physiological signal, such as a multi-lead electrocardiogram or a thoracic bioimpedance.This paper starts by analysing the state-of-the-art methods to simultaneously measure biopotential and bioimpedance signals, and justifies why currently (1) passive electrodes require the use of shielded or double-shielded cables, and (2) active electrodes require the use of multi-wired cabled technologies, when aiming at high quality physiological measurements.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
December 2013
The clinical demand for a device to monitor blood pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called pulse wave velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides nonocclusive beat-by-beat estimations of mean arterial pressure (MAP) by measuring the pulse transit time (PTT) of arterial pressure pulses travelling from the ascending aorta toward the subcutaneous vasculature of the chest.
View Article and Find Full Text PDF