Publications by authors named "Grigg P"

Tumor progression locus 2 (TPL2; also known as MAP3K8) is a mitogen-activated protein kinase (MAPK) kinase kinase (MAP3K) that phosphorylates the MAPK kinases MEK1 and MEK2 (MEK1/2), which, in turn, activate the MAPKs extracellular signal-regulated kinase 1 (ERK1) and ERK2 (ERK1/2) in macrophages stimulated through the interleukin-1 receptor (IL-1R), Toll-like receptors (TLRs), or the tumor necrosis factor receptor (TNFR). We describe a conserved and critical role for TPL2 in mediating the effector functions of neutrophils through the activation of the p38 MAPK signaling pathway. Gene expression profiling and functional studies of neutrophils and monocytes revealed a MEK1/2-independent branch point downstream of TPL2 in neutrophils.

View Article and Find Full Text PDF

Replication-competent viruses, such as Vaccinia virus (VACV), are powerful tools for the development of oncolytic viral therapies and elicit superior immune responses when used as vaccine and immunotherapeutic vectors. However, severe complications from uncontrolled viral replication can occur, particularly in immunocompromised individuals or in those with other predisposing conditions. VACVs constitutively expressing interferon-γ (IFN-γ) replicate in cell culture indistinguishably from control viruses; however, they replicate in vivo to low or undetectable levels, and are rapidly cleared even in immunodeficient animals.

View Article and Find Full Text PDF

We describe a method for evaluating the threshold for cutaneous mechanical sensation in rodents, based on a stimulator that drives a probe against the plantar surface of the foot. The stimulator applies loads that can be either constant or linearly increased. We describe withdrawal responses, including forms of movement that precede foot withdrawals.

View Article and Find Full Text PDF

Rabbit Achilles tendons (N = 8) were subjected to tensile loading while internal water movements were followed using NMR. The distribution of the internal water in tendons was measured using a one-dimensional proton-density map that was collected along a radial line oriented transverse to the tendon's long axis. The proton density map was created from fits to T2 relaxation data.

View Article and Find Full Text PDF

The level of tissue hydration is known to effect viscoelastic material properties. However, prior studies have not fully investigated the effect of hydration on dynamic behavior nor compared the results of transient and dynamic behavior. The material properties of medial collateral rat knee ligaments were studied in relation to hydration, using (sequentially) 0.

View Article and Find Full Text PDF

Tendons exhibit viscoelastic mechanical behavior under tensile loading. The elasticity arises from the collagen chains that form fibrils, while the viscous response arises from the interaction of the water with the solid matrix. Therefore, an understanding of the behavior of water in response to the application of a load is crucial to the understanding of the origin of the viscous response.

View Article and Find Full Text PDF

The redistribution of water in response to static tensile loading was investigated in rabbit Achilles tendons in vitro. The distribution of water was measured along a radially oriented line, using a one-dimensional proton-density map created from fits to diffusion-weighted magnetic resonance (MR) data. Water movements were measured during application of tensile loads of 5N (N=7) and 10N (N=6).

View Article and Find Full Text PDF

Viscoelastic properties of skin samples were measured in three types of mice (tight skin, Tsk, control and Mov-13), that are known to differ with regard to content of type I collagen. The experimental design used uniaxial stretching and measured the creep response and the complex compliance. The creep response was measured directly.

View Article and Find Full Text PDF

The water apparent diffusion coefficient (ADC) in rabbit Achilles tendon is anisotropic, diffusion-time dependent, and changes as a function of tensile load. Water ADC changes of tendon under mechanical load are thought to be due to the extrusion of water from the more restricted tendon core to a relatively unrestricted bulk phase at the periphery (rim) of the tendon. Tensile loading may influence water ADC values by changing the spatial separation of restricting barriers (e.

View Article and Find Full Text PDF

When skin is stretched, stimuli experienced by a cutaneous mechanoreceptor neuron are transmitted to the nerve ending through the skin. In these experiments, we tested the hypothesis that the viscoelastic response of the skin influences the dynamic response of cutaneous rapidly adapting (RA) neurons. Cutaneous RA afferent neurons were recorded in 3 species of mice (Tsk, Pallid, and C57BL6) whose skin has different viscoelastic properties.

View Article and Find Full Text PDF

Skin develops biaxial stresses and strains when stretched. Rapidly adapting cutaneous mechanoreceptor neurons are known to be stretch sensitive, yet in the past, they have been studied using stretch stimuli applied along only a single direction. In this study, cutaneous rapidly adapting mechanoreceptors were studied in preparations of isolated skin in which the skin was stretched dynamically using biaxial stretch stimuli and in which loads and displacements were measured along two directions.

View Article and Find Full Text PDF

Twenty-five rapidly adapting mechanoreceptor afferents were recorded in an in vitro preparation of rat skin and nerve. Single units were recorded while the skin was subjected to dynamic uniaxial stretch using a pseudo-Gaussian noise (PGN) input waveform. Force was the controlled variable in stretch stimuli.

View Article and Find Full Text PDF

Stochastic resonance (SR) is a phenomenon wherein the response of a nonlinear system to a weak input signal is optimized by the presence of a particular, nonzero level of noise. Our objective was to demonstrate cross-modality SR in human sensory perception. Specifically, we were interested in testing the hypothesis that the ability of an individual to detect a subthreshold mechanical cutaneous stimulus can be significantly enhanced by introducing a particular level of electrical noise.

View Article and Find Full Text PDF

Rapidly adapting (RA), stretch-sensitive neurons were recorded in vitro, using an isolated preparation of skin and nerve from mouse hindlimb. The skin was stretched uniaxially using a pseudo-Gaussian noise stimulus. Loads and displacements were recorded as were spike responses of single RA afferent neurons.

View Article and Find Full Text PDF

The properties of three types of indentation stimulators: filament indenters, a spring gauge indenter, and an electromechanical stimulator, were evaluated by actuating each device against a 3-direction load cell. The on-axis loads produced by filament indenters were independent of the degree of buckling. The off-axis loads produced by a filament increased with the degree of buckling of the filament, and had magnitudes that were up to 25% of the on-axis load.

View Article and Find Full Text PDF

Experiments were done to characterize responses to stretch and to determine what stretch-related mechanical variables are most closely associated with stretch. Cutaneous afferent neurons were recorded using an in vitro preparation of rat hairy skin. SA2 afferents and mechanically sensitive C afferents were studied using static stretch stimuli in which the skin was stretched along different directions.

View Article and Find Full Text PDF

Mechanosensitive nociceptors with unmyelinated axons (C-fibers) were studied in a preparation of isolated skin and nerve from rat. Afferent discharges were recorded while the skin was mechanically stimulated using quantitative stretch (tension) and indentation (compression). The apparatus allowed for generating stimuli of equal magnitudes in both tension and compression.

View Article and Find Full Text PDF

A nonlinear systems identification method was used to develop constitutive equations for soft tissue specimens under uniaxial tension. The constitutive equations are developed from a single test by applying a pseudorandom Gaussian (PGN) stress input to the specimen, measuring the resulting strain, and calculating the Volterra-Wiener kernels. First and second order kernels were developed for two tissues with widely different properties, rat medial collateral knee ligaments, and rat skin.

View Article and Find Full Text PDF

We have investigated variations in the excitability of mammalian cutaneous mechanoreceptor neurons. We focused on the phase dynamics of an action potential relative to a periodic stimulus, showing that the excitability of these sensory neurons has interesting nonstationary oscillations. Using a wavelet analysis, these oscillations were characterized through the depiction of their period as a function of time.

View Article and Find Full Text PDF

Objective: To identify computer facilities available in 3 dental schools where 3 different approaches to the use of technology-based learning material have been adopted and assess dental students' perception of their own computer skills and their attitudes towards information technology.

Design: Multicentre cross sectional by questionnaire.

Subjects: All 181 dental students in their final year of study (1997-8).

View Article and Find Full Text PDF

While it is clear that the TMJ joint has a sensory innervation like other synovial joints, there is little specific information about the function of the innervation of the TMJ. In order to provide a template upon which future studies might build, this article briefly reviews the function of sensory neurons in other synovial joints.

View Article and Find Full Text PDF

Water diffusion measurements were performed on rabbit Achilles tendons during static tensile loading and tendons in an unloaded state. The apparent diffusion coefficient (ADC) was measured along two directions: parallel and perpendicular to the long axis of the tendon. Tendons were studied after being prepared in two ways: (a) after being stored frozen in phosphate-buffered saline (PBS) and (b) freshly isolated.

View Article and Find Full Text PDF

Surveys of final year dental students were conducted in 1996 and 1997 to see if there were any detectable differences in students' perception of their own information technology IT skills and attitudes towards information technology following the opening of a dedicated computer-assisted-learning (CAL) room. An increase was seen in students' confidence levels, with fewer assessing themselves as IT "beginners" (1996 = 36%; 1997 = 14%), and more assessing themselves as competent in some basic skills (52%; 41%). Although more students were found to be using basic computer facilities (word processing, email, the World Wide Web), there was little difference in attitudes towards these packages between the 2 years.

View Article and Find Full Text PDF

A finite element based method to determine the incremental elastic material properties of planar membranes was developed and evaluated. The method is applicable to tissues that exhibit inhomogeneity, geometric and material nonlinearity, and anisotropy. Markers are placed on the tissue to form a four-node quadrilateral element.

View Article and Find Full Text PDF