Carbon-fiber microelectrodes are proven and powerful sensors for electroanalytical measurements in a variety of environments, including complex systems such as the brain. They are used to detect and quantify a range of biological molecules, including neuropeptides, which are of broad interest for understanding physiological function. The enkephalins (met- and leu-) are endogenous opioid peptides that are involved in both pain and motivated behavior.
View Article and Find Full Text PDFEndogenous opioid neuropeptides serve as important chemical signaling molecules in both the central and peripheral nervous systems, but there are few analytical tools for directly monitoring these molecules . The opioid peptides share the amino acid motif, Tyr-Gly-Gly-Phe-, at the N-terminus. Met-enkephalin is a small opioid peptide comprised of only five amino acids with methionine (Met) incorporated at the C-terminus.
View Article and Find Full Text PDFDopamine (DA) signaling is critically important in striatal function, and this metabolically demanding process is fueled largely by glucose. However, DA and glucose are typically studied independently and, as such, the precise relationship between DA release and glucose availability remains unclear. Fast-scan cyclic voltammetry (FSCV) is commonly coupled with carbon-fiber microelectrodes to study DA transients.
View Article and Find Full Text PDFThere is an increasing need for fundamental electrochemistry concepts to be taught in the undergraduate curriculum, given the broad applicability of electrochemical technologies in addressing a wide range of global issues from critical energy shortages to real-time medical diagnostics. However, many electrochemical concepts are often taught in disparate laboratory experiments, spread out through the curriculum, which can be intimidating to students (and instructors). This experiment, which has been tested and optimized in the undergraduate classroom over multiple semesters, covers a wide range of electrochemistry topics in realizing the construction of a hydrogen peroxide (HO) sensor that is based on Prussian blue electrochemistry.
View Article and Find Full Text PDFGlutamate and dopamine (DA) represent two key contributors to striatal functioning, a region of the brain that is essential to motor coordination and motivated behavior. While electroanalytical techniques can be utilized for rapid, spatially resolved detection of DA in the interferent-rich brain environment, glutamate, a nonelectroactive analyte, cannot be directly detected using electroanalytical techniques. However, it can be probed using enzyme-based sensors, which generate an electroactive reporter in the presence of glutamate.
View Article and Find Full Text PDFThe endogenous opioid system is commonly targeted in pain treatment, but the fundamental nature of neuropeptide release remains poorly understood due to a lack of methods for direct detection of specific opioid neuropeptides in situ. These peptides are concentrated in, and released from, large dense-core vesicles in chromaffin cells. Although catecholamine release from these neuroendocrine cells is well characterized, the direct quantification of opioid peptide exocytosis events has not previously been achieved.
View Article and Find Full Text PDFCarbon fiber microelectrodes are commonly used for real-time monitoring of individual exocytosis events at single cells. Since the nature of an electrochemical signal is fundamentally governed by mass transport to the electrode surface, microelectrode geometry can be exploited to achieve precise and accurate measurements. Researchers traditionally pair amperometric measurements of exocytosis with a ∼10-μm diameter, disk microelectrode in an "artificial synapse" configuration to directly monitor individual release events from single cells.
View Article and Find Full Text PDFFor decades, carbon-fiber microelectrodes have been used in amperometric measurements of neurotransmitter release at a wide variety of cell types, providing a tremendous amount of valuable information on the mechanisms involved in dense-core vesicle fusion. The electroactive molecules that are released can be detected at the opposing microelectrode surface, allowing for precise quantification as well as detailed kinetic information on the stages of neurotransmitter release. However, it remains unclear how much of the catecholamine that is released into the artificial synapse escapes detection.
View Article and Find Full Text PDFCarbon-fiber microelectrodes are instrumental tools in neuroscience used for the electroanalysis of neurochemical dynamics and recordings of neural activity. However, performance is variable and dependent on fabrication strategies, the biological response to implantation, and the physical and chemical composition of the recording environment. This presents an analytical challenge, as electrode performance is difficult to quantitatively assess especially when electrodes are permanently implanted or cemented in place.
View Article and Find Full Text PDFCarbon-fiber microelectrodes have proven to be an indispensable tool for monitoring exocytosis events using amperometry. When positioned adjacent to a cell, a traditional microdisc electrode is well suited for quantification of discrete exocytotic release events. However, the size of the electrode does not allow for intracellular electrochemical measurements, and the amperometric approach cannot distinguish between the catecholamines that are released.
View Article and Find Full Text PDFBackground-subtracted fast-scan cyclic voltammetry (FSCV) provides a method for detecting molecular fluctuations with high spatiotemporal resolution in the brain of awake and behaving animals. The rapid scan rates generate large background currents that are subtracted to reveal changes in analyte concentration. Although these background currents are relatively stable, small changes do occur over time.
View Article and Find Full Text PDFRecent studies have described a role for lactate in brain energy metabolism and energy formation, challenging the conventional view that glucose is the principle energy source for brain function. To date, lactate dynamics in the brain are largely unknown, limiting insight into function. We addressed this by developing and characterizing a lactate oxidase-modified carbon-fiber microelectrode coupled with fast-scan cyclic voltammetry.
View Article and Find Full Text PDFElectrochemical monitoring of non-electroactive species requires a biosensor that is stable and selective, with sensitivity to physiological concentrations of targeted analytes. We have combined glucose oxidase-modified carbon-fiber microelectrodes with fast-scan cyclic voltammetry for real-time measurements of glucose fluctuations in brain tissue. Work presented herein quantitatively compares three approaches to enzyme immobilization on the microelectrode surface-physical adsorption, hydrogel entrapment, and entrapment in electrospun nanofibers.
View Article and Find Full Text PDFHydrogen peroxide (HO) is a reactive oxygen species that serves as an important signaling molecule in normal brain function. At the same time, excessive HO concentrations contribute to myriad pathological consequences resulting from oxidative stress. Studies to elucidate the diverse roles that HO plays in complex biological environments have been hindered by the lack of robust methods for probing dynamic HO fluctuations in living systems with molecular specificity.
View Article and Find Full Text PDFThe effects of electrochemical preconditioning of P-55 pitch-based carbon-fiber microelectrodes were quantitatively examined in this study. Microstructural characterization of the electrode surface was done using Raman spectroscopy and scanning electron microscopy. Electrochemical performance was evaluated using cyclic voltammetry.
View Article and Find Full Text PDFBackground-subtracted fast-scan cyclic voltammetry (FSCV) has emerged as a powerful analytical technique for monitoring subsecond molecular fluctuations in live brain tissue. Despite increasing utilization of FSCV, efforts to improve the accuracy of quantification have been limited due to the complexity of the technique and the dynamic recording environment. It is clear that variable electrode performance renders calibration necessary for accurate quantification; however, the nature of in vivo measurements can make conventional postcalibration difficult, or even impossible.
View Article and Find Full Text PDFCerebral blood flow ensures delivery of nutrients, such as glucose, to brain sites with increased metabolic demand. However, little is known about rapid glucose dynamics at discrete locations during neuronal activation in vivo. Acute exposure to many substances of abuse elicits dopamine release and neuronal activation in the striatum; however, the concomitant changes in striatal glucose remain largely unknown.
View Article and Find Full Text PDFBackground: Modern cerebral blood flow (CBF) detection favors the use of either optical technologies that are limited to cortical brain regions, or expensive magnetic resonance. Decades ago, inhalation gas clearance was the choice method of quantifying CBF, but this suffered from poor temporal resolution. Electrolytic H2 clearance (EHC) generates and collects gas in situ at an electrode pair, which improves temporal resolution, but the probe size has prohibited meaningful subcortical use.
View Article and Find Full Text PDFFast-scan cyclic voltammetry (FSCV) has attracted attention for studying in vivo neurotransmission due to its subsecond temporal resolution, selectivity, and sensitivity. Traditional FSCV measurements use background subtraction to isolate changes in the local electrochemical environment, providing detailed information on fluctuations in the concentration of electroactive species. This background subtraction removes information about constant or slowly changing concentrations.
View Article and Find Full Text PDFMethionine-enkephalin (M-ENK) and leucine-enkephalin (L-ENK) are small endogenous opioid peptides that have been implicated in a wide variety of complex physiological functions, including nociception, reward processing, and motivation. However, our understanding of the role that these molecules play in modulating specific brain circuits remains limited, largely due to challenges in determining where, when, and how specific neuropeptides are released in tissue. Background-subtracted fast-scan cyclic voltammetry coupled with carbon-fiber microelectrodes has proven to be sensitive and selective for detecting rapidly fluctuating neurochemicals in vivo; however, many challenges exist for applying this approach to the detection of neuropeptides.
View Article and Find Full Text PDFTechnological advances have allowed background-subtracted fast-scan cyclic voltammetry to emerge as a powerful tool for monitoring molecular fluctuations in living brain tissue; however, there has been little progress to date in advancing electrode calibration procedures. Variability in the performance of these handmade electrodes renders calibration necessary for accurate quantification; however, experimental protocol makes standard postcalibration difficult or in some cases impossible. We have developed a model that utilizes information contained in the background charging current to predict electrode sensitivity to dopamine, ascorbic acid, hydrogen peroxide, and pH shifts at any point in an electrochemical experiment.
View Article and Find Full Text PDFJ Electroanal Chem (Lausanne)
March 2013
The electrochemical detection of neurotransmitters has centered on fast scan cyclic voltammetry (FSCV) due to its temporal resolution, sensitivity and chemical selectivity. FSCV is a differential technique that records phasic (second-to-second) changes in the concentration of electroactive neurotransmitters such as dopamine (DA). To isolate the currents due to fluctuations in analyte concentration, in other words to make these phasic measurements, requires the subtraction of a large background current.
View Article and Find Full Text PDFMethods capable of nondestructively collecting high-quality, real-time chemical information from living human stem cells are of increasing importance given the escalating relevance of stem cells in therapeutic and regenerative medicines. Raman spectroscopy is one such technique that can nondestructively collect real-time chemical information. Living cells uptake gold nanoparticles and transport these particles through an endosomal pathway.
View Article and Find Full Text PDFTransient local pH changes in the brain are important markers of neural activity that can be used to follow metabolic processes that underlie the biological basis of behavior, learning and memory. There are few methods that can measure pH fluctuations with sufficient time resolution in freely moving animals. Previously, fast-scan cyclic voltammetry at carbon-fiber microelectrodes was used for the measurement of such pH transients.
View Article and Find Full Text PDFFast scan cyclic voltammetry (FSCV) has been used previously to detect neurotransmitter release and reuptake in vivo. An advantage that FSCV has over other electrochemical techniques is its ability to distinguish neurotransmitters of interest (i.e.
View Article and Find Full Text PDF