Scleroderma is a chronic and progressive autoimmune disorder of connective tissues often causing lesions and deformities of the hands. Individuals affected by this condition experience daily life limitations and are typically unable to take part in sport activities that involve impacts on the hands. In this article we describe the design and manufacturing of custom-made hand orthoses to play sitting volleyball, for an elite paralympic athlete affected by scleroderma.
View Article and Find Full Text PDFBackground: Despite the demonstrated greater efficacy of microprocessor knees (MPK) over mechanical knees (MK), the latter is still widely used by persons with transfemoral amputation. Besides motivations related to local insurance policies, quality of life (QoL) and satisfaction with the prosthesis play a key role in user preference.
Objective: The aim of this study is to compare QoL and satisfaction in a large sample of MPK and MK users and to assess how these outcomes are explained by clinical and demographic characteristics.
A well-fitting socket and a fine-tuned foot alignment are crucial elements in a running-specific prosthesis to allow Paralympic athletes with below-knee amputation to express their full competitive potential. For this reason, once a satisfactory socket-foot configuration is established after dynamic alignment, it is fundamental to reproduce the same conditions when constructing the definitive carbon fiber socket, and when renewing or constructing a back-up prosthesis, without dismantling the original. In addition, to cope with emerging needs of the athlete, it would be beneficial to implement fine-tuning adjustments of the alignment in a very controlled manner.
View Article and Find Full Text PDFThe design and fitting of prosthetic sockets can significantly affect the acceptance of an artificial limb by persons with lower limb amputations. Clinical fitting is typically an iterative process, which requires patients' feedback and professional assessment. When feedback is unreliable due to the patient's physical or psychological conditions, quantitative measures can support decision-making.
View Article and Find Full Text PDFKnowledge about the mechanical properties of lower-limb prosthetic sockets fabricated with resin infusion lamination and composite materials is limited. Therefore, sockets can be subject to mechanical failure and over-dimensioning, both of which can have severe consequences for patients. For this reason, an exploratory study was conducted to analyze the effect of stratigraphy (layup and fibers), matrix (resin) and mechanical connection (socket distal adapter) on socket static strength, with the objectives of: 1) implementing a mechanical testing system for lower-limb prosthetic sockets based on ISO 10328:2016 and provide the mechanical design of the loading plates, 2) apply the testing system to a series of laminated sockets, and 3) for each type of distal adapter, identify the combinations of stratigraphy and matrix with acceptable strength and minimum weight.
View Article and Find Full Text PDF