Background And Objectives: Neoadjuvant chemoradiation for rectal cancer is associated with lower local recurrence rates. The objective of this study is to assess the impact of neoadjuvant therapy on perioperative complications in patients with rectal cancer.
Methods: Using the ACS-NSQIP database (2005-2012), a propensity score was used to match 3592 patients with rectal cancer receiving neoadjuvant therapy to 3592 patients undergoing surgery alone.
Objective(s): The monopolar "Bovie" is used in virtually every laparoscopic operation. The active electrode and its cord emit radiofrequency energy that couples (or transfers) to nearby conductive material without direct contact. This phenomenon is increased when the active electrode cord is oriented parallel to another wire/cord.
View Article and Find Full Text PDFBackground: Energy-based devices are used in virtually every operation. Our purposes were to describe causes of energy-based device complications leading to injury or death, and to determine if common mechanisms leading to injury or death can be identified.
Study Design: The FDA's Manufacturer and User Facility Device Experience (MAUDE) database was searched for surgical energy-based device injuries and deaths reported over 20 years (January 1994 to December 2013).
Background: Pneumoperitoneum on computed tomography (CT) after abdominal surgery is common, but its incidence, duration, and clinical significance is widely debated.
Materials And Methods: A retrospective, cohort study of patients who underwent abdominal CT within 30 days of abdominal surgery.
Results: Among 344 patients, pneumoperitoneum was found in 39% (135/344) of patients on postoperative days 0-6 in 53%, 7-13 in 41%, 14-20 in 23%, 21-27 in 13%, and 28-30 in 0%.
Background: The monopolar "Bovie" instrument emits radiofrequency energy that can disrupt the function of other implanted electronic devices through a phenomenon termed electromagnetic interference. The purpose of this study was to quantify the electromagnetic interference occurring on cardiac implantable devices (CIEDs) resulting from monopolar instrument use in common, modifiable clinical scenarios.
Study Design: Three anesthetized pigs underwent CIED placement (1 pacemaker and 2 defibrillators).
Objective: The purpose of this study was to determine the relationship between the Timed Up and Go test and postoperative morbidity and 1-year mortality, and to compare the Timed Up and Go to the standard-of-care surgical risk calculators for prediction of postoperative complications.
Methods: In this prospective cohort study, patients 65 years and older undergoing elective colorectal and cardiac operations with a minimum of 1-year follow-up were included. The Timed Up and Go test was performed preoperatively.
Background: The purpose of this study was to compare histologic evidence of thermal injury at the epigastric and umbilical incisions after elective laparoscopic cholecystectomy performed using the monopolar "Bovie" instrument set on the higher voltage coag mode versus the lower voltage blend mode. We hypothesized that the higher voltage coag mode would create more unintended thermal tissue injury at the epigastric trocar's incision.
Methods: A prospective blinded randomized controlled trial of patients undergoing elective laparoscopic cholecystectomy was performed.
Objectives: (1) To determine if antenna coupling occurs in common operating room scenarios. (2) To define modifiable clinical variables that reduce the magnitude of antenna coupling.
Background: Mechanisms of electrosurgical burns where monitoring devices contact the surgical patient are unclear.
Background: Electromagnetic coupling can occur between the monopolar "Bovie" instrument and other laparoscopic instruments without direct contact by a phenomenon termed antenna coupling. The purpose of this study was to determine if, and to what extent, radiofrequency energy couples to other common laparoscopic instruments and to describe practical steps that can minimize the magnitude of antenna coupling.
Methods: In a laparoscopic simulator, monopolar radiofrequency energy was delivered to an L-hook.
Background: This study aimed to quantify the clinical parameters of mono- and bipolar instruments that inhibit pacemaker function. The specific aims were to quantify pacer inhibition resulting from the monopolar instrument by altering the generator power setting, the generator mode, the distance between the active electrode and the pacemaker, and the location of the dispersive electrode.
Methods: A transvenous ventricular lead pacemaker overdrive paced the native heart rate of an anesthetized pig.
Background: Energy devices are essential laparoscopic tools. Residual heat is defined as the increased instrument temperature after energy activation is completed. This study aimed to determine the length of time a surgeon needs to wait before touching other tissue using four common laparoscopic energy sources.
View Article and Find Full Text PDFSurg Laparosc Endosc Percutan Tech
October 2010
Purpose: To determine the factors that can be modified by the surgeon to reduce monopolar electrosurgery capacitive coupling during laparoscopy. Specific aims were to determine the capacitive coupling energy using different generator power settings, mode settings (cut vs. coagulation), and surgical techniques (desiccation vs.
View Article and Find Full Text PDFBackground: Electrosurgery is used in virtually every laparoscopic operation. In the early days of laparoscopic surgery, capacitive coupling, associated with hybrid trocars, was thought to be the major cause of laparoscopic electrosurgery injuries. Modern laparoscopy has reduced capacitive coupling, and now insulation failure is thought to be the main cause of electrosurgical complications.
View Article and Find Full Text PDFTreatment for most patients with upper gastrointestinal bleeding has shifted from the operating room to the endoscopy suite. Endoscopic treatment has resulted in substantial benefit for patients with bleeding from peptic ulcer. Ulcers associated with high-risk stigmata of recent hemorrhage (SRH) not treated endoscopically have 40 per cent to 100 per cent risk of continued or recurrent bleeding and up to a 35 per cent chance of requiring surgical control of bleeding.
View Article and Find Full Text PDF