Acta Chir Orthop Traumatol Cech
August 2018
Patients presenting with proximal femur fractures are at high risk of developing DVT and pulmonary embolism. Many of these patients suffer from additional anticoagulant treatment. Patients on anticoagulation treatment are complex to manage, especially regarding timing of surgery due to implemented quality control recommendations.
View Article and Find Full Text PDFActa Chir Orthop Traumatol Cech
March 2017
Introduction The intrapelvic approach was originally described by Hirvensalo et al. from Finland in the early 90ies (8) and a further comparable description was published shortly thereafter by Cole et al. (5).
View Article and Find Full Text PDFActa Chir Orthop Traumatol Cech
February 2017
The ilioinguinal approach is one of the standard approaches in the treatment of displaced acetabular fractures used during the last decades (9). The meta-analysis of Giannoudis et al. showed that 21.
View Article and Find Full Text PDFBackground: The new IOFIX is an intra-osseous fixation device comprising an "X-post" through which a lag screw passes to apparently improve force distribution across an arthrodesis. We conducted a novel human cadaveric study. Our null hypothesis was no difference in force exists in an ankle arthrodesis model stabilized with the IOFIX or a conventional single lag screw.
View Article and Find Full Text PDFThe AO Foundation advocates the use of partially threaded lag screws in the fixation of fractures of the medial malleolus. However, their threads often bypass the radiodense physeal scar of the distal tibia, possibly failing to obtain more secure purchase and better compression of the fracture. We therefore hypothesised that the partially threaded screws commonly used to fix a medial malleolar fracture often provide suboptimal compression as a result of bypassing the physeal scar, and proposed that better compression of the fracture may be achieved with shorter partially threaded screws or fully threaded screws whose threads engage the physeal scar.
View Article and Find Full Text PDFBackground: Posterolateral tibial plateau shear fractures often require buttress plating, which can be performed through a posterolateral approach. The purpose of this study was to provide accurate data about the inferior limit of dissection.
Methods: Forty unpaired cadaver adult lower limbs were used.
Purpose: Low anterior external fixators are constructed by placing half pins in the dense bone tunnel of the supra-acetabular region in an anterior to posterior direction. Although the placement of these pins is extra-articular, they may still breach the hip capsule on the anterior inferior iliac spine and thus be intra-capsular. We aim to provide radiological markers for the most superior fibres of the capsule to allow safe extra-capsular pin placement within the supra-acetabular bone tunnel.
View Article and Find Full Text PDFIntroduction: Drilling is an integral part of almost all boney operations. Various anatomical structures coursing close to the bone are at risk if the drill bit projects beyond the far cortex. Aim of this study was to evaluate and quantify the depth to which surgeons over drill beyond the far cortex.
View Article and Find Full Text PDFJ Hand Surg Eur Vol
June 2012
We measured the length of the distal radius that can be exposed by mobilizing the distal edge of pronator quadratus (PQ) without detaching its radial attachment. Measurements were made in 20 cadaveric upper limbs from the distal margin of the radius in line with the scaphoid and lunate fossae to the distal margin of the PQ, before and after mobilization of the muscle from its distal attachment. The mean distance from the distal edge of the PQ to the scaphoid fossa was 13.
View Article and Find Full Text PDFArch Orthop Trauma Surg
November 2011
Background: Post-operative knee pain is common following retrograde nailing, with its etiology often multifactorial although a well-established cause is nail protrusion from the intercondylar notch. The aim of this study was to assess the structures at risk if the nail is left proud of the femoral articular surface.
Methods: A retrograde femoral nail (Synthes Distal Femoral Nail) was inserted into the distal femur of 15 cadaveric lower limbs using the standard technique.
Objectives: Current literature describes improved clinical outcomes and a minor rate of pseudoarthrosis following operatively treated clavicular fractures. We investigated the feasibility of using a standard 3.5 mm AO locking compression plate (LCP) of adequate length for the stabilisation of mid-shaft fractures of the clavicle.
View Article and Find Full Text PDFAim: The aim of our study was to identify the structures which may be at risk of injury when using a minimally invasive technique for the osteosynthesis of the lateral malleolus and the influence of the size of the implant on the frequency of injury to these structures.
Method: Forty plates were percutaneously inserted in 20 cadaveric legs. The region around the plate was then dissected to examine the relation of nerves and soft tissues to the plate.
Arch Orthop Trauma Surg
June 2011
Introduction: Injections into the subtalar joint may be performed for diagnostic or therapeutic reasons. The anterolateral approach is most commonly utilised for this purpose. We evaluated the success of an intra-articular puncture by using the anterolateral in comparison to the posterolateral approach.
View Article and Find Full Text PDFPurpose: The aim of this study was to provide guidance on the safe zones for the exposure of the proximal radius by measuring the distance from the PIN to various anatomical landmarks in the proximal forearm in pronation and supination.
Methods: Twenty cadaveric arms were used for this study. On the anterior aspect of the forearm, the distance between insertion of the biceps tendon and the arcade of Frohse as well as the shortest distance between the PIN and the ulnar aspect of the radial neck were measured.
We examined the variation in the origin of the tibialis anterior muscle from the lateral aspect of the tibial shaft and interosseous membrane as well as the variation in the morphology of its musculotendinous junction. Forty cadaveric lower leg specimens (20 right and 20 left) were dissected to reveal the anterior compartment. The origin of the tibialis anterior muscle and its relation to the lateral tibial shaft and interosseous membrane were determined.
View Article and Find Full Text PDFScaphoid fracture fixation using a cannulated headless compression screw and the Matti-Russe procedure for the treatment of scaphoid nonunions are performed routinely. Surgeons performing these procedures need to be familiar with the anatomy of the scaphoid. A literature review reveals relatively few articles on this subject.
View Article and Find Full Text PDFInjection or aspiration of the ankle may be performed through either an anteromedial or an anterolateral approach for diagnostic or therapeutic reasons. We evaluated the success of an intra-articular puncture in relation to its site in 76 ankles from 38 cadavers. Two orthopaedic surgical trainees each injected methylene blue dye into 18 of 38 ankles through an anterolateral approach and into 20 of 38 through an anteromedial.
View Article and Find Full Text PDFThe aims of this study were to measure the size of Lister's Tubercle, the extent of the extensor pollicis longus (EPL) groove and the dihedral angle of the distal dorsal radius. Computer tomography scans of 30 forearms were performed by using a 64-slice Siemens SOMATOM Sensation CT system (Resolution 0.6 mm).
View Article and Find Full Text PDFIntra-articular punctures and injections are performed routinely on patients with injuries to and chronic diseases of joints, to release an effusion or haemarthrosis, or to inject drugs. The purpose of this study was to investigate the accuracy of placement of the needle during this procedure. A total of 76 cadaver acromioclavicular joints were injected with a solution containing methyl blue and subsequently dissected to distinguish intra- from peri-articular injection.
View Article and Find Full Text PDFPurpose: Stabilization of humeral shaft and elbow fractures can be achieved with an external-fixator. Reports about nerve injuries associated with this procedure are rare in literature. Purpose of this anatomical study was to examine the relation of the radial nerve to distal humeral half pins.
View Article and Find Full Text PDFThe extensor carpi radialis longus tendon and the extensor carpi radialis brevis tendon are important landmarks for the dorsoradial approach to the wrist. This case report presents an anatomic variant: both tendons are divided into two different reins. Knowledge about this anatomic variant is of importance in order to avoid misinterpretations.
View Article and Find Full Text PDFIntroduction: The object of this study was to assess the risk of injury to tendons, nerves and vessels in percutaneous antegrade scaphoid fracture fixation.
Methods: Forty cadaveric forearms were used in this study. A guide wire for cannulated headless compression screws was inserted percutaneously in each scaphoid according to established surgical technique.
The frequency of penetration into the third extensor compartment when drilling the distal screw holes was assessed for four different palmar distal radius plates in 160 cadaver forearms. Penetration into this compartment occurred in 43%. Different plates had different penetration rates: 3.
View Article and Find Full Text PDFPercutaneous stabilisation of tibial fractures by locking plates has become an accepted form of osteosynthesis. A potential disadvantage of this technique is the risk of damage to the neurovascular bundles in the anterior and peroneal compartments. Our aim in this anatomical study was to examine the relationship of the deep peroneal nerve to a percutaneously-inserted Less Invasive Stabilisation System tibial plate in the lower limbs of 18 cadavers.
View Article and Find Full Text PDF