Objective: The objective of this study is to compare the value of monoexponential and biexponential approach to the diffusion-weighted magnetic resonance imaging signal in the prediction of the liver fibrosis.
Methods: Forty patients with hepatitis C were included. Quantification of the apparent diffusion coefficient (ADC) and pure molecular diffusion (D), pseudodiffusion (D*), and perfusion fraction (f) was performed using 9 b values (b = 0, 20, 50, 100, 200, 400, 600, 800, 1000 s/mm).
Purpose: Obesity is a well-known of risk factor for atherosclerosis and the amount of visceral adipose tissue is considered as an independent predictor of coronary artery disease (CAD). An aim of the study was to investigate the distribution of intrathoracic adipose tissue in morbidly obese patients.
Material And Methods: Fifty-one patients with morbid obesity (BMI ≥ 40 kg/m) and thirty controls were scanned in a coronary calcium scoring protocol.
Background: Routine imaging follow-up after endovascular treatment of abdominal aortic aneurysms (EVAR) is mainly aimed at detection of endoleaks. The aim of the study was to assess changes in the size of the abdominal aortic aneurysm sack using CT angiography (CTA) after successful treatment using endovascular stent graft implantation.
Material/methods: A retrospective analysis of CTA results included 102 patients aged 54-88, who had no postoperative complications.
Background: Atrial fibrillation (AF) is a common supraventricular arrhythmia. ECG-gated MDCT seems to be currently a method of choice for pre-ablation anatomical mapping due to an excellent resolution and truly isotropic three-dimensional nature. The aim of this study was to establish the between-subject variability and inter-observer reproducibility of anatomical evaluation of the pulmonary veins (PV) and the left atrium (LA) using computed tomography.
View Article and Find Full Text PDFPurpose: MR elastography (MRE) is a recent non-invasive technique that provides in vivo data on the viscoelasticity of the liver. Since the method is not well established, several different protocols were proposed that differ in results. The aim of the study was to analyze the variability of stiffness measurements in different regions of the liver.
View Article and Find Full Text PDFObjective: To determine differences in coronary artery calcium (CAC) measurement performed with the use of 2 generations of multidetector computed tomography (CT) scanners of the same manufacturer.
Methods: Agatston Score (AS) and calcium mass (CM) were measured with a 4-row scanner (AS4 and CM4) and a 64-row scanner (AS64 and CM64) using a cardiac phantom with calcium inserts.
Results: The results of the AS measurements (mean ± SD) varied significantly between the equipment: 880.