Many fundamental aspects of New York State's climate have already begun to change, and the changes are projected to continue-and in some cases, accelerate-throughout the 21st century. This chapter explores observed and projected changes in a variety of physical variables that relate directly to weather and climate, starting with average and extreme air temperature and proceeding to the associated effects on precipitation, extreme events, and core properties of New York's coastal and inland waters. These climate attributes and hazards lead to impacts throughout the eight sectors of this assessment.
View Article and Find Full Text PDFObjective: To construct and validate an instrument to assess events related to maintaining the sterility of processed healthcare products.
Methods: This methodological study developed the instrument through analysis by a panel of experts, focusing on the integrity of commonly used packaging: spunbond-meltblown-spunbond and medical-grade paper. The instrument was analyzed using the Content Validity Index and Content Validity Ratio (≥ 0.
Infect Control Hosp Epidemiol
December 2023
Background: The complex design of cannulas is a major challenge for reprocessing due to the retention and accumulation of fat residues.
Aim: To evaluate the cleaning of liposuction cannulas and the protective effects of the remaining fat residues on Mycobacterium abscessus subspecies bolletii (MASB) and Geobacillus stearothermophilus inactivation during steam sterilization.
Methods: In phase 1, six standard operating procedures were evaluated for cleaning of liposuction cannulas.
Infect Control Hosp Epidemiol
May 2023
Int Arch Otorhinolaryngol
July 2022
Currently, there is no safe, affordable, and ecologically-sustainable guideline that helps prevent contamination through endoscopy. We evaluated the safety of intermediate-level disinfection with 70% ethyl alcohol (w/v) based on biological-load recovery from rigid endoscopes after nasal endoscopy. To demonstrate the efficacy of 70% ethanol in disinfecting rigid endoscopes (REs) to reduce microbial growth in microbiological cultures.
View Article and Find Full Text PDFFlooding is expected to increase due to intensification of extreme precipitation events, sea-level rise, and urbanization. Low-cost water level sensors have the ability to fill a critical data gap on the presence, depth, and duration of street-level floods by measuring flood profiles (i.e.
View Article and Find Full Text PDFInfect Control Hosp Epidemiol
May 2023
We analyzed the effectiveness of manual cleaning protocols performed on high-speed dental handpieces, using protein identification by fluorescence. Although one protocol was able to able to lower the amount of protein, >40% of the handpieces showed amounts of residual protein at unacceptable levels.
View Article and Find Full Text PDFObjective: to compare the efficacy of 80% (w/v) alcohol, rubbed for 30 and 60 seconds, in the manual processing of stainless-steel wash bowls, after cleaning with running water and neutral detergent.
Method: experimental study conducted in a hospital in the state of São Paulo, Brazil, on 50 bowls randomly divided into two groups of 25 bowls each for interventions of 30 and 60 seconds of rubbing with 80% (w/v) alcohol.
Results: based on the microbiological analyses collected, before and after the interventions for both groups, partial efficacy of the disinfectant was observed even when extending rubbing time.
Aerosolization may occur during reprocessing of medical devices. With the current coronavirus disease 2019 pandemic, it is important to understand the necessity of using respirators in the cleaning area of the sterile processing department. To evaluate the presence of severe acute respiratory syndrome coronavirus (SARS-CoV-2) in the air of the sterile processing department during the reprocessing of contaminated medical devices.
View Article and Find Full Text PDFObjective: Guidelines recommend that the cleaning area in a Central Sterile Supply Department (CSSD) maintain a negative pressure of the environmental air, but how much this system can impact the contamination of the air by bioaerosols in the area is not known. The objective of this study was to assess the impact of negative pressure on CSSD by evaluating the microbiological air quality of this sector.
Methods: Microbiological air samples were collected in two CSSD in the same hospital: one with and one without a negative air pressure system.
Background: Pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) have reduced mortality and improved the quality of life of cardiac patients. However, the high cost of these devices prevents their large-scale incorporation, particularly in low-income countries, where reusing explanted PMs/ICDs has become an alternative.
Methods: A systematic review and meta-analysis were conducted of studies that compare infection rates, device-related deaths, malfunction and premature battery depletion in patients with reused PM and ICD implants and those with new devices.
This study aimed to compare the antimicrobial action of three soaps for hand hygiene (HH): 2.0% Tea Tree Oil (TTO); 0.5% triclosan; 2.
View Article and Find Full Text PDFBackground: The risk concerning the presence of non-condensable gases (NCGs) has already been demonstrated, but routine monitoring still requires further research to be implemented in each sterilization cycle.
Aim: Performance evaluation of the physical, chemical and biological indicators used in monitoring in comparison with a sterilizer integrated detector for NCG in the Sterilization Process.
Methods: Chemical indicators (type 2 Bowie-Dick test, type 5 and type 6 models), self-contained biological indicators and physical indicators (temperature, pressure, thermal qualification and a patented integrated air detector) were used to monitor the steam sterilization process in two situations of controlled failure: chamber leakage and door seal failure.
Biomed Instrum Technol
September 2020
This review sought to provide an overview of proposed methods and protocols for processing surgical instruments contaminated with prions. A search of PubMed was conducted to identify studies published between January 1, 2012, and January 2, 2019, with no language restrictions and using varying combinations of the following terms: prions (Medical Subject Heading [MeSH]) OR decontamination (MeSH) OR cleaning OR disinfection OR sterilization. Articles were excluded if they did not involve medical device surfaces or describe the processing protocol.
View Article and Find Full Text PDFChemical indicators are commonly used in hospitals to monitor steam sterilization conditions, indicating that medical devices are safe to be used. The results are stored for future evidence in the event of an infection incident root cause analysis. This type of indicator is also becoming an option for cycle monitoring in pharmaceutical steam sterilizers, improving cycle control.
View Article and Find Full Text PDFCleaning cannulated medical devices can be challenging for perioperative and sterile processing department personnel. We performed a laboratory experimental study to evaluate differences in cleaning effectiveness using either a back-and-forth or helical spinning brushing motion and the effect of rinsing the bristles at each reintroduction of the brush in the lumen. We also tested the lumen cleanliness after high-pressure water cleansing without brushing.
View Article and Find Full Text PDFChemical indicators are commonly used in hospitals to monitor steam sterilization conditions, indicating that medical devices are safe to be used. The results are stored for future evidence in the event of an infection incident root cause analysis. This type of indicator is also becoming an option for cycle monitoring in pharmaceutical steam sterilizers, improving cycle control.
View Article and Find Full Text PDFObjective: To determine if the standardized B&D type test for hospital steam sterilizer is correctly indicating cycle failures in slower come-up ramps cycles.
Methods: Two commercially available B&D type test were challenged in a quality control sterilizer. A common failure was simulated in triplicate cycles, using a standardized cycle configuration, and then compared to triplicate cycles of a common cycle configuration.
Objective: To evaluate the efficacy of detergent and friction on removal of traditional biofilm and cyclic-buildup biofilm (CBB) from polytetrafluoroethylene (PTFE) channels and to evaluate the efficacy of glutaraldehyde to kill residual bacteria after cleaning.
Methods: PTFE channels were exposed to artificial test soil containing 108 CFU/mL of Pseudomonas aeruginosa and Enterococcus faecalis, followed by full cleaning and high-level disinfection (HLD) for five repeated rounds to establish CBB. For traditional biofilm, the HLD step was omitted.
Biomed Instrum Technol
September 2019
Currently, there are two orthopedic implant types: (1) Sterile implants (e.g., joint prostheses) are distributed in a ready-for-use sterile fashion, and (2) nonsterile implants (e.
View Article and Find Full Text PDFBackground: The dispersal of airborne norovirus (NoV) particles from the floor after contamination with faeces or vomit is a challenge for infection control, as this pathogen is infectious at low doses. Therefore, it is imperative to establish a safe protocol for floor decontamination.
Aim: To assess the presence of residual NoV-GII particles on floors and airborne particles following various floor decontamination procedures.
Infect Control Hosp Epidemiol
January 2018
OBJECTIVE To compare the effectiveness of manual and automated methods for cleaning laparoscopic instruments. DESIGN Experimental laboratory study. METHODS We evaluated 4 methods of cleaning laparoscopic instruments: (1) manual-only cleaning and rinsing with potable tap water; (2) manual cleaning and rinsing with potable tap water, followed by ultrasonic cleaning without rinsing; (3) manual cleaning and rinsing with potable tap water followed by ultrasonic cleaning and rinsing with potable tap water; and (4) manual cleaning and rinsing with potable tap water, followed by ultrasonic cleaning and rinsing: first with potable tap water and then with sterile distilled water.
View Article and Find Full Text PDFObjective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination.
Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator.
A high-speed handpiece is used in several dental procedures and the official recommendation for safe decontamination consists of rinsing with water, washing with detergent, mechanical friction, and sterilization; however, many professionals only apply 70% w/v alcohol without also cleaning the tool between patients. We performed an analysis of high-speed handpieces reprocessed only with 70% w/v alcohol and found that the methods used in clinical practice are not safe.