Background: For patients with high grade serous carcinoma of the ovary (HGSC), survival rates have remained static for the last half century. Despite the presence of tumor mutations and infiltration of immune cells, existing immunotherapies have achieved little success against HGSC. These observations highlight a gap in the understanding of how the immune system functions and interacts within HGSC tumors.
View Article and Find Full Text PDFAs the COVID-19 pandemic was overtaking the world in the spring of 2020, the National Institute of Standards and Technology (NIST) began collaborating with the National Biodefense Analysis and Countermeasures Center to study the inactivation of SARS-CoV-2 after exposure to different ultraviolet (UV) and blue light wavelengths. This paper describes a 1 kHz pulsed laser and projection system used to study the doses required to inactive SARS-CoV-2 over the wavelength range of 222 to 488 nm. This paper builds on NIST's previous work for water pathogen inactivation using UV laser irradiation.
View Article and Find Full Text PDFNumerous studies have demonstrated that SARS-CoV-2 can be inactivated by ultraviolet (UV) radiation. However, there are few data available on the relative efficacy of different wavelengths of UV radiation and visible light, which complicates assessments of UV decontamination interventions. The present study evaluated the effects of monochromatic radiation at 16 wavelengths from 222 nm through 488 nm on SARS-CoV-2 in liquid aliquots and dried droplets of water and simulated saliva.
View Article and Find Full Text PDFJ Res Natl Inst Stand Technol
August 2021
This paper describes advances in measuring the characteristic spatial distribution of surface temperature and emissivity during laser-metal interaction under conditions relevant for laser powder bed fusion (LPBF) additive manufacturing processes. Detailed descriptions of the measurement process, results, and approaches to determining uncertainties are provided. Measurement uncertainties have complex dependencies on multiple process parameters, so the methodology is demonstrated on one set of process parameters and one material.
View Article and Find Full Text PDFMelt pool monitoring (MPM) is a technique used in laser powder bed fusion (LPBF) to extract features from insitu sensor signals that correlate to defect formation or general part fabrication quality. Various melt pool phenomena have been shown to relate to measured transient absorption of the laser energy, which in turn, can be relatable to the melt pool emission measured in MPM systems. This paper describes use of a reflectometer-based instrument to measure the dynamic laser energy absorption during single-line laser scans.
View Article and Find Full Text PDFThe immune landscape of a tumor is highly connected to patient prognosis and response to treatment, but little is known about how natural killer (NK) cells predict overall survival (OS) among patients with solid tumors. We present the first meta-analysis on NK cell infiltration into solid tumors as a prognostic indicator for OS, considering cancer types independently, and together. Samples were collected from 1973 to 2016 with results published between 1989 and 2020.
View Article and Find Full Text PDFWe have designed a non-imaging telescope for measurement of the spectral irradiance of the moon. The telescope was designed to be integrated into a wing pod of a National Aeronautics and Space Administration ER-2 research aircraft to measure lunar spectral irradiance during flight. The telescope and support system were successfully flown in August 2018 at altitudes near 21 km and at speeds of ∼760 km/h.
View Article and Find Full Text PDFHigh-speed thermography is useful tool for researching the laser powder bed fusion process by providing thermal information in heat affected zone. However, it is not directly possible to ascertain the position of the laser spot with respect to the melt pool, which could provide key information regarding how laser energy is distributed and absorbed. In this paper, we demonstrate a procedure for registering the laser spot position with the melt pool using a bright illumination source co-axially aligned with the laser to project a sharp spot on the build plane.
View Article and Find Full Text PDFOvarian cancer (OC) is diagnosed in ~22,000 women in the US each year and kills 14,000 of them. Often, patients are not diagnosed until the later stages of disease, when treatment options are limited, highlighting the urgent need for new and improved therapies for precise cancer control. An individual's immune function and interaction with tumor cells can be prognostic of the response to cancer treatment.
View Article and Find Full Text PDFLearn Health Syst
October 2018
Objective: Efficacy of neuromuscular electrical stimulation (NMES) is limited by the discomfort of electrically elicited contractions. Most studies of tolerance to NMES have examined stimulation to maximal tolerance. NMES efficiency is the amount of elicited force at a specific level of tolerance.
View Article and Find Full Text PDFAlthough individuals enrolled in both Medicare and Medicaid (dual eligibles) are among those with the nation's greatest need, at $300 billion per year, their care is also expensive and beset by quality problems. Previous research found problems associated with inadequate coordination of benefits and services; however, these studies have largely used quantitative approaches and focused on providers-few studies have explored the perspective of dual eligible patients. In an effort to improve care and reduce costs, North Carolina (NC) developed a Patient-Centered Medical Home (PCMH) model centered on a continuous relationship with a primary care provider who is responsible for coordination of services and addressing patients' health care needs by providing direct services or arranging care with other qualified professionals.
View Article and Find Full Text PDFThe National Institute of Standards and Technology's (NIST) Physical Measurement and Engineering Laboratories are jointly developing the Additive Manufacturing Measurement Testbed (AMMT)/ Temperature and Emittance of Melts, Powders and Solids (TEMPS) facilities. These facilities will be co-located on an open architecture laser-based powder bed fusion system allowing users full access to the system's operation parameters. This will provide users with access to machine-independent monitoring and control of the powder bed fusion process.
View Article and Find Full Text PDFCardiac rehabilitation (CR) use is lower for racial and ethnic minorities than White patients. The purpose of this study was to identify factors that drive this disparity at the system, provider, and patient levels. A mixed methods study combined descriptive analysis of 2007 Medicare claims data and thematic analysis of 19 clinician interviews, 8 minority patient focus groups and 8 one-on-one interviews with minority heart patients across three communities.
View Article and Find Full Text PDFBackground: Along history, music has been used in a variety of ways for therapeutic purposes and has long been recognized for its physiological and psychological effects. Music listening can be an effective nursing intervention, to enhance relaxation, provide distraction, and reduce pain.
Objectives: The aims of this study were to identify changes produced by different musical stimuli in blood pressure (BP), heart rate (HR), respiratory rate (RR), and oxygen saturations (SpO2) and to verify the influence of music listening on patients' facial expressions with severe cerebral damage.
Background: Much attention has been paid to improving the care of patients with cardiovascular disease by focusing attention on delivery system redesign and payment reforms that encompass the healthcare spectrum, from an acute episode to maintenance of care. However, 1 area of cardiovascular disease care that has received little attention in the advancement of quality is cardiac rehabilitation (CR), a comprehensive secondary prevention program that is significantly underused despite evidence-based guidelines that recommending its use.
Purpose: The purpose of this article was to analyze the applicability of 2 payment and reimbursement models-pay-for-performance and bundled payments for episodes of care--that can promote the use of CR.
Background: The cervical vestibular evoked myogenic potential (cVEMP) is recorded from the sternocleidomastoid muscle (SCM) and represents a stimulus-evoked attenuation of electromyographic (EMG) activity following activation of the saccule and inferior vestibular nerve. In addition to the cVEMP, it is possible to record a biphasic response from the infraorbital region following stimulation that is identical to that used to record the cVEMP. This response is known as the ocular VEMP (oVEMP).
View Article and Find Full Text PDFBackground: Postural stability in humans is largely maintained by vestibular, visual, and somatosensory inputs to the central nervous system. Recent clinical advances in the assessment of otolith function (e.g.
View Article and Find Full Text PDFBefore being used in an extreme-ultraviolet (EUV) scanner, photoresists must first be evaluated for sensitivity and tested to ensure that they will not contaminate the scanner optics. The new NIST facility described here provides data on the contamination potential of the outgas products of a candidate resist by simultaneously irradiating a multilayer optic and a nearby resist-coated wafer with EUV radiation. The facility can also be used without changing its configuration to provide accurate resist dose-to-clear measurements.
View Article and Find Full Text PDFObjective: The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States.
Design: A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine.
A free standing transmission grating based imaging spectrometer in the extreme ultraviolet range has been developed for the National Spherical Torus Experiment (NSTX). The spectrometer operates in a survey mode covering the approximate spectral range from 30 to 700 Å and has a resolving capability of δλ/λ on the order of 3%. Initial results from space resolved impurity measurements from NSTX are described in this paper.
View Article and Find Full Text PDF