Publications by authors named "Granstedt E"

A 2D imaging instrument has been designed and deployed on C-2W ("Norman") [H. Gota et al., Nucl.

View Article and Find Full Text PDF

In order to measure the fast ion using neutral particle analyzers (NPAs) in the low neutral density core region of a magnetic confinement fusion device, active change exchange measurements are often performed using a neutral beam (NB) as a charge-exchange (CX) target. One of the complications with this approach is that an NB injected as a CX target can also contribute to the total fast ion source. C-2W has a unique solution to this difficulty in that it is equipped with both eight NB injectors, which can inject beams of different particle species, and an electro-magnetic NPA (EM-NPA), which can measure multiple ion species simultaneously.

View Article and Find Full Text PDF

In TAE Technologies' current experimental device, C-2W (also called "Norman"), record-breaking, advanced beam-driven field-reversed configuration plasmas are produced and sustained in steady state utilizing variable energy neutral beams, advanced divertors, edge-biasing electrodes, and an active plasma control system [Gota et al., Nucl. Fusion 61, 106039 (2021)].

View Article and Find Full Text PDF

The C-2W device ("Norman") [Gota et al., Nucl. Fusion 59, 112009 (2019)] has produced and sustained beam-driven field-reversed configuration (FRC) plasmas embedded in a magnetic mirror geometry using neutral beams and end-bias electrodes located in expander divertors.

View Article and Find Full Text PDF

In the current experimental device of TAE Technologies, C-2W (also called "Norman"), record breaking advanced beam-driven field-reversed configuration (FRC) plasmas are produced and sustained in steady state utilizing variable energy neutral beams (15-40 keV, total power up to 20 MW), advanced divertors, bias electrodes, and an active plasma control system. This fully operational experiment is coupled with a fully operational suite of advanced diagnostic systems. The suite consists of 60+ individual systems spanning 20 categories, including magnetic sensors, Thomson scattering, interferometry/polarimetry, spectroscopy, fast imaging, bolometry, reflectometry, charged and neutral particle analysis, fusion product detection, and electric probes.

View Article and Find Full Text PDF

Two filtered, fast-imaging instruments, with radial and axial views, respectively, were used on the C-2U device to visualize line emission from impurities and hydrogenic neutrals. Novel calibration techniques needed to be developed for these instruments because the accelerated pace of C-2U operations precluded access to the interior of the vacuum vessel, targets used in typical calibration methods were not available, and in order to account for effects which have not been sufficiently addressed in the literature. Spatial calibration involved optimizing parameters in a generic camera model: using a checkerboard target and using the vacuum vessel port geometry.

View Article and Find Full Text PDF

A suite of diagnostics was developed to measure particle and heat fluxes arriving at the divertor electrodes of the C-2W experiment at TAE Technologies. The divertor electrodes consist of 4 concentric rings, each equipped with a bolometer, electrostatic energy analyzer, and thermocouple mounted at two opposing azimuthal locations. These probes provide measurements of the power flux to the divertor electrodes as well as measurements of the ion current density, ion energy distribution, and total energy deposition.

View Article and Find Full Text PDF

The new C-2W Thomson scattering (TS) diagnostic consists of two individual subsystems for monitoring electron temperature (T) and density (n): one system in the central region is currently operational, and the second system is being commissioned to monitor the open field line region. Validating the performance of the TS's custom designed system components and unique calibration of the detection system and diagnostic as a whole is crucial to obtaining high precision T and n profiles of C-2W's plasma. The major components include a diode-pumped Nd:YAG laser which produces 35 pulses at up to 20 kHz, uniquely designed collection lenses with a fast numerical aperture, and uniquely designed polychromators with filters sets to optimize a T ranging from 10 eV to 2 keV.

View Article and Find Full Text PDF

Active control of field reversed configuration (FRC) devices requires a method to determine the flux surface geometry and dynamic properties of the plasma during both transient and steady-state conditions. The current tomography (CT) method uses Bayesian inference to determine the plasma current density distribution using both the information from magnetic measurements and a physics model in the prior. Here we show that, from the inferred current sources, the FRC topology and its axial stability properties are readily obtained.

View Article and Find Full Text PDF

The first measurements of fast-ion D-alpha (FIDA) radiation have been acquired on C-2U, Tri Alpha Energy's advanced, beam-driven field-reversed configuration (FRC). These measurements are also forward modeled by FIDASIM. This is the first measurement and simulation of FIDA carried out on an FRC topology.

View Article and Find Full Text PDF

A project has been started at ORNL to develop a dual-wavelength digital holography system for plasma facing component erosion measurements on prototype material plasma exposure experiment. Such a system will allow in situ real-time measurements of component erosion. Initially the system will be developed with one laser, and first experimental laboratory measurements will be made with the single laser system.

View Article and Find Full Text PDF

The C-2U device employed neutral beam injection, end-biasing, and various particle fueling techniques to sustain a Field-Reversed Configuration (FRC) plasma. As part of the diagnostic suite, two fast imaging instruments with radial and nearly axial plasma views were developed using a common camera platform. To achieve the necessary viewing geometry, imaging lenses were mounted behind re-entrant viewports attached to welded bellows.

View Article and Find Full Text PDF

An instrument was developed using digital holographic reconstruction of the wavefront from a CO2 laser imaged on a high-speed commercial IR camera. An acousto-optic modulator is used to generate 1-25 μs pulses from a continuous-wave CO2 laser, both to limit the average power at the detector and also to freeze motion from sub-interframe time scales. Extensive effort was made to characterize and eliminate noise from vibrations and second-surface reflections.

View Article and Find Full Text PDF

In situ, real time measurement of net plasma-facing-component (PFC) erosion/deposition in a real plasma device is challenging due to the need for good spatial and temporal resolution, sufficient sensitivity, and immunity to fringe-jump errors. Design of a high-sensitivity, potentially high-speed, dual-wavelength CO2 laser digital holography system (nominally immune to fringe jumps) for PFC erosion measurement is discussed.

View Article and Find Full Text PDF

There has been a long-standing collaboration between ORNL and PPPL on edge and boundary layer physics. As part of this collaboration, ORNL has a large role in the instrumentation and interpretation of edge physics in the lithium tokamak experiment (LTX). In particular, a charge exchange recombination spectroscopy (CHERS) diagnostic is being designed and undergoing staged testing on LTX.

View Article and Find Full Text PDF

The state of the art in electro-optics has advanced to the point where digital holographic acquisition of wavefronts is now possible. Holographic wavefront acquisition provides the phase of the wavefront at every measurement point. This can be done with accuracy on the order of a thousandth of a wavelength, given that there is sufficient care in the design of the system.

View Article and Find Full Text PDF