Publications by authors named "Graham Beastall"

The between method variability of patient results is a source of uncertainty that can have adverse consequences for patient safety and clinical outcomes. Globalisation requires that laboratory medicine results should be transferable between methods. Traceability in laboratory medicine aims to reduce between method variability so that results are independent of time or location.

View Article and Find Full Text PDF

Healthcare delivery and responsibility is changing. Patient-centered care is gaining international acceptance with the patient taking greater responsibility for his/her health and sharing decision making for the diagnosis and management of illness. Laboratory medicine must embrace this change and work in a tripartite collaboration with patients and with the clinicians who use clinical laboratory services.

View Article and Find Full Text PDF

Laboratory medicine results influence a high percentage of all clinical decisions. Globalization requires that laboratory medicine results should be transferable between methods in the interests of patient safety. International collaboration is necessary to deliver this requirement.

View Article and Find Full Text PDF

The 7th Santorini Conference was held in Santorini, Greece, and brought together 200 participants from 40 countries in several continents, including Europe, USA but also Japan, Korea, Brazil and South Africa. The attendees had the opportunity to: listen to 60 oral presentations; participate in two lunch symposia; look at 103 posters, which were divided in two groups ('systems medicine and environment' and 'pharmacogenomics and cancer') and attend a dedicated exhibition with six companies. The meeting was organized by the Institut National de la Santé et de la Recherche Médicale (INSERM) U1122; IGE-PCV and by 'Biologie Prospective' with the collaboration of the European Society of Pharmacogenomics and Theranostics (ESPT), under the auspices of international organizations (e.

View Article and Find Full Text PDF

Given the prevalence of thyroid disorders and the subtle signs and symptoms that may accompany subclinical disease, reliable laboratory testing for serum TSH and free thyroid hormones is important for both primary care physicians and endocrinologists. The laboratory community has recognized the need for standardization of thyroid function tests to achieve comparability of measurement results between methods. This applies in particular to tests for free T4 (FT4), which may be considered controversial in terms of clinical and analytical validity.

View Article and Find Full Text PDF

Laboratory medicine is a medical specialty at the centre of healthcare. When used optimally laboratory medicine generates knowledge that can facilitate patient safety, improve patient outcomes, shorten patient journeys and lead to more cost-effective healthcare. Optimal use of laboratory medicine relies on dynamic and authoritative leadership outside as well as inside the laboratory.

View Article and Find Full Text PDF

Background: Laboratory testing of serum thyroid-stimulating hormone (TSH) is an essential tool for the diagnosis and management of various thyroid disorders whose collective prevalence lies between 4% and 8%. However, between-assay discrepancies in TSH results limit the application of clinical practice guidelines.

Methods: We performed a method comparison study with 40 sera to assess the result comparability and performance attributes of 16 immunoassays.

View Article and Find Full Text PDF

Background: Free thyroxine (FT4) and free triiodothyronine (FT3) measurements are useful in the diagnosis and treatment of a variety of thyroid disorders. The IFCC Scientific Division established a Working Group to resolve issues of method performance to meet clinical requirements.

Methods: We compared results for measurement of a panel of single donor sera using clinical laboratory procedures based on equilibrium dialysis-isotope dilution-mass spectrometry (ED-ID-MS) (2 for FT4, 1 for FT3) and immunoassays from 9 manufacturers (15 for FT4, 13 for FT3) to a candidate international conventional reference measurement procedure (cRMP) also based on ED-ID-MS.

View Article and Find Full Text PDF

Background: Because total thyroid hormone testing is performed on many automated clinical chemistry instruments, the IFCC Scientific Division commissioned the Working Group for Standardization of Thyroid Function Tests to include total thyroxine (TT4) and total triiodothyronine (TT3) in its standardization efforts.

Methods: Existing SI-traceable reference measurement procedures (RMPs) were used to assign TT4 and TT3 values to 40 single-donor serum samples for subsequent use in a method comparison study with 11 TT4 and 12 TT3 immunoassays. Data from comparison of each immunoassay with the RMPs provided a basis for mathematical assay recalibration.

View Article and Find Full Text PDF

Although statins are widely prescribed as cholesterol-lowering drugs, a number of studies suggest that these compounds may have anabolic effects on bone. Our aim was to assess whether simvastatin affects the rate of fracture healing in humans. A prospective, double-blind, randomized controlled trial was performed.

View Article and Find Full Text PDF

Education and training to become a senior professional in UK clinical biochemistry is coordinated at national level and is largely dependent upon completion of the MRCPath examination. The number of training commissions is regulated to accord with workforce planning requirements. Both medical and science graduates are eligible to undertake this training and the core curriculum is similar for both groups.

View Article and Find Full Text PDF

In the present paper the IFCC WG-STFT recommends and provides the rationale to establish metrological traceability of serum free thyroxine (FT4) measurements to a candidate international conventional reference measurement procedure. It is proposed that this procedure be based on equilibrium dialysis combined with determination of thyroxine in the dialysate with a trueness-based reference measurement procedure. The measurand is thus operationally defined as "thyroxine in the dialysate from equilibrium dialysis of serum prepared under defined conditions".

View Article and Find Full Text PDF

The EC4 Syllabus for Postgraduate Training is the basis for the European Register of Specialists in Clinical Chemistry and Laboratory Medicine. The syllabus: Indicates the level of requirements in postgraduate training to harmonise the postgraduate education in the European Union (EU); Indicates the level of content of national training programmes to obtain adequate knowledge and experience; Is approved by all EU societies for clinical chemistry and laboratory medicine. The syllabus is not primarily meant to be a training guide, but on the basis of the overview given (common minimal programme), national societies should formulate programmes that indicate where knowledge and experience is needed.

View Article and Find Full Text PDF