Publications by authors named "Grady W Miller"

To investigate whether hyperpolarised xenon-129 MRI (HXeMRI) enables regional and physiological resolution of diffusing capacity limitations in chronic obstructive pulmonary disease (COPD), we evaluated 34 COPD subjects and 11 healthy volunteers. We report significant correlations between airflow abnormality quantified by HXeMRI and per cent predicted forced expiratory volume in 1 s; HXeMRI gas transfer capacity to red blood cells and carbon monoxide diffusion capacity (%DLCO); and HXeMRI gas transfer capacity to interstitium and per cent emphysema quantified by multidetector chest CT. We further demonstrate the capability of HXeMRI to distinguish varying pathology underlying COPD in subjects with low %DLCO and minimal emphysema.

View Article and Find Full Text PDF

Unlabelled: Magnetic resonance imaging (MRI) has become the preferred modality for imaging the knee to show pathology and guide patient management and treatment. The knee is one of the most frequently injured joints, and knee pain is a pervasive difficulty that can affect all age groups. Due to the diverse pathology, complex anatomy, and a myriad of injury mechanisms of the knee, the MRI knee protocol and sequences should ensure detection of both soft tissue and osseous structures in detail and with accuracy.

View Article and Find Full Text PDF

The assessment of early pulmonary disease and its severity can be difficult in young children, as procedures such as spirometry cannot be performed on them. Computed tomography provides detailed structural images of the pulmonary parenchyma, but its major drawback is that the patient is exposed to ionizing radiation. In this context, magnetic resonance imaging (MRI) is a promising technique for the evaluation of pediatric lung disease, especially when serial imaging is needed.

View Article and Find Full Text PDF

Purpose: Evaluate feasibility of using time-resolved and high-resolution, contrast-enhanced magnetic resonance angiography (MRA) at 7 T for characterization of an animal model of pulmonary embolism.

Methods: MRAs were performed in five rabbits using a 7-T MR scanner. Preceding the MR studies, each rabbit underwent a pulmonary artery catheterization with balloon placement.

View Article and Find Full Text PDF

The purpose of this study was to assess the properties of a model system for hyperpolarized He-3 (HHe) diffusion MR imaging created from the lungs of New Zealand white rabbits by drying the lungs while inflated at constant pressure. The dried lungs were prepared by sacrificing the animal, harvesting the lungs en bloc and dehydrating the lungs for several days using dry compressed air. In four rabbits, the apparent diffusion coefficient (ADC) of HHe gas was measured in vivo and, within 1 week, in vitro in the dried lungs.

View Article and Find Full Text PDF