Tandem mass spectrometry is an important analytical tool for clinical laboratories, but tests developed and validated in-house (laboratory developed tests, or LDTs) require special consideration. In late 2022, the forecast for United States (U.S.
View Article and Find Full Text PDFAccurate measurement of thyrogloblulin (Tg) at low concentrations is essential for recurrence-monitoring in patients who have been treated for papillary and follicular thyroid cancers. The immunoassays commonly employed by clinical laboratories to measure Tg are known to suffer interferences from thyroglobulin autoantibodies (TgAb).We describe a semiautomated stable isotope standards and capture by antipeptide antibodies (SISCAPA®) LC-MS/MS method for the accurate and precise measurement of Tg using 400 uL of serum.
View Article and Find Full Text PDFAccurate determination of plasma renin activity (PRA) is essential for the development and maintenance of an effective screening program for primary aldosteronism (PA). PRA measurement can also be useful in the investigation of renal artery stenosis, syndrome of mineralocorticoid excess, Addison's disease, congenital adrenal hyperplasia, Bartters and Gitelman syndromes, and for inherited defects in the renin angiotensin aldosterone system (RAAS). We describe a semiautomated and simple method for the accurate and precise measurement of PRA from 500 μL of plasma (250 μL if blank subtraction is omitted, as discussed) using a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method for angiotensin I (AngI) in 96-well format.
View Article and Find Full Text PDFSerum IgG subclasses (IgGSC) are measured for a number of indications, but the most common are the identification of selective immunodeficiency disease and the diagnosis of IgG4-related disease (IgG4RD). Traditional nephelometric (IN) assays can suffer from two issues impacting the accuracy of the results: (1) hook effect and (2) antibody cross-reactivity between the subclasses. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is not vulnerable to these modes of interference and therefore serves as an excellent and relatively inexpensive means of diagnosing and/or monitoring the relevant clinical conditions.
View Article and Find Full Text PDFAccurate determination of serum and plasma aldosterone is essential for screening, diagnosis, and subtype classification of primary aldosteronism (PA). Its measurement is also used in the investigation of adrenal incidentaloma, adrenal carcinoma, Addison's disease, congenital adrenal hyperplasia, renal artery stenosis, and renal tubular channelopathies. We describe a simple and robust method for the accurate and precise measurement of aldosterone in serum or plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS).
View Article and Find Full Text PDFIntroduction: Hypervitaminosis D is a relatively uncommon etiology of hypercalcemia. Toxicity is usually caused by very high doses, mostly secondary to erroneous prescription or administration of vitamin D, and less commonly, contaminated foods or manufacturing errors of vitamin D-containing supplements.
Case Presentation: A 16-year-old male, previously healthy, presented with 2-week history of nonspecific symptoms (fatigue, gastrointestinal complaints).
J Mass Spectrom Adv Clin Lab
April 2022
Introduction: Hepcidin is a hormone that regulates systemic iron homeostasis. Serum hepcidin levels are under the influence of various stimuli, particularly inflammation and renal dysfunction. The measurement of hepcidin in circulation is a potentially useful clinical tool in the diagnosis, monitoring and treatment of iron metabolism disorder, although clinical interpretation of hepcidin level remains difficult.
View Article and Find Full Text PDFTestosterone (T), sex hormone binding globulin (SHBG), free testosterone (FT) and bioavailable testosterone (BAT) are commonly employed tests in pediatric endocrinology and all require age-dependent reference intervals for interpretation. The common methods used to derive these reference intervals require decisions about data shape and/or age partition thresholds, which can result in sharp differences between age groups, particularly for pubescent children. Partitioning also results in a form of data loss, where data from one age-bin is completed disconnected from the adjacent age-bins.
View Article and Find Full Text PDFObjectives: Amyloid-β (Aβ) peptides in cerebrospinal fluid (CSF), including Aβ42 (residues 1-42) and Aβ40 (residues 1-40), are utilized as biomarkers in the diagnostic workup of Alzheimer's disease. Careful consideration has been given to the pre-analytical and analytical factors associated with measurement of these peptides via immunoassays; however, far less information is available for mass spectrometric methods. As such, we performed a comprehensive evaluation of pre-analytical and analytical factors specific to Aβ quantification using mass spectrometry.
View Article and Find Full Text PDF: Serum IgG4 is typically measured to investigate for Immunoglobulin G4-related Disease (IgG4-RD), a fibroinflammatory condition associated with polyclonal increase in serum IgG4. However, increased IgG4 can also be monoclonal, and little is known about IgG4 myeloma. : We describe two cases of IgG4 myeloma without clinical, radiologic, or laboratory features of IgG4-related disease.
View Article and Find Full Text PDFIntroduction: We developed an automated liquid chromatography-tandem mass spectrometry high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for multiplex quantification of wild-type (wt) amyloid β (Aβ) peptides 1-40 (Aβ40) and 1-42 (Aβ42) and detection of variant Aβ peptides in cerebrospinal fluid.
Methods: The multiplex Aβ HPLC-MS/MS assay was validated in a clinically accredited laboratory following regulatory guidelines, with Aβ42 calibration assigned to the ERM/IFCC certified reference material; sequence variants were additionally multiplexed into the method.
Results: Sample preparation was fully automated on a liquid handler.
Infliximab is a monoclonal antibody therapy used to treat several chronic immune-mediated diseases, including Crohn's disease, ulcerative colitis, and rheumatoid arthritis. Infliximab acts by binding to tumor necrosis factor and, thus, inhibiting the inflammatory cascade. While it is a highly effective therapy, a subset of patients on infliximab will develop a loss of response to therapy.
View Article and Find Full Text PDFIntroduction: Immunoassays and liquid chromatography-tandem mass spectrometry assays are commonly employed in clinical laboratories for measurement of total testosterone in serum. Results obtained from either of these methodologies compare poorly due to differences in calibration and/or inadvertent detection of interfering substances by the immunoassays. Standardization efforts are underway, but recent studies indicate that accuracy remains an issue.
View Article and Find Full Text PDFBackground: Thyrotoxicosis attributable exclusively to triiodothyronine (T3) is, by necessity, caused by accidental or intentional ingestion of pharmaceutical preparations. The clinical presentation of T3 overdose appears to differ from classic thyroid storm.
Case: A 30-year-old female patient presented serially to the emergency department with headache, nausea and vomiting.
Background: The Binding Site immunonephelometric (IN) IgG subclass reagents (IgG1, IgG2, IgG3, IgG, BSIN) are used for assessment of both immunodeficiency and IgG4-related disease (IgG4-RD). In our laboratory, suspected analytic errors were noted in patients with increases in IgG4: The sum of the individual IgG subclasses was substantially greater than the measured total IgG concentrations (unlike samples with normal IgG4), and the IgG4 concentration was always less than the IgG2 concentration.
Methods: We developed a tryptic digest LC-MS/MS method to quantify IgG1, IgG2, IgG3, and IgG4 in serum.
Accurate determination of plasma renin activity (PRA) is essential for the development and maintenance of an effective screening program for primary aldosteronism (PA). PRA measurement can also be useful in the investigation of renal artery stenosis, syndrome of mineralocorticoid excess, Addison's disease, congenital adrenal hyperplasia, Bartter and Gitelman syndromes, and for inherited defects in the renin angiotensin aldosterone system (RAAS). We describe a semi-automated and simple method for the accurate and precise measurement of PRA from 500 μL of plasma (250 μL if blank subtraction is omitted, as discussed) using a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method for angiotensin I (AngI) in 96-well format.
View Article and Find Full Text PDFInsulin analysis is used in combination with glucose, C-peptide, beta-hydroxybutyrate, and proinsulin determination for the investigation of adult hypoglycemia. The most common cause is the administration of too much insulin or insulin secretagogue to a diabetic patient or inadequate caloric intake after administration of either. Occasionally there is a question as to whether hypoglycemia has been caused by an exogenous insulin-whether by accident, intent, or even malicious intent.
View Article and Find Full Text PDFAccurate determination of serum and plasma aldosterone is essential for screening, diagnosis, and subtype classification of primary aldosteronism (PA). Its measurement is also used in the investigation of adrenal incidentaloma, adrenal carcinoma, Addison's disease, congenital adrenal hyperplasia, renal artery stenosis, and renal tubular channelopathies. We describe a simple and robust method for the accurate and precise measurement of aldosterone in serum or plasma using liquid chromatography and tandem mass spectrometry (LC-MS/MS).
View Article and Find Full Text PDFPlasma renin activity (PRA) is essential for the screening and diagnosis of primary aldosteronism (PA), a form of secondary hypertension, which affects approximately 100 million people worldwide. It is commonly determined by radioimmunoassay (RIA) and, more recently, by relatively low-throughput LC-MS/MS methods. In order to circumvent the negative aspects of RIAs (radioisotopes, cross-reactivity) and the low throughput of LC-MS based methods, we have developed a high-throughput immuno-MALDI (iMALDI)-based assay for PRA determination using an Agilent Bravo for automated liquid handling and a Bruker Microflex LRF instrument for MALDI analysis, with the goal of implementing the assay in clinical laboratories.
View Article and Find Full Text PDF