This study aimed to estimate the prevalence of musculoskeletal disorders and rheumatic diseases among the indigenous Qom (Toba) population in the city of Rosario, Santa Fe, Argentina. An analytical cross-sectional study using methodology of the Community Oriented Program for the Control of Rheumatic Diseases (COPCORD) was performed. Subjects ≥18 years of age were interviewed by advanced students of medicine and nursing, bilingual translator-facilitators, and coordinators.
View Article and Find Full Text PDFConnecting fluorescence signals with anatomic structures enhances our ability to monitor biologic processes in mice. Here, we present a semiautomated approach to correlate two-dimensional (2D) noninvasive near-infrared fluorescence (NIRF) imaging with three-dimensional (3D), high-resolution, flat-panel volume computed tomography (fpVCT). We developed an algorithm to colocalize fluorescence signals of NIRF-labeled antibodies directed against matriptase and urokinase plasminogen activator receptor (uPAR) to orthotopic carcinomas in mice visualized by fpVCT.
View Article and Find Full Text PDFThe purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions.
View Article and Find Full Text PDFNoninvasive methods are strongly needed to detect and quantify not only tumor growth in murine tumor models but also the development of vascularization and necrosis within tumors. This study investigates the use of a new imaging technique, flat-panel detector volume computed tomography (fpVCT), to monitor in vivo tumor progression and structural changes within tumors of two murine carcinoma models. After tumor cell inoculation, single fpVCT scans of the entire mice were performed at different time points.
View Article and Find Full Text PDFThe renal cell carcinoma (RCC) is extremely resistant to chemotherapy and radiotherapy. The prognosis of patients with metastatic RCC still remains poor, the median survival is less than 12 months. Therefore, new therapeutic options are desirable.
View Article and Find Full Text PDFBackground: Although modern chemotherapy of stage IV advanced colorectal cancer (CRC) has impressively improved overall survival, the response of the primary tumor has not been studied because surgical resection of the primary continues to be the standard procedure in stage IV CRC.
Aim: Long-term follow-up of the primary in patients with stage IV CRC under chemotherapy.
Methods And Results: Here we report on the histological changes in the primary tumor in four patients suffering from stage IV CRC.
Skeletal metastasis is an important cause of mortality in patients with breast cancer. Hence, animal models, in combination with various imaging techniques, are in high demand for preclinical assessment of novel therapies. We evaluated the applicability of flat-panel volume computed tomography (fpVCT) to noninvasive detection of osteolytic bone metastases that develop in severe immunodeficient mice after intracardial injection of MDA-MB-231 breast cancer cells.
View Article and Find Full Text PDFAfter cystectomy two principal types of urinary diversion are used for the surgical reconstruction of the urinary tract: incontinent and continent. In the continent type of urinary diversion, a differentiation must be made between those with and without catheterization for voiding. Besides urothelial cancer other reasons for urinary diversion include neurogenic bladder palsy (connatal or acquired) due to meningomyelocele or connatal diseases like bladder exstrophy.
View Article and Find Full Text PDFRapid progress in exploring the human and mouse genome has resulted in the generation of a multitude of mouse models to study gene functions in their biological context. However, effective screening methods that allow rapid noninvasive phenotyping of transgenic and knockout mice are still lacking. To identify murine models with bone alterations in vivo, we used flat-panel volume computed tomography (fpVCT) for high-resolution 3-D imaging and developed an algorithm with a computational intelligence system.
View Article and Find Full Text PDFThe multiparametric molecular cell and tissue analysis in vitro and in vivo is characterized by rapid progress in the field of image generation technologies, sensor biotechnology, and computational modeling. Fascinating new potentials in unraveling the detailed functions of single cells, organs, and whole organisms are presently emerging and permit the close monitoring i.e.
View Article and Find Full Text PDFBackground Context: Image quality and implant detectability by conventional imaging methods are suboptimal for perioperative spinal diagnostics, primarily limited by implant-related artifacts.
Purpose: To evaluate the imaging quality of various intervertebral spacers examined by flat-panel detector-based volumetric computed tomography (FD-VCT) versus magnetic resonance imaging (MRI).
Study Design/setting: A preclinical comparative study on an experimental porcine model.
Diagnosis of primary spindle cell tumors of the spleen is challenging because of the limited immunologic and cytogenetic characterization of this rare entity. We report a case of primary follicular dendritic cell (FDC) sarcoma of the spleen in a 44-year-old woman. Indications for FDC included positive staining for CD21, Ki-M4P, CD14, and fascin.
View Article and Find Full Text PDFObjectives: The aim of this study was to compare the image performance of silicon-based flat-panel-detector-based volumetric computed tomography (fpVCT) to multislice spiral computed tomography (MSCT) for the visualization and detail detectability of skeletal structures in rodents of different development stages.
Materials And Methods: Rodents of different development stages were imaged with fpVCT (GE prototype with circular gantry with two 1024 x 1024, 200-microm pixel size, amorphous silicon/Cesium lodid (Csl) flat-panel detector) and eight-slice MSCT (LightSpeed Ultra). Imaging parameters (80 kVp, 100 mA) and the position of the rodents were identical in both techniques.
Introduction: Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs).
View Article and Find Full Text PDFThe goal of this study was to evaluate the performance of a computer-aided detection (CAD) system in full-field digital mammography (Senographe 2000D, General Electric, Buc, France) in finding out carcinomas depending on the parenchymal density. A total of 226 mediolateral oblique (MLO) and 186 craniocaudal (CC) mammographic views of histologically proven cancers were retrospectively evaluated with a digital CAD system (ImageChecker V2.3 R2 Technology, Los Altos, CA, USA).
View Article and Find Full Text PDFClin Oral Investig
September 2006
The flat panel-based volume computed tomography (fpVCT) is a new CT device applicable for experimental, three-dimensional evaluation of teeth at a resolution of about 150 microm in the high contrast region. The aim of this study was to investigate whether fpVCT was suitable for quantification of the volumes of dental hard tissues and the root canal system to establish a new method for morphological studies. Fifty-two extracted third molars (maxillary: 31, mandibular: 21) were examined with a prototype of an fpVCT using a volumetry algorithm at different levels according to the radiographic density of enamel and dentine.
View Article and Find Full Text PDFContrast-enhanced dynamic MR mammography can provide important additional diagnostic information when performed for certain indications. When suspicious lesions are identified on MR mammography and cannot be reproduced using other imaging modalities, a decision must be made as to its management, i. e.
View Article and Find Full Text PDFThe object of this study was to determine the performance of a computer-aided detection system in full-field digital mammography (Senographe 2000D, General Electric, Buc, France) in detecting carcinomas in breasts in dependence of the initial Breast Imaging Reporting and Data System (BI-RADS) categories. A total of 226 mediolateral oblique (MLO) and 186 craniocaudal (CC) view mammograms of histologically proven cancers were retrospectively evaluated with a primary digital computer-aided detection system (Image Checker V2.3; R2 Technology, Los Altos, CA).
View Article and Find Full Text PDFPurpose: Successful endodontic diagnostics and therapy call for adequate depiction of the root canal anatomy with multimodal diagnostic imaging. The aim of the present study is to evaluate visualization of the endodont with flat-panel detector volume CT (FD-VCT).
Materials And Methods: 13 human teeth were examined with the prototype of a FD-VCT.
Purpose: To evaluate the usefulness of a computer-aided detection (CAD) system in full-field digital mammography in correlation to tumor histology.
Material And Methods: A total of 476 patients (226 patients with histologically proven malignant tumors, 250 healthy women) took part in this study. The mammograms were studied retrospectively, using the CAD system Image Checker.
The Breast Imaging Reporting and Data System (BI-RADS) of the American College of Radiology (ACR) is a tool created to reduce variability in the terminology used in mammographic reports. An illustration of mammographic examples from our institution interpreted according to the BI-RADS lexicon of the American College of Radiology (ACR) is presented. A literature review concerning the usefulness and limitations of the BI-RADS lexicon is given.
View Article and Find Full Text PDFPurpose: To compare image quality of single-slice spiral CT (SSCT) and multislice spiral CT (MSCT) in the diagnosis and classification of calcaneal fractures and to present a rapid and precise algorithm for the classification system of Stuermer.
Materials And Methods: In 102 patients with 124 calcaneal fractures, spiral CT was performed, in 82 cases as SSCT with a slice thickness (SD) of 3 mm, a table speed (TS) of 3 - 4 mm/rot and an increment of 1.5 mm.
Purpose: To determine the performance of an a-Si/CsJ flat-panel detector-based volumetric computed tomography (VCT) prototype in volumetry of synthetic nodules in a pulmonary phantom, and to assess VCT accuracy in the assessment of hypothetic tumor growth rates based on predefined tumor doubling times.
Methods: The true volumes of 50 synthetic nodules (diameter range = 1.36 - 5.
Several mechanisms of development of hepatocellular carcinoma (HCC) in patients with liver cirrhosis have been discussed. One hypothesis suggests that the somatic stem cells of the liver, the so-called oval cells, may undergo malignant transformation. Oval cells are derived from the biliary cells of the canal of Hering and are characterized by c-kit-positivity, the transmembrane receptor of stem cell factor.
View Article and Find Full Text PDF