This work investigates the micellar titration of phenytoin (a weakly acidic drug) with cetyltrimethylammonium hydroxide (CTAH) to form a hydrophobic ion-pair to enhance oil solubility of phenytoin, followed by an effort to formulate nanoemulsion that could potentially prevent precipitation of phenytoin at physiological pH. The ion-pair formulated in nanoemulsion was evaluated for in vitro precipitation during serial dilution at physiological pH. The formation of ion-pair during titration was explained in context of pH-solubility data.
View Article and Find Full Text PDFA phase I trial (NCT03447314; 204686) evaluated the safety and efficacy of GSK1795091, a Toll-like receptor 4 (TLR4) agonist, in combination with immunotherapy (GSK3174998 [anti-OX40 monoclonal antibody], GSK3359609 [anti-ICOS monoclonal antibody], or pembrolizumab) in patients with solid tumors. The primary endpoint was safety; other endpoints included efficacy, pharmacokinetics, and pharmacodynamics (PD). Manufacturing of GSK1795091 formulation was modified during the trial to streamline production and administration, resulting in reduced PD (cytokine) activity.
View Article and Find Full Text PDFThe loss of active substance, both small and large molecules, from sterile liquid drug products after contact with an administration kit has been extensively reported in the literature. This loss has been reported to be caused by incompatibility of the active substances with the contact surfaces of the administration kit and adsorption or sticking of the active substance to the surfaces of the administration kit. This paper investigates the mechanism for loss of a highly potent active substance based on the type and design of the administration kit.
View Article and Find Full Text PDFThe aim of this work was to identify stable topical platform cream formulations (placebo creams without active drug substance) using the quality attributes of cream consistency, droplet size distribution (<1 μm), and separation or instability index of <0.1 to accelerate the development of topical cream drug product. The formulations were developed with six emulsifier systems that were screened in three different solvent systems across a range of emulsifier ratios.
View Article and Find Full Text PDFThis study investigates the influence of surfactant sodium lauryl sulfate (SLS) on the solubility of poorly-water soluble drug substances, model Compound X and Compound Y, used in a fixed dose combination oral solid dosage form. To determine the impact of SLS concentration on the solubility of compounds X and Y, we experimentally determined the critical micelle concentration (CMC) of SLS in water, simulated gastric fluid (SGF), and fed state simulated intestinal fluid (FeSSIF) in the presence of Compound X and Compound Y using UV/Visible spectrophotometry at 25°C. The aggregation of SLS was characterized by calculating the standard Gibbs free energy of micellization in all the media investigated.
View Article and Find Full Text PDFThe packaging presentation of oral liquid pediatric medicines is a critical step in maintaining chemical and physical stability, compliance, adherence, and proper handling by the target patient population, guardians, caregivers, and health-care professionals. The common packaging presentations for commercial oral liquid pediatric drug products are glass bottle, plastic bottle, sachet, and stick pack configurations. The type of pack presentation selected is driven by the quality target product profile (QTPP) that is designed around the physicochemical properties of the drug substance and the desired drug product suitability for the target population.
View Article and Find Full Text PDFPiezoelectric-excited millimeter-sized cantilever (PEMC) biosensors were fabricated and functionalized with immunoglobulin M (IgM) for the detection of Cryptosporidium parvum oocyst in a flow configuration at 1 mL/min. The detection of 100, 1000, and 10,000 oocysts/mL was achieved with a positive sensor response in less than 1 min. Bovine serum albumin (BSA) was used as a blocking agent in each experiment and was shown to eliminate non-specific binding.
View Article and Find Full Text PDFPiezoelectric-excited millimeter-sized cantilever (PEMC) sensors immobilized with antibody specific to Escherichia coli (EC) 0157:H7 is used to detect EC at 1 cell/mL in 1 mL and 1 L samples in a batch and flow mode, respectively. Two sensor designs were used. The first design (PEMC-a) has both the piezoelectric and non-piezoelectric layer anchored, while in the second design (PEMC-b) had only the piezoelectric layer anchored.
View Article and Find Full Text PDFRapid (approximately 10 min) measurement of very low concentration of pathogens (approximately 10 cells/mL) and protein (approximately fg/mL) has widespread use in medical diagnostics, monitoring biothreat agents, and in a broader context as a research method. For low-level pathogen, we currently use culture enrichment methods and, thus, rapid analysis is not possible. For low protein concentration, no direct method is currently available.
View Article and Find Full Text PDFA sensitive and reliable method for the detection of Bacillus anthracis (BA; Sterne strain 7702) spores in presence of large amounts of Bacillus thuringiensis (BT) and Bacillus cereus (BC) is presented based on a novel PZT-anchored piezoelectric excited millimeter-sized cantilever (PAPEMC) sensor with a sensing area of 1.5 mm2. Antibody (anti-BA) specific to BA spores was immobilized on the sensing area and exposed to various samples of BA, BT, and BC containing the same concentration of BA at 333 spores/mL, and the concentration of BT + BC was varied in concentration ratios of (BA:BT + BC) 0:1, 1:0, 1:1, 1:10, 1:100, and 1:1000.
View Article and Find Full Text PDFPiezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 4 mm2 were fabricated. An antibody specific to Escherichia coli (anti-E. coli) O157:H7 was immobilized on PEMC sensors, and exposed to samples containing E.
View Article and Find Full Text PDFIn this paper, we describe a new modality of measuring human serum albumin (HSA) adsorption continuously on CH3-, COOH-, and OH-terminated self-assembled monolayers (SAMs) of C11-alkanethiols and the direct quantification of the adsorbed amount. A gold-coated piezoelectric-excited millimeter-sized cantilever (PEMC) sensor of 6-mm2 sensing area was fabricated, where resonant frequency decreases upon mass increase. The resonant frequency in air of the detection peak was 45.
View Article and Find Full Text PDFPiezoelectric-excited millimeter-sized cantilever (PEMC) sensors of 4mm(2) sensing area were immobilized with antibody specific to Bacillus anthracis (anti-BA) spores or bovine serum albumin (anti-BSA). Detection of pathogen (Bacillus anthracis (BA) at 300 spores/mL) and BSA (1 mg/mL) were investigated under both stagnant and flow conditions. Two flow cell designs were evaluated by characterizing flow-induced resonant frequency shifts.
View Article and Find Full Text PDFBiosens Bioelectron
July 2006
To enhance the mass change sensitivity of the resonating piezoelectric-excited millimeter-sized cantilever (PEMC) sensors, we reduced its length and eliminated one layer of its composite structure. As a result the mass sensitivity of the second flexural mode increased by two orders of magnitude (from 10(-9) to 10(-11)g/Hz) and the resonant frequency increased by more than 5 kHz. We demonstrate the effects of modification by detecting a model pathogen Group A Streptococcus (GAS) at 700 cells/mL.
View Article and Find Full Text PDFIn this paper, we describe a new method of measuring alkanethiol monolayer formation on a gold surface. A gold-coated millimeter-sized rectangular-shaped lead zirconate titanate (PZT) cantilever of dimensions 3.5 x 2 x 0.
View Article and Find Full Text PDFBiosens Bioelectron
October 2005
A composite self-excited PZT-glass cantilever (4mm in length and 2mm wide) was fabricated and used to measure the binding and unbinding of model proteins. A key feature of the cantilever is that its resonant frequency is dependent on its mass. The fabricated cantilever has mass change sensitivity in liquid of 7.
View Article and Find Full Text PDFPiezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 2.48 mm2 were fabricated. Antibody specific to Bacillus anthracis (BA, Sterne strain 7702) spores was immobilized on PEMC sensors, and exposed to spores (300 to 3x10(6) spores/mL).
View Article and Find Full Text PDFBiosens Bioelectron
September 2005
Composite self-excited PZT-glass cantilevers (5 and 3 mm in length, 1.8 and 2.0 mm wide) were fabricated and their resonance characteristics were determined in air and at 1 mm liquid immersion.
View Article and Find Full Text PDFA composite self-excited millimeter-sized lead zirconate titanate (PZT) glass cantilever (2 mm x 1.8 mm; sensing area of 6 mm2) was fabricated for the detection of Escherichia coli (E. coli) O157:H7.
View Article and Find Full Text PDF