Introduction: The objective of the present study was to describe the experience of the Blood and Tissues Bank of Aragon with the Reveos® Automated Blood Processing System and Mirasol® Pathogen Reduction Technology (PRT) System, comparing retrospectively routine quality data obtained in two different observation periods.

Methods: Comparing quality data encompassing 6,525 blood components from the period 2007-2012, when the semi-automated buffy coat method was used in routine, with 6,553 quality data from the period 2014-2019, when the Reveos system and subsequently the Mirasol system were implemented in routine.

Results: Moving from buffy coat to Reveos led to decreased discard rates of whole blood units (1.

View Article and Find Full Text PDF

Background And Objectives: Applying pathogen reduction technologies (PRT) to platelets can extend their shelf life from 5 to 7 days, but there have been few systematic studies of the repercussions of such technologies on outdate rates.

Material And Methods: The benefits in terms of outdate rates of applying PRT to platelets are studied via a mathematical simulation. Specifically, statistical methods are used to determine the daily production rate needed to meet demand while not exceeding a maximum amount set as a result of limitations on donations and while assuring a minimum daily stock.