Narrow band ultraviolet B (NB UVB) radiation doses are administered during phototherapy for various dermatological ailments. Precise quantification of these doses is vital because the absorbed irradiation can cause adverse photochemical reactions which can lead to potential phototherapeutic side effects. The paper presents development of diacetylene based dosimeter for the determination of therapeutic NB UVB doses during phototherapy.
View Article and Find Full Text PDFAccurate dose measurement tools are needed to evaluate the radiation dose delivered to patients by using modern and sophisticated radiation therapy techniques. However, the adequate tools which enable us to directly measure the dose distributions in three-dimensional (3D) space are not commonly available. One such 3D dose measurement device is the polymer-based dosimeter, which changes the material property in response to radiation.
View Article and Find Full Text PDFPurpose: To investigate the feasibility of three-dimensional (3D) dose measurements near thin high-Z materials placed in a water-like medium by using a polymer gel dosimeter (PGD) when the medium was irradiated with high energy photon beams.
Methods: PGD is potentially a useful tool for this application because it can record the dose around a small object made of a high-Z material in a continuous 3D medium. In this study, the authors manufactured a methacrylic acid-based normoxic PGD, nMAG.
Background: Following gamma knife (GK) therapy for intracranial arteriovenous malformations (AVMs), obliteration of the nidus occurs over several years. During this period, complications like rebleeding have been attributed to early draining vein occlusion.
Objective: To evaluate if shielding the draining vein(s) during GK therapy prevents early draining vein obliteration and complications following GK therapy.
The purpose of this study was to validate the newly designed acrylic phantom for routine dosimetric purpose in radiotherapy. The phantom can be used to evaluate and compare the calculated dose and measured dose using film and gel dosimetric methods. In this study, a doughnut-shaped planning target volume (8.
View Article and Find Full Text PDFPurpose: The photoneutron contamination problem was encountered due to laminated barrier wall and short maze. The purpose of this study was to report our experience in evaluating the photoneutron contamination during radiation safety survey and solution.
Methods: The photoneutron contamination measurement was carried out in Elekta Synergy-S high-energylinear accelerator for 15MV beam.
Purpose: To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.
Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for eXtend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, acquiring a stereotactic computed tomography (CT) scan.
One of treatment planning techniques with Leksell GammaPlan (LGP) for Gamma Knife stereotactic radiosurgery (GKSRS) uses multiple matrices with multiple dose prescriptions. Computational complexity increases when shots are placed in multiple matrices with different grid sizes. Hence, the experimental validation of LGP calculated dose distributions is needed for those cases.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2010
Verification of the dose calculation model and the software used for treatment planning is an important step for accurate radiation delivery in radiation therapy. Using BANG3 polymer gel dosimeter with a 3 Tesla magnetic resonance imaging (MRI) scanner, we examined the accuracy of TomoTherapy treatment planning and radiation delivery. We evaluated one prostate treatment case and found the calculated three-dimensional (3D) dose distributions agree with the measured 3D dose distributions with an exception in the regions where the dose was much smaller (25% or less) than the maximum dose (2.
View Article and Find Full Text PDFPurpose: Interstitial brachytherapy (IBT) is used as an alternative to intracavitary radiotherapy in the management of cervical carcinoma. We have devised a new technique called interstitial brachytherapy guided intensity modulated radiotherapy (IBGIMRT) which can potentially reduce doses to organs at risk (OaRs). It utilizes IMRT planning on the target volume (TV) defined by implantation of IBT needles.
View Article and Find Full Text PDFCardiac toxicity is an important concern in tangential field breast radiotherapy. In this study, the impact of three different breathing conditions on the dose to surrounding normal structures such as heart, ipsilateral lung, liver and contralateral breast has been assessed. Thirteen patients with early breast cancer who underwent conservative surgery (nine left-sided and four right-sided breast cancer patients) were selected in this study.
View Article and Find Full Text PDFA commercial metal oxide silicon field effect transistor (MOSFET) dosimeter of model TN502-RD has been characterized for its linearity, reproducibility, field size dependency, dose rate dependency, and angular dependency for Cobalt-60 (60Co), 6-MV, and 15-MV beam energies. The performance of the MOSFET clearly shows that it is highly reproducible, independent of field size and dose rate. Furthermore, MOSFET has a very high degree of linearity, with r-value>0.