Publications by authors named "Gomez-Ros J"

Proton therapy is an external radiotherapy using proton beams with energies between 70 and 230 MeV to treat some type of tumours with outstanding benefits, due to its energy transfer plot. There is a growing demand of facilities taking up small spaces and Compact Proton Therapy Centers (CPTC), with one or two treatment rooms, supposing the technical response of manufacturers to this request. A large amount of stray radiation is yielded in the interaction of proton beam used in therapy, neutrons mainly, hence, optimal design of shielding and verifications must be carried out in commissioning phases.

View Article and Find Full Text PDF

This contribution describes a kinetic model attempting to reproduce the response of the thermoluminescent material LiF:Mg,Cu,P when it is irradiated to absorbed dose values in the kGy range. The modelling is based on the hypothesis of a relationship between the irradiation time (i.e.

View Article and Find Full Text PDF

Proton therapy (PT) is an external radiotherapy using proton beams with energies between 70 and 230 MeV to treat some type of tumours with outstanding benefits, due to its energy transfer plot. There is a growing demand of facilities taking up small spaces and Compact Proton Therapy Centers (CPTC), with one or two treatment rooms, supposing the technical response of manufacturers to this request. A large amount of stray radiation is produced in the interaction of protons used in therapy, neutrons mainly, hence, optimal design of shielding and verifications must be carried out in commissioning stages.

View Article and Find Full Text PDF

Working Group (WG) 6 'Computational Dosimetry' of the European Radiation Dosimetry Group promotes good practice in the application of computational methods for radiation dosimetry in radiation protection and the medical use of ionising radiation. Its cross-sectional activities within the association cover a large range of current topics in radiation dosimetry, including more fundamental studies of radiation effects in complex systems. In addition, WG 6 also performs scientific research and development as well as knowledge transfer activities, such as training courses.

View Article and Find Full Text PDF

Deconvolution analysis of the thermoluminiscent (TL) glow curves proved to be a good complementary method to characterize the individual glow peaks by fitting their kinetic parameters. In this work, new software has been developed for the automatic deconvolution of TL glow curves, assuming either discrete or continuous distribution of trapping centres. The guess estimation of the kinetic parameters is done automatically and can be manually modified, thus allowing the use of the software for routine, processing a large number of measurements, as well as for research purposes.

View Article and Find Full Text PDF

CSYP (CYlindrical SPectrometer) is a directional neutron spectrometer based on a single moderator embedding multiple thermal neutron detectors. Similarly to Bonner Spheres, CYSP responds from thermal up to GeV neutrons and the spectrum is obtained via few-channel unfolding methods. CYSP has the shape of a polyethylene cylinder with diameter 50 cm and height 65 cm.

View Article and Find Full Text PDF

This article describes the purpose, the proposed problems and the reference solutions of an international comparison on neutron spectra unfolding in Bonner spheres spectrometry, organised within the activities of EURADOS working group 6: computational dosimetry. The exercise considered four realistic situations: a medical accelerator, a workplace field, an irradiation room and a skyshine scenario. Although a detailed analysis of the submitted solutions is under preparation, the preliminary discussion of some physical aspects of the problem, e.

View Article and Find Full Text PDF

Radiation-resistant, gamma-insensitive, active thermal neutron detectors were developed to monitor the thermal neutron cavity of the E_LIBANS project. Silicon and silicon carbide semiconductors, plus vented air ion chambers, were chosen for this purpose. This communication describes the performance of these detectors, owing on the results of dedicated measurement campaigns.

View Article and Find Full Text PDF

The e_LiBANS project aims at producing intense thermal neutron fields for diverse interdisciplinary irradiation purposes. It makes use of a reconditioned medical electron LINAC, recently installed at the Physics Department and INFN in Torino, coupled to a dedicated photo-converter, developed within this collaboration, that uses (γ,n) reaction within high Z targets. Produced neutrons are then moderated to thermal energies and concentrated in an irradiation volume.

View Article and Find Full Text PDF

HOTNES (HOmogeneous Thermal NEutron Source) is a thermal neutron irradiation facility with extended and very uniform irradiation area. A Am-B radionuclide neutron source with nominal strenght 3.5×10 s is located on bottom of a large cylindrical cavity (30cm diameter, 70cm in height) delimited by polyethylene walls.

View Article and Find Full Text PDF

Exposure to radiation is a potential hazard to humans and the environment. The Fukushima accident reminded the world of the importance of a reliable risk management system that incorporates the dose received from radiation exposures. The dose to humans from exposure to radiation can be quantified using a well-defined system; its environmental equivalent, however, is still in a developmental state.

View Article and Find Full Text PDF

This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially advantageous for neutron field characterisation and workplace monitoring in neutron-producing facilities. One of the devices has spherical geometry and nearly isotropic response, the other one has cylindrical symmetry and it is only sensitive to neutrons incident along the cylinder axis.

View Article and Find Full Text PDF

Monte Carlo (MC) methods are numerical simulation techniques that can be used to extend the scope of calibrations performed in in vivo monitoring laboratories. These methods allow calibrations to be carried out for a much wider range of body shapes and sizes than would be feasible using physical phantoms. Unfortunately, nowadays, this powerful technique is still used mainly in research institutions only.

View Article and Find Full Text PDF

At the CIEMAT whole-body counter, a low-energy germanium detector is used for the in vivo assessment of (131)I activity in thyroid, mainly for the individual monitoring programmes of workers. The detector is calibrated with a cylindrical neck phantom made of polymethyl methacrylate that mimics the neck of an adult, containing a vial with a radioactive solution. For an accurate activity assessment, it is necessary to perform the calibration of the detector with phantoms that closely reproduce the anatomy of a real person.

View Article and Find Full Text PDF

A new thermal neutron irradiation facility based on an (241)Am-Be source embedded in a polyethylene moderator has been designed, and is called ETHERNES (Extended THERmal NEutron Source). The facility shows a large irradiation cavity (45 cm × 45 cm square section, 63 cm in height), which is separated from the source by means of a polyethylene sphere acting as shadowing object. Taking advantage of multiple scattering of neutrons with the walls of this cavity, the moderation process is especially effective and allows obtaining useful thermal fluence rates from 550 to 800 cm(-2) s(-1) with a source having nominal emission rate 5.

View Article and Find Full Text PDF

This communication describes a recently developed single-exposure neutron spectrometer, based on multiple active thermal neutron detectors located within a moderating sphere, which have been developed jointly by CIEMAT (Spain), INFN (Italy) and Politecnico di Milano (Italy) in the framework of Italian and Spanish collaboration projects. The fabricated prototypes permit to achieve spectrometric resolution with nearly isotropic response for neutron with energies from thermal to 100-200 MeV, thus being able to characterise the complete neutron spectrum in only one exposure by unfolding the measured responses of the detectors. This makes it especially advantageous for characterising neutron fields and workplace monitoring purposes in neutron-producing facilities.

View Article and Find Full Text PDF

This communication presents the main results about the design and in-house fabrication of a new solid-state neutron detector, which produces a DC output signal proportional to the thermal neutron fluence rate. The detector has been developed within the framework of the 3-y project NESCOFI@BTF of INFN (CSN V). Due to its sensitivity, photon rejection, low cost and minimum size, this device is suited to be used in moderator-based spectrometers.

View Article and Find Full Text PDF

In the framework of the NESCOFI@BTF project of the Italian Institute of Nuclear Physics, different types of active thermal neutron sensors were studied by coupling semiconductor devices with a suitable radiator. The objective was to develop a detector of small dimensions with a proper sensitivity to use at different positions in a novel moderating assembly for neutron spectrometry. This work discusses the experimental activity carried out in the framework of the ERINDA program (PAC 3/9 2012) to characterise the performance of a thermal neutron pulse detector based on (6)Li.

View Article and Find Full Text PDF

NESCOFI@BTF is a 3-y project (2011-13) supported by the Scientific Commission 5 of INFN (Italy). The target is the development of neutron spectrometers similar to the Bonner spheres, in terms of response energy interval and accuracy, but able to determine the neutron spectrum in only one exposure. These devices embed multiple (10 to 30) thermal neutron detectors (TNDs) within a single moderator.

View Article and Find Full Text PDF

Purpose: To calculate absorbed doses due to neutrons in 87 organs/tissues for anthropomorphic phantoms, irradiated in position supine (head first into the gantry) with orientations anteroposterior (AP) and right-left (RLAT) with a 18 MV accelerator. Conversion factors from monitor units to μGy per neutron in organs, equivalent doses in organs/tissues, and effective doses, which permit to quantify stochastic risks, are estimated.

Methods: MAX06 and FAX06 phantoms were modeled with MCNPX and irradiated with a 18 MV Varian Clinac 2100C/D accelerator whose geometry included a multileaf collimator.

View Article and Find Full Text PDF

In this work, the ambient dose equivalent, H*(10), due to neutrons outside three bunkers that house a 15- and a 18-MV Varian Clinac 2100C/D and a 15-MV Elekta Inor clinical linacs, has been calculated. The Monte Carlo code MCNPX (v. 2.

View Article and Find Full Text PDF

Background And Purpose: Small radiation beams (<4 cm width) are being increasingly used in the delivery of advanced techniques as Intensity Modulated Radiotherapy (IMRT) and Stereotactic Radiosurgery (SRS). Dose measurements in small beams present challenges not encountered for larger beams. A postal audit with Thermoluminiscent Dosimeters (TLD) was developed to check the doses in small photon beams.

View Article and Find Full Text PDF

In this work, the dose equivalent due to photoneutrons and the neutron spectra in tissue was calculated for various linacs (Varian Clinac 2100C, Elekta Inor, Elekta SL25 and Siemens Mevatron KDS) operating at energies between 15 and 20 MV, using the Monte Carlo code MCNPX (v. 2.5).

View Article and Find Full Text PDF
Article Synopsis
  • The CONRAD Work Package 4 focused on Computational Dosimetry, collaborating on topics like internal dosimetry and radiation fields at workplaces.
  • WP4 conducted an international comparison on eight problems related to experimental data, summarizing findings across various dosimetry techniques.
  • Results from three specific problems centered on stochastic uncertainties, with detailed papers and outcomes set to be showcased at the WP4 Final Workshop Proceedings.
View Article and Find Full Text PDF

In the frame of the EU Coordination Action CONRAD (coordinated network for radiation dosimetry), WP4 was dedicated to work on computational dosimetry with an action entitled 'Uncertainty assessment in computational dosimetry: an intercomparison of approaches'. Participants attempted one or more of eight problems. This paper presents the results from problems 4-8-dealing with the overall uncertainty budget estimate; a short overview of each problem is presented together with a discussion of the most significant results and conclusions.

View Article and Find Full Text PDF