Background: Medication errors are a common problem in hospitals and a major driver of adverse patient outcomes. Barcode verification technology is a promising strategy to help ensure safe medication preparation practices.
Objectives: The objectives of this study were (i) to assess the effects of a barcode-assisted medication preparation and administration system regarding the rate of medication preparation errors and (ii) to compare the time spent on medication preparation tasks by medical staff.
Annu Int Conf IEEE Eng Med Biol Soc
July 2019
Pulse wave velocity has emerged as important diagnostic parameter due to its association with various cardiovascular disorders, such as hypertension, vascular aging, and atherosclerosis. Long-term monitoring of pulse wave velocity can be beneficial in carrying out accurate diagnosis of the underlying conditions or even for an early prediction of cardiovascular diseases. Doppler radar has emerged as a promising technology for contact-less monitoring and assessment of physiological parameters.
View Article and Find Full Text PDFZ Evid Fortbild Qual Gesundhwes
October 2019
Background: New technologies, such as bar-code scanning systems, have played a significant role in enhancing medication processes over recent years. Despite the documented benefits, integration, acceptance, and user opinion continue to play an important role in the successful implementation of such systems. To date no studies have been carried out in Switzerland to assess the attitude or acceptance of nurses towards electronically supported medication systems after implementation.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
September 2019
Aims: Supraventricular arrhythmia diagnosis using the surface electrocardiogram (sECG) is often cumbersome due to limited atrial signal quality. In some instances, use of esophageal electrocardiography (eECG) may facilitate the diagnosis. Here, we present a novel approach to reconstruct cardiac activation maps from eECG recordings.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
August 2018
The rapid progress of invasive therapeutic options for cardiac arrhythmias increases the need for accurate diagnostics. The surface electrocardiogram (ECG) is still the standard of noninvasive diagnostics but lacks atrial signal resolution. By contrast, esophageal electrocardiography (EECG) yields atrial signals of high amplitude and with a high signal-to-noise ratio.
View Article and Find Full Text PDFAn estimated 45 million persons in Europe are annually subjected to sleep-wake disorders. State-of-the-art polysomnography provides sophisticated insights into sleep (patho)physiology. A drawback of the method, however, is the obtrusive setting dependent on a clinical-based sleep laboratory with high operational costs.
View Article and Find Full Text PDFBackground: Prospective observational studies from Swiss university hospitals, focusing on the frequency of medication preparation and medication administration errors using direct observation, are still missing. To close this gap, we have conducted a scientific evaluation of an electronically assisted medication preparation and administration process in a Swiss university hospital. Aim: The aim of this study was to measure the frequency of medication preparation and medication administration errors in two units in a Swiss university hospital before the implementation of an electronically assisted medication preparation and administration process.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
April 2017
A new pseudo asynchronous level crossing analogue-to-digital converter (adc) architecture targeted for low-power, implantable, long-term biomedical sensing applications is presented. In contrast to most of the existing asynchronous level crossing adc designs, the proposed design has no digital-to-analogue converter (dac) and no continuous time comparators. Instead, the proposed architecture uses an analogue memory cell and dynamic comparators.
View Article and Find Full Text PDFPurpose: Paroxysmal atrial fibrillation (PAF) often remains undiagnosed. Long-term surface ECG is used for screening, but has limitations. Esophageal ECG (eECG) allows recording high quality atrial signals, which were used to identify markers for PAF.
View Article and Find Full Text PDFThorac Cardiovasc Surg
December 2016
Recent guidelines have recommended the addition of ablation in cardiac surgery for patients presenting with atrial fibrillation (AF). Currently available cryoablation devices use either nitrous oxide or argon gas as cooling agent. Our study aimed to compare success rates of two different devices currently available on the market and applied during concomitant cardiac surgery.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
December 2015
Asynchronous level crossing sampling analog-to-digital converters (ADCs) are known to be more energy efficient and produce fewer samples than their equidistantly sampling counterparts. However, as the required threshold voltage is lowered, the number of samples and, in turn, the data rate and the energy consumed by the overall system increases. In this paper, we present a cubic Hermitian vector-based technique for online compression of asynchronously sampled electrocardiogram signals.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
February 2016
Long-term electrocardiogram (ECG) signals might suffer from relevant baseline disturbances during physical activity. Motion artifacts in particular are more pronounced with dry surface or esophageal electrodes which are dedicated to prolonged ECG recording. In this paper we present a method called baseline wander tracking (BWT) that tracks and rejects strong baseline disturbances and avoids concurrent saturation of the analog front-end.
View Article and Find Full Text PDFLong-term electrocardiogram (ECG) often suffers from relevant noise. Baseline wander in particular is pronounced in ECG recordings using dry or esophageal electrodes, which are dedicated for prolonged registration. While analog high-pass filters introduce phase distortions, reliable offline filtering of the baseline wander implies a computational burden that has to be put in relation to the increase in signal-to-baseline ratio (SBR).
View Article and Find Full Text PDFLong-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e.
View Article and Find Full Text PDFBMC Complement Altern Med
February 2014
Background: Curcumin (CUR) is a dietary spice and food colorant (E100). Its potent anti-inflammatory activity by inhibiting the activation of Nuclear Factor-κB is well established.
Methods: The aim of this study was to compare natural purified CUR (nCUR) with synthetically manufactured CUR (sCUR) with respect to their capacity to inhibit detrimental effects in an in vitro model of oral mucositis.
Background: Ischemia monitoring cannot always be performed by 12-lead ECG. Hence, the individual performance of the ECG leads is crucial. No experimental data on the ECG's specificity for transient ischemia exist.
View Article and Find Full Text PDFThe emerging application of long-term and high-quality ECG recording requires alternative electrodes to improve the signal quality and recording capability of surface skin electrodes. The esophageal ECG has the potential to overcome these limitations but necessitates novel recorder and lead designs. The electrode material is of particular interest, since the material has to ensure conflicting requirements like excellent biopotential recording properties and inertness.
View Article and Find Full Text PDFBackground: Diagnosing supraventricular arrhythmias by conventional long-term ECG can be cumbersome because of poor p-waves. Esophageal long-term electrocardiography (eECG) has an excellent sensitivity for atrial signals and may overcome this limitation. However, the optimal lead insertion depth (OLID) is not known.
View Article and Find Full Text PDFDetection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria.
View Article and Find Full Text PDFBackground: The rise in the use of antibiotics has resulted in increasing health care costs and the emergence of resistant bacteria. Little is known about the general misuse of antibiotics in hospitalized children. We evaluated the utilization of antibiotics in a pediatric teaching hospital aiming to identify targets for improvement of prescription.
View Article and Find Full Text PDFThe most sensitive screening technique for genes that predispose patients for particular cancers is direct sequencing. However, sequencing of complex genes is technically demanding, costly and time-consuming. We have tested alternate screening techniques to find a fast sensitive method for detecting alterations of DNA in the large BRCA1 gene prior to sequencing.
View Article and Find Full Text PDFThe peptide hormone human calcitonin (hCT) has a marked tendency to aggregate in aqueous solutions, resulting in viscous and turbid dispersions consisting of long fibrils approximately 80 A in diameter. Both transmission (T-FTIR) and attenuated total reflection Fourier transform infrared (ATR-FTIR) experiments were applied on hCT adsorption and aggregation kinetics. By means of the surface sensitive ATR-FTIR spectroscopy at a hydrophobic/hydrophilic interface, early adsorption and aggregation steps of hCT could be followed in situ under real time conditions.
View Article and Find Full Text PDF