Rationale & Objective: Peritoneal dialysis (PD) solutions provide both clearance of uremic toxins and sodium and water. An intraperitoneal (IP) solution of icodextrin and glucose designed without the requirement for uremic toxin clearance could provide substantially greater sodium and water removal than PD solutions.
Study Design: We examined varying concentrations of icodextrin and dextrose IP solutions in rats.
J Clin Monit Comput
April 2012
The Tensys TL-200(®) noninvasive beat-to-beat blood pressure (BP) monitor displays continuous radial artery waveform as well as systolic, mean and diastolic BP from a pressure sensor directly over the radial artery at the wrist. It locates the site of maximal radial pulse signal, determines mean BP from maximal pulse waveform amplitude at optimal artery compression and then derives systolic and diastolic BP. We performed a cross-sectional study of TL-200 BP comparisons with contralateral invasive radial artery (A-Line) BP values in 19 subjects during an average 2.
View Article and Find Full Text PDFObjective: To assess the agreement between a novel approach of arterial and the pulmonary artery bolus thermodilution for measuring cardiac output in critically ill patients during aortic counterpulsation.
Methods: Eighteen male patients aged 37-80 years, undergoing preoperative insertion of an intra-aortic balloon pump (IABP) and elective coronary artery bypass grafting. A thin 1.
Clinical use of heart assist devices is often associated with thromboembolic complications. We hypothesized that platelets may be activated in patients receiving assist devices and examined expression of the platelet activation markers CD62, CD63, and thrombospondin using flow cytometry in eight patients with Novacor left ventricular assist system (LVAS) or Berlin Heart. Patients with end-stage heart failure had elevated expression of platelet activation markers before insertion of the assist device.
View Article and Find Full Text PDFStudy Objective: To compare cardiac index (CI) measurement by arterial pulse contour analysis using two different algorithms (CI(PC), CI(PCnew)) with pulmonary arterial thermodilution values (CI(PA)) so as to evaluate the difference between the conventional algorithm, CI(PC), and a new algorithm, CI(PCnew), that accounts for patients' individual aortic compliance.
Design: Prospective, clinical study.
Setting: Intensive care unit of a university hospital.
Objective: We hypothesized that measuring stroke volume variation (SVV) during mechanical ventilation by continuous arterial pulse contour analysis allows the accurate prediction and monitoring of changes in cardiac index (CI) in response to volume administration.
Design And Setting: Prospective study in an university hospital.
Patients: Twenty mechanically ventilated patients following cardiac surgery.
Study Objectives: A transpulmonary thermal-dye dilution (TDD) technique using cold indocyanine green dye was utilized to monitor cardiac index (CI) and preload in patients after heart transplantation. Preload, determined by intrathoracic blood volume index (ITBVI) and global end-diastolic volume index (GEDVI), was compared to central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP) and was correlated with stroke volume index (SVI).
Design: Prospective study.
Objective: To compare two thermodilution methods for the determination of cardiac output (CO)-thermodilution in the pulmonary artery (COpa) and thermodilution in the femoral artery (COa)-with each other and with CO determined by continuous pulse contour analysis (COpc) in terms of reproducibility, bias, and correlation among the different methods. Good agreement between the methods would indicate the potential of pulse contour analysis to monitor CO continuously and at reduced invasiveness.
Design: Prospective criterion standard study.
Objective: Since its clinical introduction, the Novacor left ventricular assist system (LVAS) has proved to be a reliable and safe method for bridging to cardiac transplantation. To find out whether univentricular assistance is sufficient in patients with severe global heart failure, multi organ monitoring using the COLD system was performed.
Methods: In seven patients (mean age 38.